Wire and Cable Smoke Density Tester Manufacturer | IEC 61034 Cable Smoke Density Test Chamber Supplier

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Features

The enclosure consists of a cubic shell with dimensions of 3000mm ± 30mm (length, width, and height). The internal material of the enclosure is SUS 304 stainless steel, filled with calcium silicate fireproof material, and the exterior is made of iron with powder coating;

All internal fixtures are made of stainless steel; aesthetically pleasing and corrosion-resistant;

The total area of the ventilation holes is 50cm² ± 10cm², and they remain open throughout the test; the baffle height is 1000mm;

Equipped with wire and cable test racks and weights as required by the standard.

The test chamber door has glass observation windows on opposite sides, fitted with sealed transparent windows (minimum 100mm x 100mm) that allow light from the horizontal optical measurement system to pass through. These windows are located 2150mm ± 100mm above the ground;

The photocell and light source are positioned at the center of the windows on each of the two walls, without physical contact.

Parameters

Technical ParameterDetails
Operating Voltage AC 220 V ± 10%, 50HZ
Light Source Voltage DC 12V
Power 2000W
Ambient Temperature 25℃ ± 5℃
Nominal Luminous Flux 2000lm ~ 3000lm
Nominal Color Temperature 2800K ~ 3200K
Air Flow Rate ≥ 2L/min
Fire Supply Time Standard time 40min (settable)
Timing Accuracy ≤ 0.5s for 40min
Calibration Value 100% (transmittance)

Test Procedures

Sample Preparation: Cut a cable or optical fiber sample of the specified length (e.g., ≥1 meter) according to the standard, and condition it at 23℃±5℃ for at least 16 hours.

Equipment Calibration: Calibrate the optical system using filters with different transmittances (e.g., 100%, 75%, 25%) to ensure data accuracy.

Sample Installation: Secure the sample horizontally on the support inside the combustion chamber, adjusting its position so that the distance between the lower surface of the sample and the bottom of the alcohol tray is 150mm±5mm.

Environmental Setup: Measure the temperature inside the combustion chamber door at a height of 1.5m-2.0m from the ground and at least 0.2m from the wall to ensure it is within the range of 25℃±5℃; if necessary, preheat the combustion chamber with a blank test.

Test Start: Ignite the alcohol tray fire source, close the combustion chamber door, and start the fan to ensure even distribution of smoke; the test ends when the fire source is extinguished after 5 minutes or after 40 minutes of testing, whichever comes first, or when the transmittance no longer decreases.

Record Results: Read and record the minimum transmittance (Tmin) during the test, and calculate parameters such as specific optical density (Ds).

Equipment Cleaning: After the test, clean the combustion residue and keep the chamber clean.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Athletic Footwear Shock Attenuating Tester
Athletic Footwear Shock Attenuating Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Athletic Footwear Shock Attenuating Tester is primarily used to test the shock energy a...
Industrial Hollow Dummy for Safety and Mechanical Testing
Industrial Hollow Dummy for Safety and Mechanical Testing Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards Toyota, Honda, Nissan; Mercedes-Benz, BMW, Volkswagen; General Motors, Ford; Hyu...
Battery Constant-Temperature Calorimeter
Battery Constant-Temperature Calorimeter Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description Battery Isothermal Calorimeter is a professional instrument developed ...
Battery combustion tester,Battery Cell Fire Tester,IEC 62281
Battery combustion tester,Battery Cell Fire Tester,IEC 62281 Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description Battery combustion tester is a device that can be applied to the safet...
Humidity heat chamber for pv modules
Humidity heat chamber for pv modules Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Damp Heat Test Chamber is suitable for: Damp-heat performance testing of ...
All supplier products

Same products

PanEVAP & MVR system
PanEVAP & MVR system Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...
PanPHE gasketed plate heat exchangers
PanPHE gasketed plate heat exchangers Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanPHE gasketed plate heat exchangersare designed with easy access for regular servicing and for ...