Adhesion Tester for quality control

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

- Specific standards for different test objects, such as the adhesion test standards for medical gels, cosmetics and skin

- care products, food packaging materials, etc.

- General standards in the adhesive industry, such as GB/T 2792 Test Method for 180°Peeling Strength of Pressure

- Sensitive Adhesive Tapes, ASTM D3330 Standard Test Method for Peel Adhesion of Pressure - Sensitive Tape, etc. These standards specify in detail the test methods for the adhesion tester, specimen preparation, test conditions, etc., providing a unified standard for the use of the tester.

Features

1. 7-inch touchscreen control, stylish human-machine interface

2. Lead screw drive system, greatly improving the accuracy of transmission displacement and enabling stepless speed regulation.

3. Allows for parameter setting, printing, clearing, calibration, and other operations.

4. Calibration interface password protected to prevent errors in calibration force values due to accidental operation.

5. Features power-off memory, overload protection, and line position protection.

6. The instrument has applied for a patent for its sensor protection device function, patent number: ZL.8

7. Equipped with a standard USB interface and a printer interface for easy connection to a computer.

8. The instrument can complete tests independently, and the mini printer automatically prints the test results.

Technical Parameters

Technical ParameterSpecification
Measurement Range Usually covering 0 - 30000mN or wider (adapts to different materials). Some devices have a smaller range (e.g., 0.01N - 100N), suitable for materials with relatively low adhesion.
Measurement Accuracy Generally grade 0.5 or higher; ensures the accuracy of test results.
Stroke Usually 650mm or longer; meets requirements of different specimen sizes and test methods.
Pressing Roller Mass Usually 2000g±50g; applies pressure to the specimen to ensure tight adhesion between the specimen and the test plate.
Test Speed Adjustable range: generally 1 - 500mm/min (stepless speed regulation) to simulate different peeling speeds; some devices have a wider speed-adjustment range.
External Dimensions Usually about 880mm (length) × 320mm (width) × 400mm (height); facilitates placement and movement (dimensions vary by brand/model).
Power Supply Usually AC 220V 50Hz (ensures normal operation of the tester); some devices support other voltages and frequencies.

Accessoriess

Standard Configuration: Main unit, standard fixtures, mini printer

Optional Accessories: Professional software, communication cable, test plate, standard pressure roller, sampling knife, custom-made non-standard fixtures

Note: This machine can operate independently. If connection to a computer is required, the computer must be provided by the user. The mini printer is thermal.

Test Procedures

1. Equipment Preparation

Connect to AC 220V 50Hz power supply. Use a standard adhesion sample calibration device conforming to GB/T 2792 (ensuring measurement accuracy of 0.5 grade or higher). Confirm that the pressure roller (2000g±50g), clamps, and other components are in normal condition.

2. Sample Preparation

According to the test object (e.g., medical adhesive removal, food packaging materials),

cut the sample according to the corresponding standard (e.g., ASTM D3330) (e.g., for 180-degree peel tests, the sample size must match). Clean the sample and test plate surfaces (remove impurities to avoid affecting adhesion).

3. Parameter Settings

Select the compliant standard (e.g., GB/T 2792) through the instrument interface, set the measurement range (e.g., 0-30000mN), and test speed (1-500mm/min, select as needed). 4. Sample Adhesion and Clamping

Affix the sample to the test plate and roll it back and forth with the pressure roller a specified number of times (e.g., the number of rolls required by the standard) to ensure a tight fit between the sample and the test plate.

Then, fix the test plate/sample to the instrument fixture, aligning it with the force direction of the peel/adhesion test (e.g., the fixture angle for a 180-degree peel).

5. Start the Test

After confirming that the clamping and parameters are correct, start the test program. The instrument will automatically complete the adhesion force test at the set speed and record the force value data in real time.

6. Result Processing

After the test, export the data and determine whether the adhesion force meets the requirements by referring to the corresponding standard (e.g., ASTM D3330). If multiple tests are required, repeat the sample clamping and testing steps.

7. Post-processing

Remove the sample, clean the fixture, pressure roller, and test plate, and turn off the equipment power.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Filter Performance and Durability Testing System
Filter Performance and Durability Testing System Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Filter element dynamic cycling test bench is mainly used to test the chemical...
Professional flexible packaging film impact tester manufacturer
Professional flexible packaging film impact tester manufacturer Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Pendulum Impact Testing Machine for Plastics and Composite Materials.Pendulum...
Surface scratch hardness tester for plastics and metals
Surface scratch hardness tester for plastics and metals Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) JIS K 5600 series – Methods of testing paints (2) ISO 12137-2:1997 &n...
Sliding Bearing Fatigue Testing Machine
Sliding Bearing Fatigue Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com The sliding bearing fatigue testing machine is an important testing device, mainly used to ...
Autocatalytic Decomposition Temperature Tester with Thermal Insulation,autocatalytic decomposition temperature measurement
Autocatalytic Decomposition Temperature Tester with Thermal Insulation,autocatalytic decomposition temperature measurement Whats/App: +86 156 1874 6768 Web: standard-groups.com The Autocatalytic Decomposition Temperature Tester with Thermal Insulation (Adiabatic SADT ...
All supplier products

Same products

HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line Seller: Shandong HUASU Plastic Technology Co.,Ltd. The molds adopt the double flow channel structure and nitriding polishing processed die head. Thi...
PanEVAP & MVR system
PanEVAP & MVR system Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...