300/500V Mica+XLPE Insulated, LSZH Sheathed Power Cables (Single Core)

300/500V Mica+XLPE Insulated,Website:, LSZH Sheathed fire resistant Power Cables (Single Core)(CU/MGT+XLPE/LSZH 300/500V Class 2)Application:These cables are designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, lifts, escalators, and high-rise buildings.STANDARDS:Basic design to IEC 60502-1FIRE PERFORMANCECircuit IntegrityIEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)System circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING300/500 VCABLE CONSTRUCTION 1 Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.2 Insulation: Mica glass tape covered by extruded cross-linked XLPE compound3 Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -30°C – +90°CTemperature range during installation (mobile state): -20°C – +50°CMinimum bending radius: 8 x Overall DiameterElectrical PROPERTIESDielectric test:2000 V r.m.s. x 5' (core/core)Insulation resistance1000 MΩ x km (at 20°C)Short circuit temperature250°CCONSTRUCTION PARAMETERSConductorNominal Cross Section AreaNo./ Nominal Diameter of trandsNominalInsulationThicknessNominalSheathThicknessWithout Earth ConductorNominalOverallDiameterApprox.Weightmm2No./mmmmmmmmkg/km1.57/0.530.50.54.4292.57/0.670.50.54.94047/0.850.50.55.555Electrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)ConductorcrosssectionareaReference Method 4(enclosed in conduitin thermally insulatingwall etc)ReferenceMethod 3(enclosed inconduit on a wall or in trunkingetc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal orvertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables,single-phasea.c. or d.c.3 or 4cables,3-phasea.c.2cables,single-3 or 4cables,3-phasea.c.2 cables,single-phasea.c. or d.c. flatand touching3 or 4cables,3-phasea.c. flatandtouchingor trefoil2 cables,single-phase a.c.or d.c. or flat and touching3 or 4cables,3-phasea.c. flatand touchingor trefoil2 cables,single-phasea.c. or d.c. or 3 cables threephase2 cables,single-phasea.c. or d.c. or3 cables threephase3 cables,trefoil3-phasephase a.c.phase a.c.a.c. ord.cmm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)NominalCrossSectionArea2 cablesd.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3and 4 (enclosedin conduit etc,in or on a wall)Ref. Methods 1and 11 (clippeddirect or on traystouching)Ref. Methods 3and 4 (enclosedin conduit etc,in or on a wall)Ref. Methods 1,Ref. Methods 1 and1111 and 12(in trefoil)(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1..
Other supplier products
|
|
(N)SSHOEU 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812 |
(N)SSHOEU 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812ApplicationsThese cables are used for connection of mobileequipment and machines under... |
|
|
Fire Resistant FTP Cat3 Data Cables |
Fire resistant FTP Cat3 Data Cables FR-CAT3FTP 4P22FRApplication:The cables are desgined for structure wiring,Website:, compatible with all known c... |
|
|
Type 241 1.1 To 11KV To AS/NZS 1802 |
Type 241 1.1 to 11KV to AS/NZS 1802ApplicationsThese cables are designed for various uses,Website:, including main feeder cable for continuous mine... |
|
|
N2XRY |
German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts ... |
|
|
Flame Retardant CAT6 Armoured Data Cables LSZH Sheath |
Flame Retardant CAT6 Armoured Data Cables Application:Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol,Website:, suit... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |