Gas Explosion Pressure Test Apparatus Manufacturer
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Parameters
| Unit | Specification |
|---|---|
| Explosion Pressure Acquisition | Dynamic data acquisition card, 24-bit resolution, 128 KS/s sampling frequency |
| Chamber Interior | Built-in 19-inch touch screen, integrated electrical control circuits for mobility |
| Test Container | Sphere structure, internal volume ≈ 20 L, internal radius 168 mm, wall thickness 12 mm, stainless steel, max. pressure 3 MPa |
| Chamber Pressure Rating | Maximum 3 MPa, constant endurance ≥ 2 MPa, engineering safety valve rated 2.5 MPa |
| Ignition Electrode | Center-mounted, diameter 4 mm, tip angle 60°, distance between tips ≈ 5 mm |
| Thermocouple | K-type armored, range 0–1000 °C, accuracy 0.1 °C |
| Explosion Container Dimensions | 1800 (L) × 750 (D) × 1750 (H) mm |
| Control Box Dimensions | 650 (W) × 675 (D) × 1750 (H) mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Weight | Approx. 330 kg |
| Auxiliary Gas Source | Nitrogen |
Accessories
Stainless steel spherical test container
Explosion-proof observation window
Ignition electrode assembly
K-type armored thermocouple with flange and ferrule interfaces
Siemens PLC and analog modules
19-inch touch screen
Electrical control cabinet with industrial PC and data acquisition modules
Manual ball valve
Safety pressure relief valve (2.5 MPa)
Auxiliary nitrogen supply interface
Test Procedures
Ensure the chamber is evacuated and all connections are secure.
Fill the test container with the desired gas sample to the required concentration.
Activate the PLC-controlled system to monitor temperature and pressure in real time.
Initiate ignition via the central electrode.
Observe internal explosion event through the explosion-proof window.
Record pressure, temperature, explosion slope, and rise rate via dynamic data acquisition system.
Collect gas samples post-test using manual ball valve for further analysis.
Export all recorded data for report generation in Excel, Word, or PDF format.
Maintenance Information
Inspect and clean the ignition electrode regularly to remove carbon deposits.
Verify thermocouple calibration and replace if necessary.
Check all ports, flanges, and threaded interfaces for gas-tight integrity.
Ensure PLC, data acquisition modules, and industrial PC are operating correctly.
Clean observation window to maintain visibility during tests.
Test safety valves and pressure relief systems periodically for proper functionality.
Send product request
Other supplier products
| Stoll Quartermaster abrasion tester丨Stoll Quartermaster abrasion test chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Stoll Quartermaster can conduct flat grinding, curved grinding, edge grinding, fold gri... | |
| KES-SESRU surface roughness/friction tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheRoughness/Friction Tester analyzes hand movements-particularly, strokes-performed by art... | |
| Metal Wire Repeated Bending Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Metal Wire Repeated Bending Tester is designed to evaluate the bending fatigue performa... | |
| Luggage lifting and unloading testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The luggage simulation lifting and unloading tester is a measuring instrument for the life ... | |
| Automotive Interior Burning Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction The Automotive Interior Burning Tester is designed according to ISO37... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |













