.

CT/X-Ray Contrast Media

The main component of CT/X-ray Contrast Media is iodine. The Iodinated Contrast Media is a colorless, transparent, slightly viscous liquid. At present, the CT contrast agents can be mainly divided into ionic and non-ionic, according to the osmotic pressure can be divided into hypertonic, isotonic and hypotonic. Currently, non-ionic, isotonic or hypotonic Contrast Media are used clinically. When the CT contrast mediumis injected, 97% of the contrast media products can be directly excreted from the kidneys within 1 day. Apart from contrast media products, we also provide calcobutrol sodium for different use.

Types of Contrast Aents in CT/X-ray

Iohexol Injection

Iohexol Injection is non-ionic contrast agent. Compared with traditional ionic contrast agent, Iohexol Injection has the excellent molecular structure, it has greatly improved safety, and significantl...

Iopamidol Injection

Iopamidol Injection is the second-generation non-ionic iodinated contrast media launched in the global market. In 2015, Beilu firstly launched and listed this product in the Chinese market. Product name: Iopam...

Iodixanol Injection

Iodixanol Injection is a Contrast Media that is isotonic with plasma. It has excellent cardiac safety and renal safety, which is most comfortable to use, especially suitable for high risk patients.

Reasonable Use of Iodinated Contrast Agents

Evaluate patient benefits/risks before use

History of allergies: Patients who have previously experienced moderate to severe anaphylactoid reactions to iodinated contrast agents or patients with a history of allergies requiring treatment are at an increased risk of having an allergic reaction to CT scan contrast dye.

Kidney function: iodinated contrast agents can cause acute kidney injury, and patients should be evaluated for related risks before the surgery.

Combination medication: drugs that may increase the risk of adverse reactions to iodinated contrast agents: neuroleptics and antidepressants, interleukin-2, beta-blockers, metformin.

Situations where iodinated contrast agents should be used with caution: lung and heart diseases, catecholamine secreting tumours, pregnant and lactating women, myeloma and macroglobulinemia, myasthenia gravis, homocystinuria. You can see more in the visipaque package insert.

Contraindication: uncured patients with hyperthyroidism.

Dose limit for iodinated contrast agents

On the premise of satisfying imaging/diagnosis, the minimum dose of iodinated contrast agents should be used.

For low-risk patients, the total dose of types of contrast agents had better be controlled within 300 ~ 400 ml.

Maximum dose of iodinated radiocontrast dye

Method I *: 5 ml × body weight (kg)/serum creatinine (mg/dl) (not more than 300 ml) [refer to Cigarroa calculation formula]

Method II: 3.7 times creatinine clearance [according to 2011 ACCF/AHAUA/NSTEMI Treatment Guidelines]

For those with severe renal insufficiency, try to choose an imaging method that does not require iodine-based contrast agents or a non-imaging method that can provide sufficient diagnostic information.

Avoid repeated use of the diagnostic dose of an iodinated contrast medium in a short period of time. If repeated use is indeed necessary, it is recommended that the interval between two MRI contrast agent applications be ≥14 days.

Other precautions for the use of iodinated contrast agents

Preheating: Before using an iodinated contrast agent, it is recommended to heat the contrast agent to 37 °C and place it in a thermostat.

Hydration: It is recommended to hydrate patients within 6 to 12 hours before using an iodinated contrast agent to within 24 hours after use. Hydration method: Intra-arterial drug users are advised to receive intravenous rehydration and oral rehydration concomitantly, and oral rehydration is recommended for intravenous drug users.

Stay and observation: After the injection of the iodine-based contrast media, the patient needs to stay and be observed for 30 minutes before leaving the examination room.

Establish an emergency channel: Establish an emergency rapid support mechanism for the rescue of adverse reactions caused by iodinated contrast agents with the emergency room or other clinical related departments to ensure that after an adverse reaction occurs, clinicians can promptly rush to the rescue scene for rescue if necessary.

