Application
HVAC education and research, including indoor air quality evaluation, human breathing exposure assessment in confined spaces, and cross-infection risk analysis of airborne diseases;
Medical and public health research, including studies on respiratory exposure, pollutant dispersion, and effectiveness of protective measures;
Occupational health assessment, such as evaluation of dust, PM2.5. and gaseous pollutant exposure in workshops and factories;
Breathing exposure assessment in aerospace cabins and confined environments, including civil and military aircraft, helicopters, space stations, re-entry capsules, submarines, and deep-sea systems;
Breathing exposure assessment inside vehicles and transportation systems, including buses, passenger cars, new energy vehicles, high-speed trains, subways, ships, and submarines;
Evaluation of breathing exposure and comfort of wearable masks, including space suits, pilot oxygen masks, aircraft passenger oxygen masks, and chemical protective mask systems.
Standards
GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)
GB/T 18883-2022 — Indoor Air Quality Standard
ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort
ASTM F1291-2020 — Test Methods Related to Breathing and Exposure Measurement
Product Specifications
| Component | Technical Parameters |
|---|---|
| Breathing Function | Sinusoidal breathing profile; breathing frequency 10 breaths/min (one cycle 6.0 s: exhalation 2.0 s, inhalation 2.0 s, pause 2.0 s); customizable on request |
| Exhalation Volume | Adjustable: 7 L/min, 15 L/min, 23 L/min; exhalation positive pressure 10–80 kPa (0.1–0.8 bar); inhalation negative pressure approx. −0.4 bar |
| Breathing Mode | Switchable nasal breathing or oral breathing (when used with a thermal manikin) |
| Exhaled Airflow | Equipped with heating module; airflow temperature adjustable from 34 to 36 °C |
| Sampling Branch | Main breathing line includes a sampling port for aerosol or pollutant sampling |
| Electrical Control System | Integrated control cabinet with pressure gauges and flow display; power supply AC 220 V / 50 Hz; total power ≤ 350 W; exhaled air heating module power ≤ 1000 W |
| Operating Environment | Temperature 10–40 °C; humidity 15–95% |
| Others | Can be used with a thermal manikin or independently with a manikin head; platform with lockable caster wheels; over-pressure and short-circuit protection; total weight approx. 45 kg |
Accessories
| Accessory / Consumable | Specification |
|---|---|
| Breathing Control Cabinet | Includes PID control, pressure gauges, and flow display modules |
| Heating Module | Exhaled air heating module with adjustable temperature from 34 to 36 °C |
| Main Breathing Line | Equipped with sampling branch for aerosol or pollutant sampling devices |
| Quick-Connect Cables | For connection to thermal manikin or head model, easy installation and removal |
| Customizable Modules | Nasal or oral breathing interfaces; child or infant manikin compatible modules |
Send product request
Other supplier products
| Carpet Abrasion Resistance Tester | Standard ASTM D4157(Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method)) ISO 12947-2(Textiles - Deter... | |
| Sliding bearing PV friction testing machine | The testing machine can monitor the changes in friction force and the wear condition of the sample surface in real time during the test, and also p... | |
| Lowest Ignition Energy (MIE) Dust Cloud Analyzer | Description: Dust Cloud Minimum Ignition Energy Tester disperses a certain mass of dust specimen to be tested into the Hartmann tube device throug... | |
| Large diameter blasting test machine | Standard ASTM D1599: Compliant for short-time hydraulic failure testing of thermoplastic pipes under linear pressure ramp. ISO 1167: Configurable... | |
| Flat-Panel Air-Cooled Xenon Lamp Weathering Test Chamber | Applications Flat-Panel Air-Cooled Xenon Lamp Weathering Test Chamber employs xenon arc lamps capable of simulating the full solar spectrum to rep... |
Same products
| Tabletop Xenon Arc Weathering Tester (SunMaster) | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Water-Cooled Xenon Lamp Weat... | |
| Blow-By Test Rig | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test system for the characterisa... | |
| Air filter System(ISO 16890/EN 779) | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Filter test system for general a... | |
| Oil Thread Leak Test System | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test System for oil thread leak ... | |
| Manual HEPA/ULPA Filter Scanning Test System | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Manual HEPA/ULPA Filter Scan... |