Gas Explosion Pressure Test Apparatus Manufacturer
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Parameters
| Unit | Specification |
|---|---|
| Explosion Pressure Acquisition | Dynamic data acquisition card, 24-bit resolution, 128 KS/s sampling frequency |
| Chamber Interior | Built-in 19-inch touch screen, integrated electrical control circuits for mobility |
| Test Container | Sphere structure, internal volume ≈ 20 L, internal radius 168 mm, wall thickness 12 mm, stainless steel, max. pressure 3 MPa |
| Chamber Pressure Rating | Maximum 3 MPa, constant endurance ≥ 2 MPa, engineering safety valve rated 2.5 MPa |
| Ignition Electrode | Center-mounted, diameter 4 mm, tip angle 60°, distance between tips ≈ 5 mm |
| Thermocouple | K-type armored, range 0–1000 °C, accuracy 0.1 °C |
| Explosion Container Dimensions | 1800 (L) × 750 (D) × 1750 (H) mm |
| Control Box Dimensions | 650 (W) × 675 (D) × 1750 (H) mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Weight | Approx. 330 kg |
| Auxiliary Gas Source | Nitrogen |
Accessories
Stainless steel spherical test container
Explosion-proof observation window
Ignition electrode assembly
K-type armored thermocouple with flange and ferrule interfaces
Siemens PLC and analog modules
19-inch touch screen
Electrical control cabinet with industrial PC and data acquisition modules
Manual ball valve
Safety pressure relief valve (2.5 MPa)
Auxiliary nitrogen supply interface
Test Procedures
Ensure the chamber is evacuated and all connections are secure.
Fill the test container with the desired gas sample to the required concentration.
Activate the PLC-controlled system to monitor temperature and pressure in real time.
Initiate ignition via the central electrode.
Observe internal explosion event through the explosion-proof window.
Record pressure, temperature, explosion slope, and rise rate via dynamic data acquisition system.
Collect gas samples post-test using manual ball valve for further analysis.
Export all recorded data for report generation in Excel, Word, or PDF format.
Maintenance Information
Inspect and clean the ignition electrode regularly to remove carbon deposits.
Verify thermocouple calibration and replace if necessary.
Check all ports, flanges, and threaded interfaces for gas-tight integrity.
Ensure PLC, data acquisition modules, and industrial PC are operating correctly.
Clean observation window to maintain visibility during tests.
Test safety valves and pressure relief systems periodically for proper functionality.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| ASTM E537 Thermal Stability Screening Calorimeter | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)SN/T 3078.1: Standard Sample Management Specifications for Impo... | |
| Filter Media Test System,ISO 5011 filter media performance tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Test System for multiple parameter testing at filter media, space-saving design by vertical... | |
| Airbag-Type Contact Pressure Tester,inflatable sensor contact pressure tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Airbag-Type Contact Pressure Tester is designed to evaluate contact pressure between ga... | |
| Luggage rod reciprocating fatigue meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: Luggage rod reciprocating testing machine for luggage rod reciprocat... | |
| Automotive Sunshade Assembly Line Manufacturer China | Car Sun Visor Production System Factory Direct | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features Automated assembly reduces manual labor and improves production eff... |