11KV Auto Recloser Vacuum Circuit Breaker
ZW32 series 11 kv breakerare used in distribution systems. 11kv auto reclosers are used to make and break normal and fault currents. 11kv outdoor circuit breakerare fully equipped with sensors and a controller to provide a means of protection and control. In case of a line fault, breakers can break and make currents several times, thus avoiding longer network interruptions due to temporary faults.
The manufacture, design, and testing of the vcb 11kvbreaker by our electric power equipment ltd China is based on current standards IEC 62271-100. We can give you the most competitive11kv vacuum circuit breaker price.
11KV Auto Recloser Application
The 11 KV vacuum circuit breaker is equipped with one integrated current transformer per pole. The current transformer has a ratio of 600 A:5A.
VCB rating for 11kvRecloser is for protection purposes and optimized for operation with the controller.
11KV Auto Recloser Technical Parameters
|
Products Type |
ZW32-12 |
|
Maximum System Voltage |
12kV |
|
Rated Continuous Current |
630A |
|
Rated Frequency |
50/60Hz |
|
Short Time Withstand Current |
20kA/1sec |
|
Mainly Active Load Current |
630A |
|
Number of Load-break Operations |
30 |
|
Short-circuit Making Current (peak) |
50kA |
|
Number of Making Operations |
5 times |
|
Cable Charging Current |
25A |
|
Line Charging Current |
|
|
Closed Loop Circuit Current |
630A |
|
Transformer Magnetizing Current |
22A |
|
Wet Condition-10sec Ph- Ph-Eth, Across Interrupters |
45kV |
|
DryCondition-1min,Ph- Ph, Phase to Earth |
42kV |
|
Dry Condition - 1 min AcrossInterrupter |
48kV |
|
Phase to Phase, Phase to Earth |
75kV |
|
Across Interrupter |
85kV |
|
Internal Arc Test |
20kA /0.1 sec |
|
Arc Extinction Medium |
vacuum |
|
Insulation Medium |
vacuum |
|
Creepage Distance (Silicon) |
780mm |
|
Dry arcing distance |
≥200mm |
|
IP Level |
67 |
|
Closing/Opening Time |
<1sec |
|
Mechanical Operations (Guaranteed) |
10000times |
|
Operating Temperature (*Manual Type) |
-25~+70℃ |
Gopower is a professional electric power equipment company, we provide auto recloser, electrical control cabinet, outdoor vcband etc. For more information, please feel free to contact us!
Send product request
Other supplier products
| SF6 Gas Load Break Switch 11kv | The 11 kv load break switch is suitable for the distribution network with the highest voltage 11kV, the rated current 630A, and the rated frequency... | |
| 11KV Vacuum Circuit Breaker | 11KV Vacuum Circuit Breaker ZW32 series 11kv vacuum circuit breaker are used in distribution systems. 11kv auto reclosersare used to make and brea... | |
| Recloser Control Box-Feeder Terminal Unit | Recloser Control Box-Feeder Terminal Unit The feeder terminal unit(FTU) is a new HV switch control device of control cabinet enclosures equipped w... | |
| 11KV Recloser Vacuum Circuit Breaker | ZW32 seriesvcb rating for 11kvare used in distribution systems.11kv auto recloserisused to make and break normal and fault currents.11kv outdoor ci... | |
| Control Box-Feeder Terminal Unit | Control Box-Feeder Terminal Unit The feeder terminal unit(FTU) is a new HV switch control device of control cabinet enclosures equipped with both ... |
Same products
| Cold Glaze Stabilizer (Glazemate) | Seller: Marine Hydrocolloids | Meron’s Cold Glaze Stabilizer Glazemate, a ready to use Neutral Cold Glaze Stabiliser, whic... | |
| Pectin | Seller: Marine Hydrocolloids | Meron Pectin is a structural polysaccharide of the cell wall of plants, Commercial pectin is comm... | |
| Milk Shake Stabilizer | Seller: Marine Hydrocolloids | Meron’s Milk Shake StabilizerOur Milkshake Stabilizer has been designed to provide creamy m... | |
| Flavoured Milk Stabilizer | Seller: Marine Hydrocolloids | Meron’s Flavoured Milk StabilizerFlavoured milk drinks are sweetened dairy drinks, typicall... | |
| Ice Cream Stabilizer | Seller: Marine Hydrocolloids | Meron’s IceCream Stabilizer is a 100% vegan blend developed to not only enhance the texture... |