F-theta Lenses
The F-thetascanning lenses are commonly used in laser scanning systems that employ two-axis galvanometers to scan a specified area but cannot tolerate the angle at the image plane. By introducing a specified amount of barrel distortion in a scanning lens, thetelecentric f theta lensbecomes an ideal choice for applications that require a flat field on the image plane such as laser scanning, marking, engraving and cutting systems. Depending on the requirements of the application, these diffraction limited lens systems can be optimized to account for wavelength, spot size, and focal length, and distortion is held to less than 0.25% throughout the field of view of the lens.
Hyperion OpticsOff-the-shelf FTheta Scan Lens:
Part No. |
Scan Field |
Input Beam |
Focus Spot |
Thread |
M1-M2 |
WD |
Window |
||
EFL (mm) |
Ф(1/e2) |
Ф(1/e2) |
(±deg) |
(mm) |
(mm) |
Dia×Thk |
|||
(mm) |
(mm) |
(μm) |
(mm) |
||||||
HYPQ |
100 |
50x50 |
15 |
13 |
M85x1 |
131 |
|||
HYPQ |
163 |
94x94 |
20 |
23 |
M85x1 |
26 |
|||
HYPQ |
163 |
112x112 |
10 |
30 |
25 |
M85x1 |
|||
HYPQ-D20 |
255 |
170x170 |
20 |
24 |
28 |
M85x1 |
150x3 |
||
HYPQ |
277 |
142x142 |
15 |
21 |
M85x1 |
26 |
|||
HYPQ-D20 |
340 |
215x215 |
20 |
32 |
25 |
M85x1 |
27 |
||
HYPQ-D30 |
460 |
220x220 |
30 |
44 |
25 |
M98x1 |
43 |
144x4 |
|
HYPQ |
420 |
280x280 |
14 |
27 |
M85x1 |
17 |
|||
HYPQ |
450 |
320x320 |
14 |
45 |
25 |
M85x1 |
15 |
||
HYPQ-D30 |
500 |
280x280 |
30 |
34 |
M85x1 |
37 |
|||
HYPQ-D20 |
500 |
340x340 |
20 |
M85x1 |
26 |
||||
HYPQ |
640 |
350x350 |
10 |
M85x1 |
16 |
||||
HYPQ-D20 |
875 |
425x425 |
20 |
M85x1 |
26 |
||||
Part No. |
Scan Field |
Input Beam |
Focus Spot |
Thread |
M1-M2 |
WD |
Window |
||
EFL (mm) |
Ф(1/e2) |
Ф(1/e2) |
(±deg) |
(mm) |
(mm) |
Dia×Thk |
|||
(mm) |
(mm) |
(μm) |
(mm) |
||||||
HYPQ-D20 |
260 |
160x160 |
20 |
30 |
23 |
M85x1 |
27 |
130 |
|
HYPQ-D20 |
335 |
215x215 |
20 |
35 |
24 |
M85x1 |
27 |
200 |
|
HYPQ |
280x280 |
14 |
M85x1 |
17 |
|||||
HYPQ-D20 |
640 |
400x400 |
20 |
64 |
M85x1 |
27 |
556 |
||
HYPQ-D30 |
450x450 |
30 |
103 |
25 |
M123x1 |
37 |
220x5 |
||
Part No. |
Scan Field |
Input Beam |
Focus Spot |
Thread |
M1-M2 |
WD |
Window |
||
EFL (mm) |
Ф(1/e2) |
Ф(1/e2) |
(±deg) |
(mm) |
(mm) |
Dia×Thk |
|||
(mm) |
(mm) |
(μm) |
(mm) |
||||||
HYP |
163 |
60x60 |
14 |
29 |
25 |
M85x1 |
18 |
||
Part No. |
Scan Field |
Input Beam |
Focus Spot |
Thread |
M1-M2 |
WD |
Window |
||
EFL (mm) |
Ф(1/e2) |
Ф(1/e2) |
(±deg) |
(mm) |
(mm) |
Dia×Thk |
|||
(mm) |
(mm) |
(μm) |
(mm) |
||||||
HYP |
163 |
100x100 |
12 |
M85x1 |
20 |
85x2 |
|||
HYP |
260 |
180x180 |
15 |
28 |
M85x1 |
20 |
123x3 |
||
HYPB |
254 |
150x150 |
30 |
110 |
25 |
M102X1 |
43 |
128x4 |
|
HYP |
163 |
100x100 |
12 |
21 |
25 |
M85x1 |
14 |
84x2 |
|
HYP |
254 |
175x175 |
15 |
25 |
28 |
M85x1 |
16 |
120x3 |
|
Part No. |
Scan Field |
Input Beam |
Focus Spot |
Thread |
M1-M2 |
WD |
Window |
||
EFL (mm) |
Ф(1/e2) |
Ф(1/e2) |
(±deg) |
(mm) |
(mm) |
Dia×Thk |
|||
(mm) |
(mm) |
(μm) |
(mm) |
||||||
HYP |
163 |
100x100 |
10 |
M85x1 |
13 |
121 |
|||
Part No. |
