Temperature Humidity Vibration Test Chamber Factory Direct

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

JJF 1101 Calibration Specification for Temperature and Humidity of Environmental Test Equipment

GB/T 5170 Inspection Methods for Environmental Test Equipment for Electrical and Electronic Products

Features

ombined temperature, humidity, and vibration testing to simulate real-world multi-stress environments

High-performance transparent wave door with excellent X-band transmission efficiency

Integrated absorbing wave materials to minimize electromagnetic reflection and standing wave interference

Wide temperature and humidity operating range suitable for extreme environmental testing

High thermal load capacity to support powered test samples during operation

Stable structural design ensuring long-term flatness and mechanical reliability

Parameters

CategoryItemSpecifications
Basic Specifications Nominal Inner Volume 9.5 m³
Inner Chamber Dimensions 2700mm × 1800mm × 1950mm (Depth × Width × Height)
Test Environment Conditions Ambient temperature: 25°C, relative humidity: ≤85% RH, cold water temperature: ≤28°C
Temperature Performance Temperature Range -70°C ~ +100°C
Temperature Fluctuation ≤±0.5°C
Temperature Deviation ≤±2°C
Temperature Uniformity ≤2°C
Temperature Ramp Rate - Heating: ≥10°C/min (equivalent load 1000kg, electric heating power 8kW, average across the whole range; ≥10°C/min from room temperature to -55°C, ≥10°C/min from -55°C to 70°C)- In the range of -55°C ~ +85°C, the chamber can withstand an internal heat load of 8000W- In the range of -55°C ~ +85°C, the chamber can withstand an internal heat load of 3500W and an internal cooling air supply of 100kg/h (air temperature: 2~35°C, dew point temperature: ≤40°C)
Humidity Performance Humidity Range 35% RH ~ 98% RH (adjustable within -20°C ~ 70°C)
Humidification Method Humidification via hot air passing through the test piece; alternating temperature and humidity (typical value: 30°C/60°C, RH95%, temperature change rate ≥85%); constant temperature and humidity (typical value: 35°C, 90% ~ 98%)
Humidity Deviation ≤±3% RH (when humidity >75% RH); ≤±5% RH (when humidity ≤75% RH)
Chamber Front Door Door Configuration Hermetic door with transparent viewport- Temperature resistance: -65°C ~ +105°C- Humidity resistance: 25% ~ 98% RHFunctional performance:1) Working frequency: X-band2) Temperature resistance range: -65°C ~ +105°C3) Humidity resistance range: 25% ~ 98% RH4) Wave transmission rate: >95%5) Standing wave ratio influence: <2%6) Power resistance: 10W/cm²7) Flatness: <2cm (diagonal), no deformation after fabrication8) Fixing method: High-strength adhesive bonding to the chamber frame
Chamber Front End Absorber Material (on Hermetic Door) - Wave transmission rate (X-band): >95% (on left, right, and upper sides)- Power resistance: 10W/cm²- Total mass loss (TWC): ≤0.6%- Volatile condensable material (CVCM): ≤

Accessories

The standard and optional accessories available for your test requirements include:

Vibration interface platform and mounting fixtures

High-strength adhesive bonding system for transparent wave door installation

High and low temperature resistant absorbing wave materials for internal chamber surfaces

Temperature and humidity sensors with calibration support

Safety protection and monitoring modules


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Geosynthetic  creep tester
Geosynthetic creep tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The geosynthetic material creep testing system is used to determine the tensile creep perfo...
Minimum Ignition Energy (MIE) – Dust Cloud Tester
Minimum Ignition Energy (MIE) – Dust Cloud Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Dust Cloud Minimum Ignition Energy Tester disperses a certain mass of dust specimen to be t...
Chest Drainage Tester
Chest Drainage Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The thoracic drainage tester is widely applied in the medical field, mainly used for monito...
High precision scratch resistance tester for coatings and materials
High precision scratch resistance tester for coatings and materials Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Scratch Resistance Testing Instrument is widely used for: Scratch testing...
Automotive HVAC Manikin
Automotive HVAC Manikin Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This system is widely used for: Vehicle heating, ventilation, and air conditi...
Все товары поставщика

Похожие товары

Common Rail Injector Valve F00R J01 334
Common Rail Injector Valve F00R J01 334 Продавец: 868983 Common Rail Injector Valve F00R J01 334 Injector Valve Set F00V C01 361 Injector Valve Set F00V...
Common Rail Injector Valve F 00V C01 371
Common Rail Injector Valve F 00V C01 371 Продавец: 868983 Common Rail Injector Valve F 00V C01 371 Injector Valve Set F00V C01 310 Injector Valve Set F00...
Common Rail Injector Valve F 00V C01 365
Common Rail Injector Valve F 00V C01 365 Продавец: 868983 Common Rail Injector Valve F 00V C01 365 Injector Valve Set F00V C01 303 Injector Valve Set F...
Common Rail Injector Valve F 00V C01 329
Common Rail Injector Valve F 00V C01 329 Продавец: 868983 Common Rail Injector Valve F 00V C01 329 Injector Valve Set F00V C01 054 Injector Valve Set F...
Common Rail Injector Valve F 00V C01 325
Common Rail Injector Valve F 00V C01 325 Продавец: 868983 Common Rail Injector Valve F 00V C01 325 Injector Valve Set F00V C01 044 Injector Valve Set F...