Minimum ignition temperature dust cloud tester for ASTM E1491 compliance

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

ASTM E1491-06:Standard Test Method for Thermal Performance of Powder Coatings Using Differential Scanning Calorimetry (DSC)

EN 50281-2-1:Cable Trunking Systems and Cable Ducting Systems for Electrical Installations - Part 2-1: Specific Requirements for Cable Trunking Systems and Cable Ducting Systems with a Non-Metallic Outer Covering - Coated or Uncoated

IEC 61241-2:Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Requirements for Protection Level "e" (Increased Safety)

ISO/IEC 80079-20-2:Explosive Atmospheres - Part 20-2: Material Characteristics for Gas and Dust Atmospheres - Test Methods for Determining the Minimum Ignition Energy (MIE) of Dust Clouds

Features

1) Built-in internationally used testing standards, allowing testing according to standard parameters or custom parameters.

2) Employs fuzzy PID temperature control algorithm for high-precision temperature control.

3) Features a temperature sensor calibration interface for easy calibration and correction.

4) Uses a Gauder-Grunwald furnace with a built-in quartz tube to ensure reliable furnace operation.

5) The furnace cavity material is made of heat-insulating vacuum ceramic fiber, providing excellent thermal insulation.

6) Thermocouples are from international brands, ensuring long-term stable operation.

7) Includes ambient temperature and humidity detection, automatically recording experimental environment information.

8) Remote control ensures personnel safety.

9) Hierarchical user management allows for different levels of account management and control.

10) Plug-and-play USB interface for convenient data management.

11) Professional industrial design, simple and elegant.

12) 7-inch color LCD touchscreen dynamically displays the experimental progress.

Technical Parameters

Operating environment

(5 to 45)°C, <85% RH

Temperature range

Room temperature to 1000°C

Rising time

≤20min (room temperature to 500°C)

Temperature control stability

±5.0°C

Temperature measurement accuracy

±3.0°C

Temperature measurement precision

±0.1°C

Powder spray pressure range

(0 to 100)kPa

Pressure accuracy

±5%

Storage volume

500mL

Ambient temperature measurement range

(-10 to 60)°C

Ambient humidity measurement range

(5 to 95)% RH

Interface

USB*2

Power

220VAC/50Hz

Power

2600W

Dimensions

670mm х 400mm х 590mm

Accessoriess

1. Core Component: ZR-FCY-8A Dust Cloud Minimum Ignition Temperature Tester - Heating Furnace: Quartz tube (controllable from room temperature to 1000℃), temperature control accuracy ±1% (above 500℃) or ±3% (below 300℃).

2. Dust Spraying System: Compressed air drives dust diffusion, pressure range 0~1 bar.

3. Safety Protection: Wireless remote control operation, audible and visual alarms, mirror-reflective observation window, etc.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Electric pencil hardness meter
Electric pencil hardness meter Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: This machine is suitable for all kinds of finished product spray har...
Safety Helmet High Temperature Pre-Treatment Chamber
Safety Helmet High Temperature Pre-Treatment Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com The safety helmet high-temperature pre-treatment chamber is manufactured according to the G...
ASTM E659 Liquid autoignition point tester
ASTM E659 Liquid autoignition point tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Liquid Autoignition Point Tester is a device used to determine the lowest temperature a...
Taber Linear Abraser
Taber Linear Abraser Whats/App: +86 156 1874 6768 Web: standard-groups.com TheTABER Linear Abraser (Abrader) - Model 5750has been engineered to evaluate product&rsquo...
Automotive Cabin Air Filter Particle & Gas Adsorption Measurement Equipment
Automotive Cabin Air Filter Particle & Gas Adsorption Measurement Equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Fractional efficiency according to ISO 11155-1 (DIN 71460-1) Gas adsorption ...
供应产品

Same products

PanEVAP & MVR system
PanEVAP & MVR system 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...
PanPHE gasketed plate heat exchangers
PanPHE gasketed plate heat exchangers 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanPHE gasketed plate heat exchangersare designed with easy access for regular servicing and for ...