Spinal Pedicle Screw-Rod System Compressive Fatigue Testing Machine
Standard
- YY/T 0857-2011 (China): Specifies compression fatigue testing protocols for spinal pedicle screw-rod systems, including load ratios, frequency, and failure criteria.
- YY/T 1560-2017 (China): Defines methodologies for evaluating the fatigue strength of spinal implant assemblies under complex loading.
- ASTM F1717-18 (International): Standard test methods for spinal implant constructs in vertebrectomy models.
- ASTM F2706-19: Specifies static and fatigue testing requirements for occipito-cervical and occipito-cervico-thoracic spinal implants.
Product Advantages
- High-Frequency Stability: Advanced electromagnetic actuator maintains 0.1–15 Hz frequency range with ±0.05% force accuracy.
- Ultra-Precision Loading: 50 kN axial force capacity with 1 N resolution for submicron displacement control.
- Dynamic Load Control: Programmable R=0.1–10 load ratios with real-time stiffness compensation.
- Biorelevant Environment: Temperature-controlled (37±1°C) lubrication bath with 20±2 g/L protein concentration.
- Extended Durability: Capable of 10+ million cycle testing with <0.2% drift in calibration.
- Modular Design: Six-station configuration allows parallel testing of multiple specimens.
Product Features
- Electromagnetic Servo Motor: 50 kN axial force capacity with programmable load ratios (R=0.1–10).
- Triaxial Strain Gauge: Measures axial/radial strains simultaneously (0.1 με resolution).
- Dynamic Load Control: 0.1–15 Hz frequency range with programmable waveforms (sine, square, random, custom).
- Thermal-Mechanical Chamber: ±0.3°C temperature stability with integrated humidity control (10–95% RH).
- High-Resolution Imaging: Optional integration with micro-CT systems for in-situ crack analysis.
- Safety System: Emergency stop, overload clutches, and laser-based specimen breakage detection.
Technical Parameters
| Parameter | Specification |
|---|---|
| Max. Axial Force | ±50,000 N (50 N resolution) |
| Frequency Range | 0.1–15 Hz (0.01 Hz increments) |
| Load Ratio (R) | 0.1–10 (adjustable) |
| Axial Displacement | ±15 mm (0.1 μm resolution) |
| Temperature Control | -20°C to +50°C (PT1000 sensors) |
| Humidity Control | 10–95% RH (non-condensing) |
| Data Sampling Rate | 100 kHz (synchronized across 16 channels) |
| Power Requirements | 220V/110V ±10%, 50/60Hz, 3,500W |
| Dimensions (W×D×H) | 2,200 × 1,600 × 2,300 mm |
| Weight | 1,350 kg (including environmental chamber) |
| Noise Level | <65 dB (A-weighted) |
Accessories
- Spinal Implant Fixture Kit:
- Self-centering pedicle screw clamps (4.5–7.5 mm diameter compatibility)
- Rod-bending jigs with laser-aligned loading anvils
- Thermal-Mechanical Chamber:
- 25L capacity with rapid cooling/heating (15°C/min)
- 316L stainless steel interior with HEPA filtration
- CompressionMaster Pro Software:
- Automated stiffness degradation tracking and fatigue limit calculation
- 21 CFR Part 11-compliant audit trail with blockchain timestamping
- Remote monitoring via dedicated iOS/Android app
- Operator Kit:
- Calibrated torque wrench set (0.5–50 Nm)
- Specimen alignment gauges (ASTM F1717 compliant)
- Calibration Bundle:
- NIST-traceable force calibration weights
- Strain gauge verification tool
- Safety Kit:
- Laser safety curtains
- Acoustic enclosure with 30 dB noise reduction
Send product request
Other supplier products
| Mask Tensile Testing Machine | Standards: GB/T 3917.2 Textiles-Tear properties of fabrics-Part 2 Determination of tear force of pants shaped test specimens (single slit) GB/T ... | |
| FPC Flex Durability Tester | Technical parameters: 1. Test station :1 2, test Angle: 10-180 degrees (touch screen digital setting) 3, test speed :10-120 times/min (touch... | |
| Single Wire Cable Burning Tester | Single Wire Cable Burning Tester - Electrical test equipment price quotation - standard Standards: GB/T 18380.11-2008 Vertical flame spread tes... | |
| Fabric Vertical Flame Spread Performance Tester | Fabric Vertical Flame Spread Performance Tester - Flammability Testing equipment price quotation - standard Standards: GB/T 5456-2009 Textiles-... | |
| Point-to-point Resistance Tester EN 1149?1?1995 GB/T 1410?2006 | Standards GB12014-2009. GB/T 1410-2006. ASTM D257-99. GB/T 10581?2006. GB/T 1692?2008. GB/T 2439?2001. GB/T 12703.4?2010. GB/T 10064?2006. GB/T 22... |
Same products
| Full-Body Garment Stress Tester,FZ/T 70015 | Seller: Standard International Group (HK) Limited | TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe... | |
| Industrial Dry Cleaning Machine,industrial garment steamer | Seller: Standard International Group (HK) Limited | TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel... | |
| MST Medical Compression Stocking Tester,compression sock tester | Seller: Standard International Group (HK) Limited | The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the... | |
| MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool | Seller: Standard International Group (HK) Limited | Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi... | |
| Dental material color stability tester | Seller: Standard International Group (HK) Limited | Application The applications of color stability testers for dental materials are mainly reflecte... |