Miniature Peristaltic Pump
RUNZE FLUID, a professional microfluidic components supplier, offers a complete product range of microfluidic instrumental components including industrial china syringe pump, multiposition valves, plastic fittings, peristaltic pumps, fluidic tubing, gastight syringes, OEM molding parts, which play an important role in fluid analytical instrument prototyping and production, like water, blood, chemicals, diathermic oil, etc. All of our microfluidic components are of extremely high qualities and with reasonable prices, and they are widely used in environmental lab equipment, automated fluid dispensing, medical diagnostic equipment, food analysis instrument, etc.
Miniature Peristaltic Pumphead is very high cost performance model for small flow rate applications like the micro peristaltic pump, small layout, 4 rollers structure and easy tubing replacement make it very welcomed by medical and lab equipment, flexible block designs enable it self-adapt to different tube sizes in a wide range.
Specification of Miniature Peristaltic Pump
Model No. |
RZ1030-4 |
Pump Roller |
POM 4 rollers |
Pump Head |
ABS engineering plastic |
Fast Tubing |
YES |
Pump Color |
Black |
Compatible Motor |
Stepper motor/DC motor |
Motor Speed |
0-500rpm |
Flow Range |
0-170ml/min |
Tubing Size |
|
Tubing Life |
Silicone≥200H BPT Rubber≥1000H |
Pressure Rating |
Up to 2 bar(30psi) |
Working Environment |
0-40℃, <80% non-condensing |
Max DB |
65db |
Suction |
5 meters |
Head |
8 meters |
Dimension (L*W*H) |
57*65*23mm |
Net Weight |
58g |
Fitting Peristaltic Tubing of Miniature Peristaltic Pump
Material |
Features |
Service Life |
Silicone |
Food grade, High flexibility For non-corrosive liquid |
≥200h |
Pharmed BPT |
Saint-Gobain, FDA standard Anti weak acid and alkali |
≥1000h |
Viton |
MasterFlex, FDA Standard Anti strong acid and alkali |
≥1000h |
- ℃ and no extra pressure until it cracks
How do micro peristaltic pumps work?
The mini peristaltic pump is a low-pressure product pump, the general working pressure does not exceed 0.7Mpa, and the large peristaltic pump (hose pump) can reach more than 1Mpa. The miniature peristaltic pumpsalternately squeeze and release the elastic delivery hose of the pump, so that the peristaltic pump draws fluid. Just like pinching and squeezing a hose with two fingers, the hose moves with the fingers, and the liquid creates a negative pressure in the hose. There are many types of fluids transmitted by micro peristaltic pumps, not only fluids with particles, but also fluids with strong acids, strong bases and strong organic solvents. You only need to choose a hose suitable for the fluid.
What are the advantages of using a micro peristaltic pump?
- micro peristaltic pump price: miniature peristaltic pump head discs are usually made of plastic to reduce costs.
How to maintain a micro Peristaltic Pump?
The composition of the mini peristaltic pump is divided into three components: the driver, the pump head, and the hose. During use, the hose is consumable and needs to be replaced regularly. The driver and pump head are maintenance-free parts, and only need to be dry and cleaned daily.
Work without special maintenance.
In the use of the miniature peristaltic pump head, the common damages include the following situations, which need to be paid attention to during use: First, the speed is too high, exceeding the design speed requirements of the pump head; Second, accidental fall from high altitude, resulting in deformation or damage of the pump head; Third, the leakage of the hose causes the liquid to enter the rollers of the pump head and the main shaft bearing, and damage the bearings.
Send product request
Other supplier products
Multi Channel Syringe Pump | Multi channel syringe pumpis aprecision syringe pumpspecially designed for high precision liquid handling with a small footprint applied in limite... | |
Peristaltic Pump Head | peristaltic pump headis the most important part for a full unit peristaltic pump, it is responsible to drive the suitable tubes to reach specific ... | |
Stepper Motor Peristaltic Pump | Stepper peristaltic pump motoris the most important part for a full unit peristaltic liquid pump, it is responsible to drive the suitable tubes to ... | |
Switching Valve | The switching valve is a type of multiport valve without a public port but with dispensing ports around, a sample loop is required for such kind of... | |
Laboratory Peristaltic Pump | Laboratory Peristaltic Pump is a bench-top typeperistaltic liquid pumpsuitable for laboratories and production line to filling bottles or fluid me... |
Same products
Common Rail injector control valve F00V C01 365 & Common Rail injector control valve F00V C01 368 | Seller: zhonglutong | Common Rail injector control valve F00V C01 365 Common Rail injector control valve F00V C01 368 C... | |
Common Rail injector control valve F00V C01 362 & Common Rail injector control valve F00V C01 363 | Seller: zhonglutong | Common Rail injector control valve F00V C01 362 Common Rail injector control valve F00V C01 363 C... | |
Common Rail injector control valve F00V C01 358 & Common Rail injector control valve F00V C01 359 | Seller: zhonglutong | Common Rail injector control valve F00V C01 358 Common Rail injector control valve F00V C01 359 C... | |
Common Rail injector control valve F00V C01 355 & Common Rail injector control valve F00V C01 356 | Seller: zhonglutong | Common Rail injector control valve F00V C01 355 Common Rail injector control valve F00V C01 356 C... | |
Common Rail injector control valve F00V C01 352 & Common Rail injector control valve F00V C01 353 | Seller: zhonglutong | Common Rail injector control valve F00V C01 352 Common Rail injector control valve F00V C01 353 C... |