Minimum ignition temperature dust cloud tester for ASTM E1491 compliance
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
ASTM E1491-06:Standard Test Method for Thermal Performance of Powder Coatings Using Differential Scanning Calorimetry (DSC)
EN 50281-2-1:Cable Trunking Systems and Cable Ducting Systems for Electrical Installations - Part 2-1: Specific Requirements for Cable Trunking Systems and Cable Ducting Systems with a Non-Metallic Outer Covering - Coated or Uncoated
IEC 61241-2:Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Requirements for Protection Level "e" (Increased Safety)
ISO/IEC 80079-20-2:Explosive Atmospheres - Part 20-2: Material Characteristics for Gas and Dust Atmospheres - Test Methods for Determining the Minimum Ignition Energy (MIE) of Dust Clouds
Features
1) Built-in internationally used testing standards, allowing testing according to standard parameters or custom parameters.
2) Employs fuzzy PID temperature control algorithm for high-precision temperature control.
3) Features a temperature sensor calibration interface for easy calibration and correction.
4) Uses a Gauder-Grunwald furnace with a built-in quartz tube to ensure reliable furnace operation.
5) The furnace cavity material is made of heat-insulating vacuum ceramic fiber, providing excellent thermal insulation.
6) Thermocouples are from international brands, ensuring long-term stable operation.
7) Includes ambient temperature and humidity detection, automatically recording experimental environment information.
8) Remote control ensures personnel safety.
9) Hierarchical user management allows for different levels of account management and control.
10) Plug-and-play USB interface for convenient data management.
11) Professional industrial design, simple and elegant.
12) 7-inch color LCD touchscreen dynamically displays the experimental progress.
Technical Parameters
|
Operating environment |
(5 to 45)°C, <85% RH |
|
Temperature range |
Room temperature to 1000°C |
|
Rising time |
≤20min (room temperature to 500°C) |
|
Temperature control stability |
±5.0°C |
|
Temperature measurement accuracy |
±3.0°C |
|
Temperature measurement precision |
±0.1°C |
|
Powder spray pressure range |
(0 to 100)kPa |
|
Pressure accuracy |
±5% |
|
Storage volume |
500mL |
|
Ambient temperature measurement range |
(-10 to 60)°C |
|
Ambient humidity measurement range |
(5 to 95)% RH |
|
Interface |
USB*2 |
|
Power |
220VAC/50Hz |
|
Power |
2600W |
|
Dimensions |
670mm х 400mm х 590mm |
Accessoriess
1. Core Component: ZR-FCY-8A Dust Cloud Minimum Ignition Temperature Tester - Heating Furnace: Quartz tube (controllable from room temperature to 1000℃), temperature control accuracy ±1% (above 500℃) or ±3% (below 300℃).
2. Dust Spraying System: Compressed air drives dust diffusion, pressure range 0~1 bar.
3. Safety Protection: Wireless remote control operation, audible and visual alarms, mirror-reflective observation window, etc.
Send product request
Other supplier products
| Air Jet Erosion Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Air Jet Erosion Tester is a controlled gas-driven erosion testing system designed to ev... | |
| Car seat component clearance test bench | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Car Seat Component Clearance Test Bench is designed to accurately measure and evaluate ... | |
| Sanitary Napkin Absorption Speed meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main uses: The absorption speed tester is used to measure the absorption speed of sanitary... | |
| Bio-absorbable Internal Fixation Plates and Screws Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Bio-absorbable Internal Fixation Plates and Screws Tester is a specialized mechanical t... | |
| Automatic Nonwoven Liquid Loss Measurement System | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Nonwovens Liquid Loss Tester is a precision instrument designed to evalua... |