E-Stop Button, Safety Gate Safety Relay

CHENZHU e stop safety relayare suitable for the application of emergency Stop button and safety gate. Support 2 safety output contacts (N/O) and 2 auxiliary output contacts (N/C) or 3NO+1NC or 2NO+2NC or 2NO+1NC+3NO(t)+1NC(t).

Safety monitoring relays can be operated in single or double channel mode, manual or automatic reset, and with the function of monitoring the short circuit between channels.

Features & Advantages of E-Stop Button, Safety Gate Safety Emergency Stop Relay

Support single or dual-channel

Support instantaneous or delayed output

Support manual or automatic reset

Short circuit monitoring

Parameter of ChenzhuE-Stop Button, Safety Gate Safety Relay

CZSR8001-3A1B

CZSR8001-3A1B(M)

CZSR8002-2A2AT

CZSR8002-2A2AT(M)

CZSR8003-3A1B

CZSR8001-2A1B

CZSR8001-2A1B3AT1BT

Supply voltage

24V DC/AC

24V DC/AC

24V DC

24V DC

100V~230V AC

24V DC/AC

24V DC/AC

Voltage tolerance

Current consumption

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤130mA (24V DC)

≤130mA (24V DC)

≤7 VA (220V AC)

≤90mA (24V DC) / ≤240mA (24V DC)

≤170mA (24V DC) / ≤400mA (24V AC)

Input current

≤50mA (24V DC)

≤50mA (24V DC)

≤50mA (24V DC)

≤50mA (24V DC)

≤50mA (220V AC)

≤50mA (24V DC)

≤50mA (24V DC)

Cable resistance

≤15Ω

≤15Ω

≤15Ω

≤15Ω

≤15Ω

≤15Ω

≤15Ω

Input devices

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

Number of contacts

3NO+1NC

3NO+1NC

2NO+2NO(t)

2NO+2NO(t)

3NO+1NC

2NO+2NC

2NO+1NC+3NO(t)+1NC(t)

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2

AgSnO2

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 μm Au

AgSnO2 + 0.2 μm Au

External contact fuse protection

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO)

10A gL/gG NEOZED (NO)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C)

10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C)

Mechanical endurance of contacts

≥107

≥107

≥107

≥107

≥107

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V

In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

Switch-on delay

≤300ms

≤150ms

≤300ms

≤150ms

≤300ms

≤300ms

≤300ms

Delay-on de-energisation

≤30ms

≤30ms

≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s)

≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s)

≤30ms

≤30ms (instantaneous);-

≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(delayed, factory set as 5s)

Recovery time

≤100ms

≤100ms

≤100ms

≤100ms

≤500ms

≤100ms

≤100ms

Supply short interruption

20ms

20ms

20ms

20ms

20ms

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

10%~90%

10%~90%

10%~90%

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

≤2000m

≤2000m

≤2000m

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

2

2

2

2

2

Rated insulation voltage

250V AC

250V AC

250V AC

250V AC

250V AC

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

4000V (1.2/50us)

4000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

SIL3

SIL3

SIL3

SIL3

SIL3

Performance level

PLe

PLe

PLe

PLe

PLe

PLe

PLe

Category

If you want to know more kinds of safety automation system, please visit our website.



Send product request

To: Shanghai Chenzhu Instrument Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

GS8500-EX Series Intrinsic Safety Barrier
GS8500-EX Series Intrinsic Safety Barrier GS8500-EX range functional safety isolated barriers are CHENZHU's hit products, which obtained the first IECEx, ATEX, DE TUV SIL, JP TIIS certifica...
The Principle and Classification of Safety Barriers
The Principle and Classification of Safety Barriers China safety barrier is generally used in intrinsic safety systems. Intrinsic safety refers to system explosion-proof technology, which refers to t...
CZ2000 Series Signal Conditioner
CZ2000 Series Signal Conditioner CZ2000 analog signal isolator, analog voltage isolator CZ2000 range voltage signal conditioneruse high-efficiency electromagnetic isolation techno...
AC Power SPD
AC Power SPD The power surge protector for power surge ac unitis designed to prevent transient surge conditions. Large single surge events, such as lightning, c...
Antennas And Feeders SPD
Antennas And Feeders SPD Antennas feeders SPD, the coaxial lightning surge protectoror coax surge suppressor, is used in the antenna feeder circuit of the radio communicati...
All supplier products

Same products

Tubular Conveyor Belt
Tubular Conveyor Belt Seller: Qingdao Rentone Belt Co., Ltd. The tubular belt conveyor, also known as the pipe conveyor belt, is a type of conveyor belt that ...
Steep Angle Sidewall Conveyor Belt
Steep Angle Sidewall Conveyor Belt Seller: Qingdao Rentone Belt Co., Ltd. The steep incline conveyor beltis manufactured through secondary vulcanizing process. It is speci...
Steel Cord Conveyor Belt
Steel Cord Conveyor Belt Seller: Qingdao Rentone Belt Co., Ltd. Rentone Belt is one of the most renowned china steel cord conveyor belt manufacturers in China. W...
Special Conveyor Belt
Special Conveyor Belt Seller: Qingdao Rentone Belt Co., Ltd. As a professional special conveyor beltmanufacturer, Rentone Belt has the capability to manufactu...
Solid Woven Conveyor Belt
Solid Woven Conveyor Belt Seller: Qingdao Rentone Belt Co., Ltd. As a reliable solid woven belt manufacturer, Rentone Belt Co., Ltd. is dedicated to serving our c...