Prevention and Management of Vascular Extravasation of Iodinated Contrast Agents

Prevention

Choose appropriate blood vessels for venipuncture and operate carefully; when using a high-pressure syringe, choose a puncture needle and catheter that match the injection flow rate; properly fix the puncture needle; communicate with the patient and get cooperation. Another kind of contrast media, iopamidol injection, is also widely used.

Management

Mild extravasation: Most injuries are minor and need no treatment. However, the patient should be instructed to keep observing. If the extravasation worsens, the patient should seek medical attention in time. For individuals with significant pain, common cold and hydropathic compresses can be given locally.

Moderate and severe extravasation: ① raise the affected limb to promote blood return. ② Use 50% magnesium sulfate moisturizing cold compress in the beginning, and after 24-hours change to magnesium sulfate moisturizing hot compress, or use mucopolysaccharide ointment for topical application, or use 0.05% dexamethasone for local hydropathic compress. ③ Those with severe contrast agent extravasation should be given oral dexamethasone 5 mg/time tid for 3 consecutive days on the basis of topical drug use. ④ If necessary, consult a clinician for medication.

As one of the most professional contrast media companies, beijing beilu pharmaceutical co ltdprovides glimepiride and contrast dye, contrast agents used in ct, x ray contrast mediaand etc.Want to knowmore, contact us.



Send product request

To: Beijing Beilu Pharmaceutical Co., Ltd
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Glimepiride Tablets
Glimepiride Tablets Glimepiride 1 Tabletis a sulfonylurea hypoglycemic drug that can be used in combination with insulin. In 2001, glimepiride 2 tablet(Dibei), as the ...
Ferric Ammonium Citrate Effervescent Granules
Ferric Ammonium Citrate Effervescent Granules Ferric Ammonium Citrate Effervescent Granules was launched in 2004. It is an oral magnetic resonance contrast agent/media approved by NMPA in the m...
Gadopentetate Dimeglumine Injection/API
Gadopentetate Dimeglumine Injection/API Since Gadopentetate Dimeglumine Injection was launched in 1992 by Beilu Pharma in China, it was highly recommended and accepted by the radiologist,...
Ferric Ammonium Citrate Effervescent Granules
Ferric Ammonium Citrate Effervescent Granules Ferric AmmoniumCitrate Effervescent Granules was launched in 2004. It is an oral magnetic resonance contrast agent/media approved by NMPA in the ma...
Contrast Media
Contrast Media For the purpose of medical imaging, a certain substance is introduced into the human body to change the image contrast of local tissues of the body...
All supplier products

Same products

Togo cell freezing container KGSQ Liquid Nitrogen Field Tank
Togo cell freezing container KGSQ Liquid Nitrogen Field Tank Seller: Henan Tianzhidao Biological Technology Co., Ltd The use of liquid nitrogen tanks covers scientific research, animal husbandry, gourmet food, beau...
White Fiberglass Surface, Packaging Type: Roll at
White Fiberglass Surface, Packaging Type: Roll at Seller: Jiangsu Zeyusen Carbon Fiber Technology Co., Ltd. Fiberglass surface mat is mainly used in the surface layer of fiberglass merchandise, it has th...
Burundi liquid nitrogen container for cell storage KGSQ cryo dewar
Burundi liquid nitrogen container for cell storage KGSQ cryo dewar Seller: Henan Tianzhidao Biological Technology Co., Ltd. The use of liquid nitrogen tanks covers scientific research, animal husbandry, gourmet food, beau...
3x large magnifying glass with LED - evenly illuminates viewing area
3x large magnifying glass with LED - evenly illuminates viewing area Seller: PHONEFIX Technology Co., Ltd. RECTANGULAR SHAPES THE WAY YOU NATURALLY READ: The rectangular lens is especially design to sim...
NDT3055L 3055L SOT-223 car computer board Transistor
NDT3055L 3055L SOT-223 car computer board Transistor Seller: Shenzhen weikexiu technology Co.,Ltd The NDT3055L 3055L SOT-223 car computer board transistor is a critical component used in the repa...