Scan Field |
Input Beam |
Focus Spot |
Thread |
M1-M2 |
WD |
Window |
||
EFL (mm) |
Ф(1/e2) |
Ф(1/e2) |
(±deg) |
(mm) |
(mm) |
Dia×Thk |
|||
(mm) |
(mm) |
(μm) |
(mm) |
||||||
HYP |
400 |
200x200 |
30 |
20 |
M85x1 |
36 |
|||
Part No. |
Scan Field |
Input Beam |
Focus Spot |
Thread |
M1-M2 |
WD |
Window |
||
EFL (mm) |
Ф(1/e2) |
Ф(1/e2) |
(±deg) |
(mm) |
(mm) |
Dia×Thk |
|||
(mm) |
(mm) |
(μm) |
(mm) |
||||||
HYP |
170 |
90x90 |
10 |
14 |
M85x1 |
20 |
|||
HYP |
220 |
110x110 |
10 |
M85x1 |
13 |
90x3 |
|||
HYP |
328 |
212x212 |
6 |
45 |
M85x1 |
13 |
104x3 |
||
Part No. |
Scan Field |
Input Beam |
Focus Spot |
Thread |
M1-M2 |
WD |
Window |
||
EFL (mm) |
Ф(1/e2) |
Ф(1/e2) |
(±deg) |
(mm) |
(mm) |
Dia×Thk |
|||
(mm) |
(mm) |
(μm) |
(mm) |
||||||
HYP |
170 |
90x90 |
10 |
M85x1 |
20 |
||||
Part No. |
Scan Field |
Input Beam |
Focus Spot |
Thread |
M1-M2 |
WD |
Window |
||
EFL (mm) |
Ф(1/e2) |
Ф(1/e2) |
(±deg) |
(mm) |
(mm) |
Dia×Thk |
|||
(mm) |
(mm) |
(μm) |
(mm) |
||||||
HYP |
178 |
110x110 |
10 |
15 |
M85x1 |
13 |
106x3 |
In addition to these standard f theta lens designs, we can develop complete systems for you, use components from laser beam shaping to the expansion and splitting of laser beams.
If you want to know more details of optical design manufacturing, please visit our website.
Send product request
Other supplier products
Dichroic Filter | Hyperion's optical design manufacturingcapabilities span across the spectrum. From UV, VIS, to IR, we fabricate custom optical components that meet... | |
Penta Prism | Penta Prisms are used to define right angles in optical systems. Penta Prisms, which provide right handed images, feature a ray deviation of 90°... | |
Dichroic Filter | Hyperion Optics’s complete range of cost effective dichroic filterrange offers superior transmission, reflection and absorption characteristi... | |
Notch Filter | Hyperion Optics is a premium full-service photonics supplier. Hyp designcapabilities can meet the unique requirements of various customers. The no... | |
Multichannel Filter | Multichannel filterdiffer from conventional bandpass filters by allowing only one continuous band of light to pass through it, allowing two or more... |
Same products
Achromatic Lens | Seller: TianCheng Optics CO.,Ltd | Achromatic Lensfor Sale An achromatic lensis a lens that is designed to limit the effects of chr... | |
GH-SW640Pro-U3 SWIR Camera | Seller: GHOPTO | GH-SW640Pro-U3 SWIR Camera The SWIR Cameraseries feature a 640 x 512 pixel InGaAs focal plane ar... | |
WELINK MTP/MPO Adapters | Seller: SHENZHEN WELINK TECHNOLOGY CO., LTD. | MTP/MPO Adapters can accurately connect two connectors and reduce connection loss, mainly used fo... | |
WELINK MTP/MPO Cabels | Seller: SHENZHEN WELINK TECHNOLOGY CO., LTD. | MPO/mtp fiber optic cableare designed to avoid crowding and unmanageable data centers, consist of... | |
Micro Data Centre | Seller: SHENZHEN WELINK TECHNOLOGY CO., LTD. | A micro data center(MDC) is a small modular data center designed for computer workloads that do n... |