Y5WZ-17-45 AC Gapless MOA

AC gapless metal oxide arrester(hereinafter referred to as arrester) is used to protect AC electrical equipment of corresponding voltage level from lightning overvoltage and operating overvoltage damage.

indoor AC gapless metal oxide arrester(hereinafter referred to as arrester) is used to protect AC electrical equipment of corresponding voltage level from lightning overvoltage and operating overvoltage damage.

Product Implementation Standard: GB11032 - 2010 "AC Gapless Metal Oxide Arrester".

This kind of arrester is assembled by superposition of non-linear zinc oxide resistors and sealed in high voltage insulating ceramic sleeve without any discharge gap.Under normal operating voltage, the arrester is insulated with high resistance; when it is impacted by overvoltage, the arrester is in low resistance state, releasing impulse current into the ground quickly, so that the voltage on the electrical equipment parallel to it is limited to the prescribed value, so as to ensure the safe operation of the electrical equipment.The arrester is equipped with a detachment device. When the arrester operates under overload or suffers accidental damage, the internal pressure increases sharply, so that the arrester can be detached from the device to ensure that the ceramic sleeve is not damaged.The arrester has the characteristics of good steep wave response, high shock current tolerance, low residual voltage, reliable operation, no power frequency continuous current, simple maintenance and so on.

  1. arrestershould be prevented before it is put into operation and before the thunderstorm season every year.

Sex testing tests, the items are:

(1) DC or power frequency reference voltage test:

When the peak value of DC or AC resistive current flowing through the arrester reaches the reference current, read the voltage value, which is not less than the standard value.

(2) DC leakage current test:

The DC voltage value of 0.75U1mA is applied at both ends of the arrester (the voltage ripple rate is not more than (+1.5%). When the voltage is stabilized, the leakage current flowing through the arrester should not be greater than the standard value. The leakage current of the surge arrester in operation should be no more than 2 times of the measured value before commissioning.

(3) Detection of power frequency persistent current value:

Power Frequency Continuous Current Value, Leakage Current Tester or Sufficient for Use of Arresters

Accurate AC meter detection shows that the RMS or peak resistance current flowing through the arrester under operating power frequency voltage does not exceed 1.5 times of the initial measurement value.

Ⅵ. Attention:

(1) During transportation and storage, arresters should be placed vertically.

(2) Users are not allowed to disassemble lightning arresters at will.

(3) Users are not allowed to test the working frequency discharge voltage of the arrester in order to avoid damage to the arrester.

(4) Under the condition that users abide by the above rules, our factory is responsible for the three-package matters within the three-package period, which is one year.

If users have special needs, they can write to them. We will supply as required.

If you have any question on Industrial frequency converter cabinet, plc control cabinet. We will give the professional answers to your short questions. If you need, welcome to contact us to know more!



Отправить запрос, связаться с поставщиком

Кому: Wisdom Automatic Equipment (Wuxi) Co., Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

WSD-FLW34-24 SF6 load switch
WSD-FLW34-24 SF6 load switch WSD-FLW34-24 SF6 load switch WSD-FLW34-24 SF6 load switch is suitable for outdoor three-phase AC distribution systemwith rated voltage of 24 kV and...
XL-21 low-voltage power distribution cabinet
XL-21 low-voltage power distribution cabinet XL-21 low-voltage power distribution cabinet Overview XL-21 Low Voltage Switch Cabinetis suitable for power plant, industry and mining enterprises....
KYN28-24 Indoor AC Metal Armored Pull-out Switchgear
KYN28-24 Indoor AC Metal Armored Pull-out Switchgear KYN28-24 Indoor AC Metal Armored Pull-out Switchgear KYN28A-24 indoor AC metal armoured pull-out switch cabinet is suitable for three-phase AC 50/6...
PLC control cabinet
PLC control cabinet PLC control cabinet PLC control cabinetis an electric cabinet with PLC as the core control unit, which can realize the control of fans, pumps, ele...
WSD-YBW series Prefabricated Substation
WSD-YBW series Prefabricated Substation WSD-YBW series Prefabricated Substation Overview WSD-YBW series Prefabricated Substation is a series of products designed and developed by our comp...
Все товары поставщика

Похожие товары

Made in China Pressure Switch HC0622-24 for thermal power plant
Made in China Pressure Switch HC0622-24 for thermal power plant Продавец: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "Made in China Pressure Switch HC0622-24 for thermal power plant YOYIK professional production an...
Gas Torch
Gas Torch Продавец: Ningbo Shuai Xian Regulator Co., Ltd Introduction Set packed with hoses, regulator arm support of gas Torch Gas blow torchSpecific...
Gas Regulator Connector
Gas Regulator Connector Продавец: Ningbo Shuai Xian Regulator Co., Ltd barbecue gas connectorused in conjunction with a cylinder valve to deliver an unreduced pressure ...
Gas Regulator Accessories, Gas Hose Fitting & Torch
Gas Regulator Accessories, Gas Hose Fitting & Torch Продавец: Ningbo Shuai Xian Regulator Co., Ltd Integrated Gas Technologies(IGT®) supplies gas regulator outlet fittinglike gas regulator hos...
Gas Regulator
Gas Regulator Продавец: Ningbo Shuai Xian Regulator Co., Ltd Integrated Gas Technologies(IGT®) is a global gas control equipment company founded 2006 exce...