.

Manikin Coughing System

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Application

HVAC education and research, including indoor air quality evaluation, human breathing exposure assessment in confined spaces, and cross-infection risk analysis of airborne diseases;

Medical and public health research, including studies on respiratory exposure, pollutant dispersion, and effectiveness of protective measures;

Occupational health assessment, such as evaluation of dust, PM2.5. and gaseous pollutant exposure in workshops and factories;

Breathing exposure assessment in aerospace cabins and confined environments, including civil and military aircraft, helicopters, space stations, re-entry capsules, submarines, and deep-sea systems;

Breathing exposure assessment inside vehicles and transportation systems, including buses, passenger cars, new energy vehicles, high-speed trains, subways, ships, and submarines;

Evaluation of breathing exposure and comfort of wearable masks, including space suits, pilot oxygen masks, aircraft passenger oxygen masks, and chemical protective mask systems.

Standards

GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)

GB/T 18883-2022 — Indoor Air Quality Standard

ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort

ASTM F1291-2020 — Test Methods Related to Breathing and Exposure Measurement

Product Specifications

ComponentTechnical Parameters
Breathing Function Sinusoidal breathing profile; breathing frequency 10 breaths/min (one cycle 6.0 s: exhalation 2.0 s, inhalation 2.0 s, pause 2.0 s); customizable on request
Exhalation Volume Adjustable: 7 L/min, 15 L/min, 23 L/min; exhalation positive pressure 10–80 kPa (0.1–0.8 bar); inhalation negative pressure approx. −0.4 bar
Breathing Mode Switchable nasal breathing or oral breathing (when used with a thermal manikin)
Exhaled Airflow Equipped with heating module; airflow temperature adjustable from 34 to 36 °C
Sampling Branch Main breathing line includes a sampling port for aerosol or pollutant sampling
Electrical Control System Integrated control cabinet with pressure gauges and flow display; power supply AC 220 V / 50 Hz; total power ≤ 350 W; exhaled air heating module power ≤ 1000 W
Operating Environment Temperature 10–40 °C; humidity 15–95%
Others Can be used with a thermal manikin or independently with a manikin head; platform with lockable caster wheels; over-pressure and short-circuit protection; total weight approx. 45 kg

Accessories

Accessory / ConsumableSpecification
Breathing Control Cabinet Includes PID control, pressure gauges, and flow display modules
Heating Module Exhaled air heating module with adjustable temperature from 34 to 36 °C
Main Breathing Line Equipped with sampling branch for aerosol or pollutant sampling devices
Quick-Connect Cables For connection to thermal manikin or head model, easy installation and removal
Customizable Modules Nasal or oral breathing interfaces; child or infant manikin compatible modules

Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Computer-controlled Helmet Impact Tester
Computer-controlled Helmet Impact Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com A computer-controlled helmet impact tester is an instrument used to test the impact resista...
IEC 60695-11-5 Automotive Wire Flame Test Equipment Supplier Factory Direct
IEC 60695-11-5 Automotive Wire Flame Test Equipment Supplier Factory Direct Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features Needle Burner Design: Φ0.5mm inner hole, 45° tilt angle for...
Automotive Seating Ergonomics Entry Exit Testing Equipment SAE & ISO Standard
Automotive Seating Ergonomics Entry Exit Testing Equipment SAE & ISO Standard Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The True Body Weight Ingress/Egress Tester is a specialized machine designed ...
Air Jet Erosion Tester
Air Jet Erosion Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Air Jet Erosion Tester is a controlled gas-driven erosion testing system designed to ev...
Medical Laboratory Balloon Catheter Testing Equipment Manufacturer
Medical Laboratory Balloon Catheter Testing Equipment Manufacturer Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Balloon Inflation Diameter Tester is a precision device widely u...
All supplier products

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Seller: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...