WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer
HANGZHOU ZETIAN TECHNOLOGY CO., LTDwas established in 2008, and as a fast-growing company specialized in environmental pollution monitoring and industrial process control, ZETIAN’s instruments and emission analyzers can provide you best solutions, including series ofwater quality testinginstrumentsand types of air quality monitors for sale.
Overview Of WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer Wastewater
WDet-5000 is a self-developed ammonia-nitrogen online monitoring analyzer wastewater, based on the global initiative magnetic conductivity measurement platform, combining with constant optical fiber and digestion colorimetric integration technology. The ammonia-nitrogen automatic online monitoring analyzer wastewater has the features, including high precision, low detection limit, high stability and low maintenance frequency.
This ammonia analyzer wastewaterworks in accordance with the technical requirements of HJ/T 536-2009 Water Quality Ammonia-Nitrogen Measurement-Salicylic Acid Method, fully meets the pollution sources, municipal wastewater, industrial processes in the application areas, and has passed the certification of CMC and CCEP.
Features Of WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer
High accuracy and reliability, strong capability of anti-interference
● Magnetic conductivity measurement technology used on the ammonia-nitrogen analyzer wastewater will be not affected by chromaticity, suspended solids, and bubbles, especially suitable for the monitoring of inlet water
● The ammonia-nitrogen analyzer wastewater has a special design of flow and reagent ratio, high precision, low detection limit(0.01mg/L)
● The ammonia-nitrogen analyzer wastewater adopts constant optical fiber and light intensity compensation algorithm, small drift for long-term operation
Low maintenance and cost
● The ammonia-nitrogen analyzer wastewater has a key self-check function, easy to debug, maintain, comparison test
● The ammonia-nitrogen analyzer wastewater has a self-diagnosis function, assisting maintainer to analyze the failure
● This type of water analyzer instrumentimportes single-channel high integration valve island which is simple and easy to maintain, dismantle and clean
● The ammonia-nitrogen analyzer wastewater has all-day networking for real-time inspection of instrument running state
High intelligent level
● Scan code function: rapidly obtain running/maintenance information of the the ammonia-nitrogen analyzer wastewater
● Alarm function: the ammonia-nitrogen analyzer wastewater provides intuitive and accurate information for grounding self-check, reagent insufficiency and etc
● Quality control: the ammonia-nitrogen analyzer wastewater is equipped with a parallel sample test, standard sample verification, and standard recovery rate detection
● Reverse control function: the ammonia-nitrogen analyzer wastewater starts automatically by flow and PH
Technical Specification Of WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer
Method |
ammoniacal nitrogen water qualityMeasurement-Salicylic Acid Method |
Range |
|
Zero Drift |
<0.02mg/L |
Span Drift |
<1% |
Indication Error |
±10% |
Repeatability |
≤3% |
Memory Effect |
20%F.S. ±0.3mg/L |
80% F.S. ±0.2mg/L |
|
Interval |
Hourly and interval measurement, and the instrument can also be started by serial port |
Maintenance |
<2 hour/month |
Quantitative Lower Limit |
|
Quality Control Sample Comparison |
±10% |
Water Sample Comparison |
>2mg/L±10% ≤2mg/L±0.2mg/L |
Reagent |
1 set reagents is able for about 250 times of measurement (can be customized according to field needs) |
External Interface |
1×4-20mA input/output (expandable to 2 ) RS485/RS232/USB interface/WIFI/ Bluetooth (optional) |
Working Temp |
5℃~40℃ |
Power |
200W (220VAC 50Hz), regardless of the pump |
Send product request
Other supplier products
EQMS-200 VOCs Online Monitoring System | Overview EQMS-200 VOCs online monitoring system adopts PID (photoionization detector ) for gas detection. The target gas is irradiated I bombarded ... | |
EM-5P Portable Flue Gas Analyzer | Overview Of EM-5P Portable Flue Gas Analyzer EM-5P portable flue gas analyzersystem mainly consists of gas monitoring sensors (SO2, NOx, CO, CO2), ... | |
Continuous Emission Monitoring & Process Control | What is the continuous emission monitoring system working principle? The instruments and analyzers produced by Zetian now are widely used at home a... | |
WDet-5000TPN Total Nitrogen Online Automatic Analyzer | HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008, and has national wide impact in China now as a fast-growing company specialized in env... | |
Continuous Emission Monitoring & Process Control | What is the continuous emission monitoring system working principle? The instruments and analyzers produced by Zetian now are widely used at home a... |
Same products
LEN503 Nebulizer | Seller: Lepu Medical Technology(Beijing)Co.,Ltd | Cute pet caring Small atomized particles nebulizer machine for kids Adjustable atomizing cup H... | |
SINOART Shanghai Co., Ltd. | Seller: SINOART Shanghai Co., Ltd. | SINOART Shanghai Co., Ltd. is a combined industrial & trading company in China, specializing ... | |
FPQ2W-10/3T20 10kV Pin Insulators | Seller: Guangdong Yufeng Industries Co.,Ltd | The crimping process of polymer pin type insulatorsshould pay attention to the crimping force, co... | |
Honduras liquid nitrogen tank for artificial insemination KGSQ Dewar flask | Seller: Henan Tianzhidao Biological Technology Co., Ltd | Livestock liquid nitrogen tanksare widely used in the breeding industry, especially in the freezi... | |
Burundi liquid nitrogen dewar semen tank KGSQ | Seller: Henan Tianzhidao Biological Technology Co., Ltd. | Livestock liquid nitrogen tanksare widely used in the breeding industry, especially in the freezi... |