N2XRY

German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts and in the open where better mechanical protection is required, or for higher tensile stress during installation and operation. Suitable for comparatively high ambient temperature due to high maximum permissible conductor temperature.Standard and ApprovalIEC 60502-1, VDE 0276-604, BS5467Cable Construction1- Solid or stranded, plain copper conductor- to DIN VDE 0295 cl. 1 or cl. 2, BS 6360 cl. 1 or cl. 2 and IEC 60228 cl. 1 or cl. 22- Cross-linked polyetdylene 2XI1 acc. to VDE 0276-604- Color coded to DIN VDE 0293(HD 308)- PVC filler4- Galvanized round steel / aluminum wire armour5- PVC outer jacket DMV5 to HD 603.1Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 3500 volts- Minimum bending radius: 15 x Ø- Flexing temperature: -5º C to +70º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +250º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²CONDUCTORTYPETHICKNESS OF INSULATION MMTHICKNESS OF SHEATH MMNOMINALOVERALL DIAMETER MMCABLE WEIGHT KG / KM41x25rm0.91.816.650321x35rm0.91.817.761211x50rm11.819.57832/01x70rm1.11.821.510143/01x95rm1.11.823.512804/01x120rm1.21.826.01575300mcm1x150rm1.41.827.51872350mcm1x185rm1.61.830.02294500mcm1x240rm1.71.933.02923750mcm1x300rm1.82.136.03509-1x400rm2240.54534-1x500rm2.22.345.05691-1x630rm2.42.549.57267-1x800rm0.71.856.59271162x1.5re/rm0.71.813.6325142x2.5re/rm0.71.814.5379122x4re/rm0.71.815.7448102x6re/rm0.71.816.853082x10rm0.71.819.478362x16rm0.71.822.098242x25rm0.91.825.5144722x35rm0.91.828.0176512x50rm11.930.521062/02x70rm1.1235.027653/02x95rm1.12..239.537464/02x120rm1.22.343.54465300mcm2x150rm1.42.547.55303350mcm2x185rm1.62.654.06890500mcm2x240rm1.72.859.58463750mcm2x300rm1.83.165.010151163x1.5re/rm0.71.814.1351143x2.5re/rm0.71.815.1415123x4re/rm0.71.816.3503103x6re/rm0.71.817.560383x10rm0.71.820.590363x16rm0.71.823.0116143x25rm0.91.827.0170923x35rm0.91.829.5212713x50sm11.931.524242/03x70sm1.11.936.534383/03x95sm1.1240.043434/03x120sm1.22.243.55172300mcm3x150sm1.42.349.56675350mcm3x185sm1.62.554.07977500mcm3x240sm1.72.660.09995750mcm3x300sm1.82.865.011990164x1.5re/rm0.71.814.9395144x2.5re/rm0.71.816.0470124x4re/rm0.71.817.4575104x6re/rm0.71.819.579884x10rm0.71.822.0105864x16rm0.71.825.5151844x25rm0.91.829.0205524x35rm0.91.932.0258514x50sm1235.530402/04x70sm1.12.141.043053/04x95sm1.12.245.054764/04x120sm1.22.451.57064300mcm4x150sm1.42.557.58536350mcm4x185sm1.62.761.510189500mcm4x240sm1.72.868.012772750mcm4x300sm1.8373.515380165x1.5re/rm0.71.815.8441145x2.5re/rm0.71.817.0535125x4re/rm0.71.819.3768105x6re/rm0.71.821.092185x10rm0.71.823.5123565x16rm0.71.827.0176545x25rm0.91.831.5242325x35rm0.91.934.5305715x50rm1.12.240.04099
Other supplier products
|
|
|
Industrial Cables H05V-KApplication and DescriptionThese insulated wires are determined for installation to tde inside of apparatus as well as for ... |
|
|
|
XLPE Insulated,Website:, LSZH sheathed, CWB screened Instrumentation cables (Multipair)RE-2X(c)H 90°c / 300VSTANDARDSBasic design to EN 50288-7APPL... |
|
|
|
300/500V XLPE Insulated,Website:, PVC Sheathed Power Cables (Single Core)Application:The cables are mainly used in power stations, mass transit und... |
|
|
|
150/250V Mica Tape + XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair/Multitriple... |
|
|
|
(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts... |
供应产品
Same products