Explosive Gas Lower and Upper Limit Testing Apparatus

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The system complies with the following national and international standards:

GB/T 21844-2008 – Standard Test Method for Flammability Limits of Compounds (Vapors and Gases) (China)

ASTM E918-19 – Standard Test Method for Flammability Limits of Chemicals at Elevated Temperatures and Pressures

ISO 10156 – Gases and Gas Mixtures – Determination of Flammability Limits

EN 1839 – Determination of Flammability Limits of Gaseous Fuels

Parameters

UnitSpecification
Environmental Temperature Adjustable: ambient ~ 200 °C, control accuracy ±1 °C
Sealed Container Standard 8 L stainless steel vessel
High-Precision Pressure Sensor Range: 0–200 kPa (absolute), for precise gas mixing
Conventional Pressure Sensor Range: -0.1~3 MPa, for auxiliary container pressure monitoring
Auxiliary Gas Source Air / Nitrogen / Test gas
Dimensions 800 (W) × 600 (D) × 1300 (H) mm
Power Supply AC 220 V, 50/60 Hz, 10 A
Weight Approx. 150 kg

Features

Equipped with a dedicated gas vacuum pump to evacuate the stainless steel container and perform purging functions.

Container sealed with rubber stopper and pressure relief device to ensure safe operation.

Container interfaces pre-configured for gas mixing, vacuuming, and pressure monitoring, accommodating diverse testing needs.

Reserved temperature sensor port for precise internal temperature measurement.

Internal ignition device controlled externally with interlock protection to prevent accidental ignition during gas mixing.

Observation window enables visual monitoring of test phenomena.

Siemens PLC with analog modules and 7-inch HMI touchscreen allows real-time control, monitoring, and data acquisition for temperature, pressure, gas mixing, and ignition processes.

Accessories

Stainless steel 8 L sealed container

Dedicated vacuum pump

Rubber stopper with pressure relief device

Gas mixing, vacuum, and pressure monitoring interfaces

Internal ignition device with interlock protection

Temperature sensor port

Observation window

Siemens PLC system with analog modules

7-inch HMI touchscreen

Data acquisition and storage modules

Test Procedures

Install the gas sample into the stainless steel container and seal with rubber stopper.

Evacuate the container using the dedicated vacuum pump and purge with inert or test gas as required.

Set the target environmental temperature using the control system.

Mix the gas to the desired concentration using the pre-configured interfaces and monitor with pressure sensors.

Initiate ignition via the internal ignition device; interlock protection prevents accidental ignition during gas mixing.

Observe combustion behavior through the observation window.

Record temperature, pressure, and other relevant data in real time via the PLC and HMI touchscreen.

Store or export data for analysis and reporting.

Maintenance Information

Regularly inspect and clean the container and rubber stopper to ensure tight sealing.

Check and calibrate high-precision and conventional pressure sensors periodically.

Ensure vacuum pump operates efficiently and perform routine maintenance.

Clean observation window to maintain clear visibility.

Verify ignition device and interlock protection system function properly before testing.

Confirm PLC, HMI touchscreen, and data acquisition modules are operational and software is up-to-date.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Socks wear tester
Socks wear tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: Socks wear tester is a special equipment, mainly used to test the we...
 Resistance to flame propagation tester,ECE R118 Annex 10
Resistance to flame propagation tester,ECE R118 Annex 10 Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction This equipment is designed and manufactured according to ECE R118 Annex 10....
Box-Type UV Accelerated Aging Chamber
Box-Type UV Accelerated Aging Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com This test chamber simulates the hazards caused by sunlight exposure and rain. It utilizes f...
Photovoltaic module wire tube bending testing machine
Photovoltaic module wire tube bending testing machine Whats/App: +86 156 1874 6768 Web: standard-groups.com The Photovoltaic Module Wire Tube Bending Testing Machine is designed to evaluate the mecha...
Cylindrical Battery In-Situ Volume Swelling Testing System
Cylindrical Battery In-Situ Volume Swelling Testing System Whats/App: +86 156 1874 6768 Web: standard-groups.com The Cylindrical Battery In-Situ Volume Swelling Testing System is designed for real-time me...
Все товары поставщика

Похожие товары

Высокоскоростная экструзионная линия для производства гофрированных труб с двойными стенками из ПЭВП с водяным охлаждением
Высокоскоростная экструзионная линия для производства гофрированных труб с двойными стенками из ПЭВП с водяным охлаждением Продавец: Shandong HUASU Plastic Technology Co.,Ltd. Формы имеют структуру с двойным каналом потока и фильерную головку, обработанную азотированием и ...
PanEVAP & MVR system
PanEVAP & MVR system Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...