Transient Hot-Wire Liquid Thermal Conductivity Analyzer
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Transient Hot-Wire Liquid Thermal Conductivity Analyzer is a precision instrument designed for accurate measurement of thermal conductivity, thermal diffusivity, and specific heat of liquids, pastes, and powders. Based on the transient hot-wire (THW) method and compliant with ASTM D7896-19. the system enables fast, reliable, and repeatable thermal property characterization using a small sample volume and ultra-short measurement time. It is especially suitable for liquid and phase change material analysis under a wide temperature and pressure range.
Application
The Transient Hot-Wire Liquid Thermal Conductivity Analyzer is widely used in research, development, and quality control environments where accurate thermal property data of fluids and semi-fluids is required. Typical application scenarios include:
Engine coolants, lubricants, and heat transfer fluids
Phase change materials (PCM) for thermal energy storage
Chemical liquids and pastes used in process engineering
High-viscosity fluids and suspensions
Research on thermal transport mechanisms
Typical tested products include engine coolants, PCM slurries, silicone oils, polymer solutions, and specialty chemical fluids.
Standards
The analyzer is designed and tested in accordance with internationally recognized standards:
(1) ASTM D7896-19 — Standard Test Method for Thermal Conductivity, Thermal Diffusivity, and Volumetric Heat Capacity of Liquids Using the Transient Hot-Wire Method
Parameters
| Parameter | Configuration 1 | Configuration 2 | Configuration 3 |
|---|---|---|---|
| Material | Liquids & phase change materials | Liquids & phase change materials | Liquids & phase change materials |
| Thermal Conductivity (W/m·K) | 0.01 – 2 | 0.01 – 2 | 0.01 – 2 |
| Additional Properties | Thermal diffusivity, specific heat | Thermal diffusivity, specific heat | Thermal diffusivity, specific heat |
| Viscosity Range (cP) | 0.001 – 10.000.000 | 0.001 – 10.000.000 | 0.001 – 10.000.000 |
| Sample Volume (mL) | 20 | 20 | 20 |
| Test Time (s) | 1 | 1 | 1 |
| Accuracy (Thermal Conductivity)* | ±2% | ±2% | ±2% |
| Repeatability (Thermal Conductivity)* | ±1% | ±1% | ±1% |
| Temperature Range (°C) | 10 to 200 | -40 to 200 | -160 / -40 / 0 to 300 |
| Pressure (bar) | Up to 20 | Up to 20 | Up to 35 |
| External Cooling Required | No | Yes | Yes |
| Standard | ASTM D7896-19 | ASTM D7896-19 | ASTM D7896-19 |
Features
Transient hot-wire method with ultra-fast 1-second measurement
High accuracy and excellent repeatability for liquid thermal properties
Non-steady-state measurement minimizes convection effects, even for high-viscosity samples
Small sample volume requirement (20 mL)
Wide viscosity, temperature, and pressure measurement capability
Fully compliant with ASTM D7896-19
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Advanced catheter residual vacuum tester instrument | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YY/T 0339 - 2019: Suction Catheters for the Respiratory Tract Features 1. High... | |
| Photovoltaic module backplane peeling strength testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction The Photovoltaic Module Backplane Peeling Strength Testing Machine is a speci... | |
| Automatic Reaction Calorimeter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB 51283 GB/T 22232 GB/T 17802 SN/T 3078.1 Product Features 1. It offers th... | |
| Filter Media Tester G508(Without Vertical Duct), ISO 11057 air filter media efficiency tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Filter Media Filtration Performance Test Bench G508 is designed to evaluate the filtrat... | |
| high precision impact testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Impact Testing Machine is a precision instrument designed for material testing in the a... |