DSH-L3/L3S Visible Spectrophotometer
-
DSH-L3/L3SseriesVisiblespectrophotometersmeetthedailyanalysistoawiderangeofscientificapplications.Instrumentusesadvancedandreasonableopticalsystem,lownoisecircuitdesign,withexcellentreliabilityandstability.
- Usestheadvancedoptical,mechanicalandelectricaldesign,withsuperiorperformanceandcostperformance.
- Adopts7inchescolortouchliquidcrystaldisplay,operationisflexibleandconvenient.
- Wholewavelengthscanning,scanningsubband,dynamicscanning,andGOTOlambda,linearregression,directreadingconcentration,peakdetectionandotheradvancedfeatures.
- Usingspecialthermalplotter,canprintthedata,withspectralscan,scanwavelength,drawingthecurveoflinearregression,etc.
- WithUSBinterface,onlinewithaPCdirectly,strengthenedtheinstrumenttestingdataprocessingfunctionssuchas,scanningmap,implementsthetestdocumentsofhugeamountsofstorage,alsofacilitatethesecondarydevelopmentfortheuser.
- Advancedelectricityprotectivemeasures,canmemorytestdata,scanningmap,reviseregressionequationetc.,realizedthefastbootinitializationentertheteststate.
- maintechnicalparameters
- Wavelengthrange:325nm~1100nm
- Wavelengthmaximumpermissibleerror:±0.5nm
- Wavelengthrepeatability:≤0.2nm
- SpectralBandwidth:2nm
- Straylight:≤0.05%(T)(at360nm,determineinNaNO2)
- Transmittancerange:0.0%(T)~200.0%(T)
- Absorbancerange:-0.301(A)~4.000(A)
- Transmittancemaximumpermissibleerror:±0.5%(T)(measuredinNBS930D)
- Drift:≤0.0009A/0.5h(bootafter2h,500nm)
- TransmittanceRepeatability:≤0.20%(T)
- Baselineflatness:±0.002A(335nm~1090nm)onlyappliestoSSeries
- Noise:100%(T)Noise≤0.2%(T)0%(T)Noise≤0.1%(T)
- Scanspeed:fast,mediumandslow
- Ambienttemperature:5℃~35℃
- Humidity:≤85%
- Optionalprinter,PCUVWin8Software
- Powersupply:AC220V±22V50Hz±1Hz
- RatedPower:120W
Send product request
Other supplier products
| ATEM-4 Transient Electromagnetic Water Detector | TransientElectromagneticMethod(TEM)isakindoftime-domainelectromagneticmethod,whichusesoreandundergroundwater’sconductivityandmagnetoconductiv... | |
| DSHD-0613 Asphalt Breaking Point Tester | Purpose: 1)DSHD-0613AsphaltBreakingPointTesterisdesignedanddevelopedasperT0613“AsphaltBreakingPointTest(FraassMethods)”intheIndustrySta... | |
| DSHY-501 Circulating Constant Temperature Water Bath | Productstandard: Theinstrumentisalaboratoryinstrumentspeciallydesignedandmadeforcorrespondingfactories,companies,constructionunits,researchinstitu... | |
| 4530F Atomic Absorption Spectrometer | TheproductiscompletelycontrolledbythePC,canflexiblymatchingflameandgraphitefurnaceatomizer.Theuniqueopticalandmechanicaldesign,safeandconvenientfla... | |
| DSHD-5096 Corrosion Tester | A:ProductIntroduction: DSHD-5096CorrosionTesterisdesignedaccordingthestandardsofGB/T11143,GB/T5096andSH/T0023.Itisamultipurposecorrosiontesterforpe... |