Adjustable nasal oxygen catheter tester instrument

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

The nasal oxygen tube tester is mainly used to test key parameters of nasal oxygen tubes, such as oxygen content, flow rate, and pressure, as well as to evaluate their physical properties like pressure - resistance, crush - resistance, and air permeability. This tester plays an important role in various aspects, including the production, quality control, and pre - use inspection of nasal oxygen tubes, ensuring that nasal oxygen tubes can provide patients with a stable and effective oxygen supply. Specifically, its main uses are as follows:

- Production Quality Control: During the production of nasal oxygen tubes, manufacturers can use this tester to conduct sampling inspections on finished products, ensuring that each batch of nasal oxygen tubes complies with relevant standards and regulations. - Pre - use Inspection: Before using nasal oxygen tubes, medical institutions can use this tester to conduct quality inspections to ensure that the performance of nasal oxygen tubes is stable, safe, and reliable. - Research, Development and Improvement: The nasal oxygen tube tester can also be used in the research, development and improvement process of nasal oxygen tubes, helping R & D personnel understand the performance characteristics and deficiencies of nasal oxygen tubes, so as to make targeted improvements and optimizations.

Standards

YY/T 1543 - 2017:Nasal Oxygen Cannula

GB/T 1962.1-2005:Conical fittings with a 6%(Luer) taper for syringes, needles and certain other medical equipment -- Part 1: General requirement

Technical Parameters

ParameterSpecification
Test Pressure Range Usually covers 0 - 600kPa or higher, to meet testing requirements of nasal oxygen tubes with different specifications and materials
Test Flow Range Simulates normal oxygen supply flow (e.g., not less than 15L/min), ensuring air permeability of nasal oxygen tubes in actual use
Accuracy High level of accuracy; e.g., pressure accuracy reaches ±1% or higher, ensuring test result accuracy and reliability
Data Collection and Display Equipped with data collection card and display screen, which collect and display real-time test data (pressure, flow rate, time, etc.) for easy observation and recording
Clamping Device Fixes nasal oxygen tubes to keep their position stable (no displacement/shaking during testing); adaptable to nasal oxygen tubes of different specifications and shapes
Operation Interface Simple and clear for easy operation; some testers are equipped with touch-screen control and menu-style functions to improve operational convenience

Accessoriess

1 main unit;

1 set of testing software;

1 instruction manual;

1 certificate of conformity;

1 warranty card;

1 delivery receipt;

1 nameplate;

1 power cord;

1 set of wrenches;

Several brochures;

1 x 1/8 barbed connector;

1 x 1/8 Luer connector (male).


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Diesel Water Ash Sulfur Test Equipment
Diesel Water Ash Sulfur Test Equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications 1. In diesel quality control, homogenization of samples provides representati...
Rapid screening Calorimeter
Rapid screening Calorimeter Whats/App: +86 156 1874 6768 Web: standard-groups.com The rapid - screening calorimeter is a professional calorimetric instrument for the quick a...
Airflow conditioning environmental chamber manufacturer
Airflow conditioning environmental chamber manufacturer Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards Internal compliance with laboratory safety, electrical, and environmental simula...
Custom fully automatic scratch hardness tester system
Custom fully automatic scratch hardness tester system Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Primary applications: Evaluation of scratch resistance on insulated single-la...
Automotive Interior Materials Tactile Perception Quality Testing Procedure System
Automotive Interior Materials Tactile Perception Quality Testing Procedure System Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Automotive seat surfaces: leather, fabric, synthetic leather, and composit...
All supplier products

Same products

Laser Cutting Machines
Laser Cutting Machines Seller: Chanxan (Changshu) Laser Technology Co., Ltd. Laser Cutting Machines PrecisionLaser Cutting Systemsfor Film, Glass & Industrial Materials ...
Precision Laser Micromachining Machine
Precision Laser Micromachining Machine Seller: Chanxan (Changshu) Laser Technology Co., Ltd. Precision Laser Micromachining Machine| Ultrafast Laser Micromachining Systems Chanxan provides ...
Ultrafast Laser Systems
Ultrafast Laser Systems Seller: Chanxan (Changshu) Laser Technology Co., Ltd. Ultrafast Laser Systems Femtosecond Laser System Ultra-precision femtosecond laser systemfor hi...
Industrial Laser Equipment Manufacturer
Industrial Laser Equipment Manufacturer Seller: Chanxan (Changshu) Laser Technology Co., Ltd. Industrial Laser Equipment Manufacturer for Precision Cutting, Marking & Micromachining Chan...
Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 Seller: 868983 Common Rail Injector Valve F00R J02 012 David Chen