Parameters

ItemSpecification
Quantifiable Gas Species More than 300 compounds
Spectral Range 4500–800 cm⁻¹
Spectral Resolution Better than 1 cm⁻¹
Gas Analysis System Multi-pass gas cell with 5 m optical path
Working Pressure 0–15 bar
Maximum Working Temperature Up to 191 °C
Dedicated Filter Filters dust particles ≥ 2 μm
System Integration 19-inch standard industrial chassis

Features

Wide application flexibility, enabling gas measurements under different pressure and temperature conditions through appropriate accessories.

Optimized high-throughput optical design of the gas cell allows quantitative analysis of mixed gases even at concentrations as low as the ppb level.

No gas calibration is required; the system software automatically retrieves target gas concentrations using nonlinear fitting algorithms.

Effects caused by interfering gases and temperature variations are automatically compensated, ensuring accurate real-time qualitative and quantitative results.

Optical system employs a thermoelectrically cooled detector, CenterGlow™ infrared light source for stable high emission, and a RockSolid interferometer to ensure permanent optical alignment.

Equipped with dedicated sampling probes for gas extraction from pipelines or sealed chambers.

Independent and complete gas analysis software package with an intuitive graphical user interface.

Enables fast, continuous, and fully automated gas identification and quantification without requiring specialized user expertise.

Accessories

(1) Multi-pass gas cell with 5 m optical path

(2) Dedicated gas sampling probe

(3) Dust filtration unit (≥ 2 μm)

(4) Integrated interferometer module

(5) Infrared light source and detector assembly

(6) Industrial control and analysis software package

(7) 19-inch industrial chassis and mounting components

Test Procedures

System Preparation

Install the FTIR system in a stable environment and ensure the gas cell, filter unit, and sampling probe are correctly connected.

Sampling Setup

Insert the dedicated sampling probe into the pipeline, test chamber, or smoke outlet where gas collection is required.

Software Configuration

Launch the gas analysis software and select the corresponding measurement or monitoring mode according to the test objective.

Gas Measurement

Gas samples are continuously introduced into the multi-pass gas cell, where infrared spectra are collected and processed in real time.

Data Analysis and Output

The software automatically performs qualitative identification and quantitative analysis of gas components and displays real-time concentration results, which can be stored or exported for further evaluation.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Automatic Scratch Test machine,ASTM C1624  abrasion and scratch evaluation tester
Automatic Scratch Test machine,ASTM C1624 abrasion and scratch evaluation tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automatic Scratch Test Machine is a precision testing instrument designed to evaluate t...
Battery Adiabatic Calorimeter丨Battery Adiabatic Calorimeter tester
Battery Adiabatic Calorimeter丨Battery Adiabatic Calorimeter tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Reference Standards GB/T 36276 - 2023 *Lithium - ion Batteries for Electric Power Energy S...
Digital display electronic ink viscosity meter
Digital display electronic ink viscosity meter Whats/App: +86 156 1874 6768 Web: standard-groups.com How it works: The working principle of the digital display electronic ink viscosity meter ...
Safety Helmet Impact Acceleration Tester
Safety Helmet Impact Acceleration Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The safety helmet impact acceleration tester is an instrument used to test the performance ...
ASTM D6413 flame spread tester
ASTM D6413 flame spread tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Flame Spread Calorimeter is suitable for: Building materials: Evaluate fl...
All supplier products

Same products

ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire Seller: 868776 Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing high-quality welding mate...
Choosing the Right Equipment for Heavy-Duty Cleaning
Choosing the Right Equipment for Heavy-Duty Cleaning Seller: Taizhou Feike Mechanical Technology Co., Ltd. FEIKE’s High Pressure Washer is designed for industrial cleaning, equipment maintenance, ve...
ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire Seller: 868776 Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin...
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line Seller: Shandong HUASU Plastic Technology Co.,Ltd. The molds adopt the double flow channel structure and nitriding polishing processed die head. Thi...
PanEVAP & MVR system
PanEVAP & MVR system Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...