.

300 500V PVC Insulated, PVC Sheathed Power Cables (2-5 Cores)

300/500V PVC Insulated,Website:, PVC Sheathed Power Cables (2-5 Cores)05VV-K (CU/PVC/PVC 300/500V Class 5)BS Code: 3182Y/3183Y/3184Y/3185YHAR Code: H05VV-FApplication:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design to BS EN formerly BS 6500)Fire Performance:Flame Retardance (Single Vertical Wire Test) EN 60332-1-2Voltage Rating:300/500VConductorFlexible copper wire according to EN 60228 class 5.InsulationPVC type TI 2 according to EN 50363-3.FillingFor circular cable having two cores, the space between the cores shall be filled either by separate fillers or by the sheath filling the interstices. For circular cables with three, four or five cores, a centre filler may be used.Outer SheathPVC type TM 2 according to EN 50363-4-1. A tape may be applied around the core assembly before application of the sheath.Sheath OptionUV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.Colour CodeInsulation ColourCables and cords with a green-and-yellow coresNo. of coresColour of coresbProtectiveLive3 CoresYellow/GreenBlueBrown4 CoresYellow/Green-BrownBlackGrey4 CoresaYellow/GreenBlueBrownBlack5 CoresYellow/GreenBlueBrownBlackGreya For certain applications only.b In this table an uninsulated concentric conductor, such as a metallic sheath, armour or screen wire, is not regarded as a core. A concentric conductor is identified by its position and, therefore, need not be identified by colour.Cables and cords without a green-and-yellow coresNo. of coresColour of coresb2 CoresBlueBrown3 Cores-BrownBlackGrey3 CoresaBlueBrownBlack4 CoresBlueBrownBlackGrey5 CoresBlueBrownBlackGreyBlacka For certain applications only.b In this table an uninsulated concentric conductor, such as a metallic sheath, armour or screen wire, is not regarded as a core. A concentric conductor is identified by its position and, therefore, need not be identified by colour.Sheath Colour: Black (other colors upon request)Physical And Thermal PropertiesMaximum temperature range during operation (PVC)60°CMaximum short circuit temperature (5 Seconds)150°CMinimum bending radiusUp to 12mm²: 3 x overall diameterAbove 12mm²: 4 x overall diameterConstruction ParametersNo. of Core X Cross SectionNominal Insulation ThicknessNominal Sheath ThicknessMaximum Overall DiameterApprox. WeightNoxmm2mmmmmmkg/km2x0.750.60.87.2572x1.00.60.87.5652x1.50.70.88.6872x2.50.81.010.61342x40.81.112.11743x0.750.60.87.6683x1.00.60.88.0793x1.50.70.99.41113x2.50.81.111.41693x40.81.213.12334x0.750.60.88.3844x1.00.60.99.01014x1.50.71.010.51424x2.50.81.112.52114x40.81.214.32925x0.750.60.99.31065x1.00.60.99.81235x1.50.71.111.61765x2.50.81.213.92625x40.81.416.1369Electrical PropertiesCurrent-Carrying Capacities (Amp) according to BS7671:2008 table 4F3AConductor cross-sectional areaSingle-phase a.c.Three-phase a.c.mm2AA0.5330.75661.010101.516162.5252043225Voltage Drop (Per Amp Per Meter) according to BS7671:2008 table 4F3BConductor cross-sectional aread.c. or single-phase a.c.Three-phase a.c.mm2mV/A/mmV/A/m0.593800.7562541.046401.532272.5191641210


Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

RHH/RHW-2, 600V
RHH/RHW-2, 600V UL Industrial Cables RHH/RHW-2,Website:, 600V, Power Cable, CT RatedApplication and DescriptionType RHH or RHW-2 or USE-2 conductors are for use in...
THHN/THWN, 600V, Type TC Control Cable
THHN/THWN, 600V, Type TC Control Cable UL Industrial Cables THHN/THWN,Website:, 600V, Type TC control Cable Application and DescriptionType TC Control Cable is for use in industrial powe...
600 1000V PVC Insulated, Non-sheathed Power Cables (Single Core)
600 1000V PVC Insulated, Non-sheathed Power Cables (Single Core) 600/1000V PVC Insulated,Website:, Non-sheathed Power Cables (Single Core) (CU/PVC 600/1000V Class 2)Application:The cables are mainly used in power...
(FA-)SPYC, SPYCB (FA-)SPYCY, SPYCBY
(FA-)SPYC, SPYCB (FA-)SPYCY, SPYCBY 0.6/1KV (FA-)SPYC,Website:, SPYCB (FA-)SPYCY, SPYCBYStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorSTi...
Harmonized Code Industrial Cables H05GG-F
Harmonized Code Industrial Cables H05GG-F Harmonized Code Industrial Cables H05GG-FApplication and DescriptionFor general use in domestic premises,Website:, kitchens and offices and for sup...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes