.

Safety Relay

Safety Relay

Automation direct safety monitering relays are mainly applied to the safety control circuit, connecting the safety sensing elements and mechanical equipment motion controller. The working principle of safety relay interlock system: when there is a fault in the safety circuit, the intrinsic safe relayautomatically detects the fault and stops the machine movement, to protect equipment and personnel safety.

Chenzhu solid state safety rated relay is the first product to get PLe/Cat.4, SIL3 certified in China mainland. Automation and safety is the main character of the programmable safety relay module that you can be assured.

Various safety relay products are available for you to select. We have safety relay for E-stop buttons, emergency stop buttons, two-hand control buttons. We also provide light curtain safety relay, sil 2 rated relay and sil 3 rated relays to better meet the needs of our customers. For more information, please feel free to contact us.

Safety Relay Types

CZSR Classic Series Safety Relay

E-Stop Button, Safety Gate Safety Relay

Light Curtain Safety Relay

Two-hand Push Buttons Safety Relay

Safety Mat Safety Relay

Extension Module Safetu Relay

CZSR Process Series Safety Relay

DO Signal (SIS) 24V DC 2A Safety Relay

DO Signal (SIS) 24V DC 3A Safety Relay

DO Signal (SIS) Input 24V DC 5A Safety Relay

CZSR Smart Series Safety Relay

FAQ of Safety Relay

Q

What is safety relay?

A

Safety relay offer an extra level of protection usually through a redundant wiring system.

These relays are used to enable an monitor the signals between other safety devices such as safety switched sensors, light curtains, intrinsic safety barriers and isolators. In many cases, the safety relay can be paired with a safety PLC configurable safety relay or safety controller.

Q

What is the difference between safety relay and normal relay?

A

Compared to a normal relay, a safety control relay have mandatory steering contact arrangement assures protection when contact fusion happens. A safety relay is a module composed of multiple relays and logic circuits. It is a circuit composition unit. In order to achieve the correct and low malfunction feature and to minimize errors and failure values, and complete each other's faults in a fault state to enhance safety factors.

Q

How does an intrinsically safe barrier work?

A

Safety relays are generally composed of two or more relays and electronic circuits, so as to complement each other's abnormal defects. Even if any component fails, it can diagnose the failure and enter a safe state. And it will not affect the shutdown instructions issued to the machine, ensuring the safety of production. From the structural point of view, the safety relay generally adopts a dual-channel structure, and the channels can diagnose each other, and use a forced-oriented relay to realize the diagnosis of the output contact fusion fault.

Q

How do safety relays improve safety?

A

Like electrical panel box surge protector, safety relays are devices that implement safety functions. When a danger occurs, the safety relay will play a role in reducing the danger to an acceptable level. When an error occurs, the safety relay will initiate a safe and reliable response. Each safety relay monitors a specific function.

Q

What are the main applications of safety relays?

A

Suitable for the application of electromagnetic door lock switch to ensure the safety of the work area.

It is suitable for the key to cooperate with the safety gate switch to detect the opening and closing of the door.

Applicable to safety gates, detecting the position of the door, opening or closing applications.

Suitable for light beam devices to prevent workers from entering the dangerous work area.

Applicable safety mat switch to confirm that workers can safely enter the hazardous work area.

Applicable E-stop buttons, in case of emergency, stop the machine operation.

Q

What's the line monitoring function of Safety Relay?

A

Line monitoring is the basic function for safety relay which is used into SIS, which all CHENZHU automation direct safety relayofferred and built to PCB. Just input the DO signal and safety relay will check the test pulse automatically. When pulse error happens, safety relay will cut off the output so that to ensure SIF to work.

CHENZHU manufactures the most reliable interface product for safety automation system. We are here to help your device run more safely. Here you can not only get world-class products, but also outstanding service for safety and automation system.



Send product request

To: Shanghai Chenzhu Instrument Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

DC Power SPD
DC Power SPD Like all outdoor buildings, photovoltaic devices are vulnerable to lightning strikes. By far the biggest culprit for the power surges that damage s...
A Brief Introduction of Intrinsically Safe Barrier
A Brief Introduction of Intrinsically Safe Barrier Intrinsically safety barriers in instrumentationimproves workplace safety by limiting the energy available in the process. Ⅰ. What is intrinsica...
CZ2000 Series Signal Conditioner
CZ2000 Series Signal Conditioner CZ2000 range signal conditioners use high-efficiency electromagnetic isolation technology to achieve reliable galvanic isolation among power supply...
Intrinsic Isolated Barrier
Intrinsic Isolated Barrier What Is Isolation Barrier? Intrinsic safety barriers and isolators use intrinsically safe explosion-proof and functional safety technologies and a...
Antennas And Feeders SPD
Antennas And Feeders SPD Antennas And Feeders SPD Antennas feeders SPD, the coax lightning protectoror coax surge suppressor, is used in the antenna feeder circuit of the ...
All supplier products

Same products

CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V SMD LF
CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V SMD LF Seller: ZK Electronic Technology Co. Part name:EEF-CX0J101R Description:CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V ...
Heavy Copper PCB Manufacturer
Heavy Copper PCB Manufacturer Seller: Xinfeng Huihe Circuits Co., Ltd. Heavy Copper PCB, pcb fabrication up to 12oz, large current, pcb circuitfabrication base material...
8 Layer ENIG Half Hole Custom PCB
8 Layer ENIG Half Hole Custom PCB Seller: Xinfeng Huihe Circuits Co., Ltd. Number of layers: 8 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 4/3mil Inner lay...
4 Layer ENIG Impedance Control Half Hole PCB Electric Circuit Board
4 Layer ENIG Impedance Control Half Hole PCB Electric Circuit Board Seller: Xinfeng Huihe Circuits Co., Ltd. Number of layers: 4 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 6/4mil Inner lay...
4 Layer ENIG Impedance Control Half Hole Fr4 PCB
4 Layer ENIG Impedance Control Half Hole Fr4 PCB Seller: Xinfeng Huihe Circuits Co., Ltd. Number of layers: 4 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 6/3.5mil Inner l...