HEPA Filter Element Quality Control Test SystemEN 1822-3 HEPA and ULPA filter testing System
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The HEPA Filter Element Quality Control Test System is designed for quality control of small HEPA filter elements in production. It complies with EN 1822-4 and ISO 29463-4. Appendix E (“Efficiency and leakage test for particle size 0.3–0.5 µm”). The system is suitable for filter elements that cannot be scanned due to geometric design, ensuring overall filter efficiency is sufficient for production QC.
Application
(1) Small HEPA Filter Element Efficiency Testing: Verification of overall efficiency for small HEPA elements.
(2) HEPA Filter Grade Confirmation: Determine HEPA classification according to standards.
(3) Integrated Production Control: Can be integrated into the production line for real-time quality assurance.
Standards
The system supports and complies with:
(1) GB/T 13554-2020 – High-efficiency air filters.
(2) GB/T 6165-2021 – HEPA filter performance: efficiency and resistance.
(3) EN 1822-3 – HEPA and ULPA filter testing methods.
(4) EN 1822-4 – Efficiency and leakage test for HEPA filters (0.3–0.5 µm).
(5) ISO 29463-4 – HEPA/ULPA filter performance standard.
(6) ISO 29463-3 – HEPA/ULPA filter design, performance, and acceptance testing.
Parameters
| Parameter | Unit | Value |
|---|---|---|
| Test Flow Rate | m³/h | 25 … 130 |
| Test Cycle | s | 30 |
| Differential Pressure Range | Pa | 0 … 3000 (±1% final value) |
| Test Sample Dimensions | mm | Max 300 × 300 × 300 |
| Power Supply | – | 3 × 400 VAC, 50/60 Hz, 16 A |
| Operating Gas/Air | – | Custom (DEHS, paraffin oil, NaCl, etc.) |
| Particle Measurement | – | Particle counter (4 or 8 channels) with vacuum pump |
| Other Sensors | – | Temperature, relative humidity, barometric pressure |
| System Dimensions (W × H × D) | mm | 2000 × 1500 × 1000 |
| Weight | kg | approx. 600 |
Features
Configurable Target Efficiency and Pressure Drop: Freely set for each filter element according to production requirements.
Custom Filter Adapters: Adaptable to different small HEPA elements, quick change (~5 minutes).
Compact Design: Small footprint suitable for production environments.
High Automation: Minimal operator intervention, fast test completion.
24/7 Production Support: Suitable for continuous manufacturing operations.
Fast Test Cycle: 30 seconds per filter element ensures high throughput.
Safety Features: Complete protection for production environments.
Traceable Data Management: Test results are recorded and reports generated for quality tracking.
Accessories
| Accessory | Quantity |
|---|---|
| Aerosol Generator | 1 |
| Particle Counter (4 or 8 channels) | 1 |
| Self-Regulating Dilution System | 1 |
| Test Filter Adapter | Customized per filter element |
| Temperature & Humidity Sensor | 1 |
Test Principle
Overall Efficiency Testing:
DEHS aerosol is generated upstream; particle concentrations are measured upstream and downstream.
Upstream concentration is measured with an optical particle counter and adjusted via the dilution system.
Downstream concentration is measured similarly; overall efficiency is calculated and compared to nominal target.
Efficiency Comparison:
Overall measured efficiency is compared with target efficiency to quickly classify “pass” or “fail.”
Differential Pressure Measurement:
Measures pressure drop across the filter element, generating pressure curves and dust loading capacity data to ensure stable performance at different flow rates.
Operation Instructions
System Startup:
- Check connections (air, power, aerosol generator).
- Set target efficiency, pressure drop, and other test parameters.
- Start the test program.
Testing Process:
- Install small HEPA filter elements into custom adapters.
- System automatically conducts efficiency and differential pressure tests.
Data Recording and Reporting:
- Upon test completion, results are stored in the database.
- Generate detailed reports supporting quality traceability.
Experimental Procedure
Preparation:
- Configure test parameters (target efficiency, flow rate).
- Install filter elements in adapters.
- Verify aerosol generator and particle counters are operational.
Testing:
- System automatically measures differential pressure, efficiency, and dust loading.
- Upstream and downstream particle concentrations are recorded.
Result Processing:
- System provides “pass/fail” results and generates detailed reports.
Maintenance Information
Regularly check aerosol generators and particle counters.
Calibrate sensors periodically.
Keep the system clean to maintain accurate measurements.
Send product request
Other supplier products
| Spray Rating Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards: ISO 4920. BS EN 24920. BS 3702. GB/T 4745. AATCC 22. M&S P23. NEXT 23 Appl... | |
| Four-point Bending Tester | Standard YY/T 0591 (China): Standard for static four-point bending tests of lockable intramedullary nails. ASTM F1264 (International): Specificat... | |
| Commercial dry cleaner | The Commercial Dry Cleaner is a high-performance rotary and hydrocarbon-based dry cleaning machine designed for professional textile care and indus... | |
| Nasal Oxygen Cannula Tester | This device is used to test various performance characteristics of nasal cannulas, such as airflow resistance and resistance to kinking. It is also... | |
| Compression Fatigue Tester | Standard YY/T 0959-2014 (China): Specifies compression fatigue testing protocols for intervertebral fusion devices, including load ratios, frequen... |
Same products
| SUGA SX75 super xenon weather meter supplier | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications SUGA SX75 7.5kW Super Xenon... | |
| UV & Carbon Arc Light Exposure Tester | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Carbon Arc Aging Chambe... | |
| Acid corrosion resistance cabinet for toilets | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Toilet seat hydrochloric ac... | |
| Automated Filter Porosity Testing System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Determining pore size di... | |
| Spray Aerosol Ignition Distance Tester | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Spray Aerosol Ignition Dist... |