Injection Needle
Intended useIndications for endoscopy to introduce a sclerosing agent or vasoconstrictor into selected sites to control actual or potential bleeding lesions in the digestive system; and the injection of saline to aid in Endoscopic Mucosal Resection (EMR),Website:, polypectomy procedures and to control non-variceal hemorrhage.FeaturesInnovational design of metallic tip, efficiently avoid damage to catheter and working channel. Rigid and super-lubricant catheter, easier to pass through the working channel. Unique needle section design, with suitable sharpness and easier for puncture. Ergonomic handle design, easier to operate. SpecificationsModelO.D. (mm)WorkingLength (mm)Needle size (diameter/ length)Endoscope Channel (mm)JHY-INA1.8120022G, 5mm≥2.0JHY-INA1.8180019G, 4mm≥2.0JHY-INA1.8180019G, 5mm≥2.0JHY-INA1.8180019G, 6mm≥2.0JHY-INA1.8180022G, 4mm≥2.0JHY-INA1.8180022G, 5mm≥2.0JHY-INA1.8180022G, 6mm≥2.0JHY-INA1.8180023G, 4mm≥2.0JHY-INA1.8180023G, 5mm≥2.0JHY-INA1.8180023G, 6mm≥2.0JHY-INA1.8180025G, 4mm≥2.0JHY-INA1.8180025G, 5mm≥2.0JHY-INA1.8180025G, 6mm≥2.0JHY-INA2.3230019G, 4mm≥2.8JHY-INA2.3230019G, 5mm≥2.8JHY-INA2.3230019G, 6mm≥2.8JHY-INA2.3230022G, 4mm≥2.8JHY-INA2.3230022G, 5mm≥2.8JHY-INA2.3230022G, 6mm≥2.8JHY-INA2.3230023G, 4mm≥2.8JHY-INA2.3230023G, 5mm≥2.8JHY-INA2.3230023G, 6mm≥2.8JHY-INA2.3230025G, 4mm≥2.8JHY-INA2.3230025G, 5mm≥2.8JHY-INA2.3230025G, 6mm≥2.8JHY-INA2.3230019G, 4mm≥2.8JHY-INA2.3230019G, 5mm≥2.8JHY-INA2.3230019G, 6mm≥2.8JHY-INA2.3230022G, 4mm≥2.8JHY-INA2.3230022G, 5mm≥2.8JHY-INA2.3230022G, 6mm≥2.8JHY-INA2.3230023G, 4mm≥2.8JHY-INA2.3230023G, 5mm≥2.8JHY-INA2.3230023G, 6mm≥2.8JHY-INA2.3230025G, 4mm≥2.8JHY-INA2.3230025G, 5mm≥2.8JHY-INA2.3230025G, 6mm≥2.8
Другие товары поставщика
|
|
SpecificationsModelO.D. (mm)Length (mm)Endoscope Channel (mm)CharacteristicsJHY-FG-18-70-A41.870≥2.0A4:Pelican TeethJHY-FG-23-160-A12.31600≥2.8A1: ... |
|
|
SpecificationsBiopsy ValveModelCharacteristicsJHY-BV-A1Disposable,Website:, for Olympus & Fujinon EndoscopeJHY-BV-B1Disposable, for Pentax Endoscope |
|
|
Intended useIndications for endoscopy to introduce a sclerosing agent or vasoconstrictor into selected sites to control actual or potential bleedin... |
|
|
Features●Made by medical macromolecule,Website:, with proper rigidity.●Equipped with 2 radiopaque marks on each bougie, easy to observe under X-ray... |
|
|
Innovational triple anti-drop design at Hydrophilic tip,Website:, with no risk of drop-off.Anti-twist innerNiti core wire, offering an excellent tw... |
Все товары поставщика
Похожие товары