DO Signal (SIS) Input 24V DC 5A Safety Relay
These safety relay are suitable for the application of E-Stop button, safety gate and DO signal from SIS, with several contacts output.
The emergency stop safety relay can be operated in single or double channel mode, manual or automatic reset, and with the function of monitoring the short circuit between channels.
Features & Advantages of DO Signal (SIS) Input 24V DC 5A Safety Relay
Several contacts output
Low start-up inrush current
Parameter of DO SIS SignalInput 24V DC 5A Safety Relay
|
CZSR8001-3A1B |
CZSR8001-2A2B |
|
|
Supply voltage |
24V DC |
24V DC |
|
Voltage tolerance |
||
|
Current consumption |
≤90mA (24V DC) |
≤90mA (24V DC) |
|
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
|
Cable resistance |
≤15Ω |
≤15Ω |
|
Input devices |
DO signals |
DO signals |
|
Number of contacts |
3NO+1NC |
2NO+2NC |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
|
External contact fuse protection |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
|
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
|
|
Utilisation category |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
|
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
|
|
Switch-on delay |
≤300ms |
≤300ms |
|
Delay-on de-energisation |
≤30ms |
≤30ms |
|
Recovery time |
≤100ms |
≤100ms |
|
Supply short interruption |
20ms |
20ms |
|
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
|
Vibration |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
|
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
|
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
|
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
|
Relative humidity |
10%~90% |
10%~90% |
|
Overvoltage category |
Ⅲ |
Ⅲ |
|
Pollution degree |
2 |
2 |
|
Rated insulation voltage |
250V AC |
250V AC |
|
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
|
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
|
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
|
Safety integrity level |
SIL3 |
SIL3 |
|
Performance level |
PLe |
PLe |
|
Category |
If you want buy a high quality dc power surge protector, please choose Chenzhu!
Send product request
Other supplier products
| Low Power SPD | The low voltage surge protection deviceis designed to prevent transient surge conditions. T range SPD for low power supply is used for protecting 2... | |
| AC Power SPD | The surge protector is designed to prevent transient surge conditions. Large single surge events, such as lightning, can reach hundreds of thousand... | |
| Signal SPD | Electronic devices are always threatened by power surges and transients caused by power failures or nearby lightning strikes. Signal SPDsurge pr... | |
| CZ2000 Series Signal Conditioner | CZ2000 range signal conditioners use high-efficiency electromagnetic isolation technology to achieve reliable galvanic isolation among power supply... | |
| 40KA AC Power SPD | SPD for AC power; 220VAC, TN system, Single phase; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication Features & Adva... |
Same products
| Residential Energy Storage Inverters | Seller: Shenzhen Sinopoly New Energy Co., Ltd | Key Features of Residential Energy Storage Inverters Bidirectional Functionality Converts DC ... | |
| KYN61-40.5(Z) Removable Waterproof And Dustproof Metal Medium Voltage Switch Cabinet | Seller: QINGHANG ELECTRIC CO., LTD. | The removable waterproof and dustproof metal medium-voltage switchgear is a kind of power distrib... | |
| ABB General-Purpose Inverter ACS530 Series | Seller: Wuxi Jincheng Hairun Electric Co., Ltd | ACS530 is a member of ABB's compatible drive portfolio. Its rich built-in functions and compact d... | |
| IngersollRand Air Motors | Seller: 852050 | IngersollRand Air Motorsare available in a broad range of speeds, torques and power and are the m... | |
| ENERPAC BRC-Series Pull Cylinders | Seller: 852050 | BRC-Series Hydraulic Pull Cylindersinclude threads on the base, collar, and plunger for fixing at... |