CT PT analyzer HYVA-404
Tests for Current Transformer: Tests for Voltage Transformer: 1)Turns ratio test and phase angle error test |
1) CT nameplate check 2) CT parameters check in work burden 3) CT transient parameters analysis 4) CT ratio and phase error calibration 5) PT routine test |
1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13 2 Power supply: AC220V±10%,50Hz/60Hz±10% 3 Power output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output:300VA 6 Maximum knee voltage measurement:45kv 7 Current measurement: Range:0~10A (automatically change range in 0.1/0.4/2/10A) Error <±0.1%+0.01%FS 8 Voltage measurement: Range:0~200 V (automatically change range in 1V/10V/70V/200V) Error < ±0.1%+0.01%FS 9 Turns ratio measurement: Range :1~35000, 1~2000 error<0.05% 2000~5000 error>0.1% 5000~35000 error<0.2% 10 Phase measurement: error:±2min,resolution:0.01min 11 Coil resistance measurement: Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error< 0.2%RDG+0.02%FS Maximum resolution:0.1mΩ 12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree 13 CT Secondary burden: Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm 14 PT Secondary burden: Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range :1~35000, 1~5000 error<0.2% 5000~35000 error<0.5% 16 Saved data groups:>1000groups 17 Work condition: Temperature:-10℃~50℃, moist:≤90% 18 Size: 485mm×356mm×183mm 19 Weight: <15Kg |
Send product request
Other supplier products
HYDW grounding resistance tester | Application Type: 3A / 5A HYDW-grounding resistance tester is applied to measure the grounding resistance in power station or generator station ... | |
CT PT analyzer HYVA-404 | Introduction Tests for Current Transformer:1)Excitation curve and parameters test2)Turns ratio test3)Ratio and phase error test4)Polarity mark... | |
HYLB-601 instantaneous signal recorder | Introduction: HYLB-601 is an instantaneous signal recorder applied in industry signal analysis. It takes IPC as the core for data sample and proce... | |
HYYJ-502 insulating oil tester | Introduction Insulating oil tester 1 Breakdowntestofuser-defined 2 Prooftest 3 IEC60156/IS6792/BS5874test 4 ASTMD1816stand... | |
HYGK-303 Circuit Breaker Analyzer | Circuit breakeranalyzergeneralintroduction: ThiscircuitbreakertesterisworkingonIEC62771, thecircuitbreakeranalyzerhasanaccuratedisplayscreenandrota... |
Same products
48V 230VAC 5000W SOLAR INVERTER CHARGER (500VOC) | Seller: Suzhou Cosuper Energy Technology Co., Ltd | The Cosuper SPE5000S solar inverter charger is a combination of solar charger, battery inverter a... | |
1*8 Card-Type Fiber Optic Splitter | Seller: Hangzhou Tuolima Network Technologies Co., Ltd | Optical splitter is a part of passive components (also called optical passive components) in the ... | |
1*4 Mini Fiber Optic PLC Splitter | Seller: Hangzhou Tuolima Network Technologies Co., Ltd | 1 4 fiber optic splitteris a part of passive components (also called optical passive components) ... | |
1*4 Card-Type Fiber Optic Splitter | Seller: Hangzhou Tuolima Network Technologies Co., Ltd | Optical splitter is a part of passive components (also called optical passive components) in the ... | |
1*2 Mini Fiber Optic Splitter | Seller: Hangzhou Tuolima Network Technologies Co., Ltd | Optical splitter is a part of passive components (also called optical passive components) in the ... |