Advanced Contamination Sensitivity Evaluation Equipment
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
The Hydraulic Pump Contamination Resistance Tester is primarily used to test the fuel pump's resistance to contamination when operating in a working medium with a specified concentration of contaminants.
Standards
You can operate this tester in compliance with the following standards:
ISO 23840:2021 — Hydraulic fluid power — Filters — Evaluation of filter performance using multipass test (MPT) — Particulate filtration efficiency.
JB/T 7043-2006 — Hydraulic filter elements — Test method for rupture resistance.
GB/T 44682-2024 — Hydraulic fluid power — Filters — Evaluation of dirt-holding capacity of filter elements using multipass test.
GB/T 14039-2002 — Hydraulic and lubrication system oil cleanliness evaluation.
GJB 1003-1996 — Contamination testing powders and methods for aviation fuel pumps.
Technical Parameters
| No. | Technical Parameters | Specifications |
|---|---|---|
| 1 | Test oil | RP-3 aviation kerosene |
| 2 | Test powder | In accordance with the provisions of Table Ⅱ of GJB1003:1996 |
| 3 | Medium temperature | 10-40°C |
| 4 | Purification cleanliness | /-12/10 (GB/T |
| 5 | Test flow | 150 ~ 750L/min (fuel pump J/RLB-160; fuel pump J/RLB155-011); 250 ~ 1150L/min (fuel pump J/RLB-162) |
| 6 | Test pressure | 0 ~ 1MPa |
| 7 | Fuel tank volume | 1000L |
| 8 | Equipment power supply | AC 380V / 50Hz |
| 9 | Equipment power | 25KW |
| 10 | External dimensions | 5000 × 200 × 2000 (L × W × H) (subject to measurement) |
| 11 | Weight | 1000kg |
Accessoriess
1. Core Functional Components: Mixing oil tank (including agitator), conical working oil tank, circulating pump, bypass circulation and purification assembly, pump housing fixing device, flow measurement device, manual switching valve.
2. Control and Monitoring Components: Control panel, display screen, oil temperature/pressure sensors, electrical control module.
3. Auxiliary Components: Oil receiving pan, pipe fittings, seals (such as O-rings), instruction manual, certificate of conformity.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Medical Intramedullary Nail Fatigue Testing Equipment ASTM Certified | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)YY/T 0591-2011: Chinese standard specifying bending fatigue tes... | |
| Haze meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard The Haze Meter STDYH40 adheres to global standards includingASTM D1003/1044,ISO 1... | |
| Big 45°Method Suture Flame Contact Times Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com This instrument is used for testing flame exposure times of flame retardant protective clot... | |
| Building Material Fire Endurance Test Furnace OEM Manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features The furnace incorporates advanced design and control technology to ... | |
| Battery Nail Penetration Tester丨Battery Nail Penetration Test mechine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Description The test shall be carried out at an ambient temperature of 20°C±5&d... |
Похожие товары
| Filter Efficiency Testing Equipment | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheFilter Efficiency Testing Equipmentis ... | |
| G506 Filter Performance Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM F2100:Standard Specificat... | |
| Automated Filter Integrity Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Testing Standards ASTM F838 – Memb... | |
| High Efficiency Oil Water Separation Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO/TS 16332-2006 – Meth... | |
| DIN 51524 hydraulic oil analyzer | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards You can operate this unit in c... |