N2XRY

German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts and in the open where better mechanical protection is required, or for higher tensile stress during installation and operation. Suitable for comparatively high ambient temperature due to high maximum permissible conductor temperature.Standard and ApprovalIEC 60502-1, VDE 0276-604, BS5467Cable Construction1- Solid or stranded, plain copper conductor- to DIN VDE 0295 cl. 1 or cl. 2, BS 6360 cl. 1 or cl. 2 and IEC 60228 cl. 1 or cl. 22- Cross-linked polyetdylene 2XI1 acc. to VDE 0276-604- Color coded to DIN VDE 0293(HD 308)- PVC filler4- Galvanized round steel / aluminum wire armour5- PVC outer jacket DMV5 to HD 603.1Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 3500 volts- Minimum bending radius: 15 x Ø- Flexing temperature: -5º C to +70º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +250º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²CONDUCTORTYPETHICKNESS OF INSULATION MMTHICKNESS OF SHEATH MMNOMINALOVERALL DIAMETER MMCABLE WEIGHT KG / KM41x25rm0.91.816.650321x35rm0.91.817.761211x50rm11.819.57832/01x70rm1.11.821.510143/01x95rm1.11.823.512804/01x120rm1.21.826.01575300mcm1x150rm1.41.827.51872350mcm1x185rm1.61.830.02294500mcm1x240rm1.71.933.02923750mcm1x300rm1.82.136.03509-1x400rm2240.54534-1x500rm2.22.345.05691-1x630rm2.42.549.57267-1x800rm0.71.856.59271162x1.5re/rm0.71.813.6325142x2.5re/rm0.71.814.5379122x4re/rm0.71.815.7448102x6re/rm0.71.816.853082x10rm0.71.819.478362x16rm0.71.822.098242x25rm0.91.825.5144722x35rm0.91.828.0176512x50rm11.930.521062/02x70rm1.1235.027653/02x95rm1.12..239.537464/02x120rm1.22.343.54465300mcm2x150rm1.42.547.55303350mcm2x185rm1.62.654.06890500mcm2x240rm1.72.859.58463750mcm2x300rm1.83.165.010151163x1.5re/rm0.71.814.1351143x2.5re/rm0.71.815.1415123x4re/rm0.71.816.3503103x6re/rm0.71.817.560383x10rm0.71.820.590363x16rm0.71.823.0116143x25rm0.91.827.0170923x35rm0.91.829.5212713x50sm11.931.524242/03x70sm1.11.936.534383/03x95sm1.1240.043434/03x120sm1.22.243.55172300mcm3x150sm1.42.349.56675350mcm3x185sm1.62.554.07977500mcm3x240sm1.72.660.09995750mcm3x300sm1.82.865.011990164x1.5re/rm0.71.814.9395144x2.5re/rm0.71.816.0470124x4re/rm0.71.817.4575104x6re/rm0.71.819.579884x10rm0.71.822.0105864x16rm0.71.825.5151844x25rm0.91.829.0205524x35rm0.91.932.0258514x50sm1235.530402/04x70sm1.12.141.043053/04x95sm1.12.245.054764/04x120sm1.22.451.57064300mcm4x150sm1.42.557.58536350mcm4x185sm1.62.761.510189500mcm4x240sm1.72.868.012772750mcm4x300sm1.8373.515380165x1.5re/rm0.71.815.8441145x2.5re/rm0.71.817.0535125x4re/rm0.71.819.3768105x6re/rm0.71.821.092185x10rm0.71.823.5123565x16rm0.71.827.0176545x25rm0.91.831.5242325x35rm0.91.934.5305715x50rm1.12.240.04099


Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

P30 RFOU-HCF / TFOU-HCF 6/10(12) KV NEK606 Cable
P30 RFOU-HCF / TFOU-HCF 6/10(12) KV NEK606 Cable P30 RFOU-HCF / TFOU-HCF 6/10(12) kV Fire resistant NEK606 MV cableApplications :These cables are fire resistant,Website:, flame retardant, low smok...
2YSLGCGOEU Signal & Control Cable VDE 0250 Part 812
2YSLGCGOEU Signal & Control Cable VDE 0250 Part 812 2YSLGCGOEU Signal & Control Cable VDE 0250 Part 812ApplicationsThese control,Website:, signalling and bus cables are used for electric and electron...
XLPE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Multicore)
XLPE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Multicore) XLPE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multicore)RE-2X(St)H 90°C / 500VSTANDARDS Basic design to EN 5028...
Harmonized Code Industrial Cables H00V-D
Harmonized Code Industrial Cables H00V-D Harmonized Code Industrial Cables H00V-DApplication and DescriptionThese high flexible eartd conductors are used for eartding of portable equipmen...
Type 455 3.3 To 33KV To AS/NZS 2802
Type 455 3.3 To 33KV To AS/NZS 2802 Type 455 3.3 to 33KV to AS/NZS 2802ApplicationsThese cables are designed with reduced insulation and sheath thickness,Website:, no cradle, 2 earth ...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes