Bettersizer 2600

Laser Particle Size Instrument(Dry & Wet Dispersions)

The Bettersizer 2600 utilizes this laser diffraction technology. There are 92 photoelectric detectors to convert light signals from the scattering spectrum to electrical signals, which are transmitted into an intelligent software. By implementing the Mie scattering theory to the data and performing mathematical conversion, the complete particle size distribution can be derived.

Measurement: Particle size

Particle size range:

Wet dispersion: 0.02 to 2600μm

Dry dispersion: 0.1 to 2600μm

Dispersion type: Wet and Dry

Technology: Laser diffraction

Precise measurement of both large and small particles covering the broadest range by a new patented technology utilizing both Fourier and Reverse Fourier optical systems

Optical bench with 92 detectors covering an angular range of 0.016° - 165°

Optional wet and/or dry dispersion

Small volume dry dispersing module for small sample quantities especially for pharmaceutical or valuable samples in short supply

Easy and fast to changeover between dispersing modules

Easy to implement, create and use Standard Operation Procedures for new materials

Automatic alignment of the optical system

User-friendly software, easily learnt

Download Brochure Request Demo

The Fundamentals of Bettersizer 2600

Sample Dispersion ModulesBT-802Wet Small VolumeBT-80N

BT-902BT-903

Sample DispersionWet sample dispersionWet small volume sample dispersionAnti-corrosive sample dispersion

Dry sample dispersionDry small volume sample dispersion

Dispersion Modules

Combine with Main Device

BT-903 Combine with Main Device

Volume600mL (dispersion medium)8 mL (dispersion medium)80 mL (dispersion medium)

  1. 0.02 - 1 g (sample)

AutomationFull-automatedSemi-automatedSemi-automated

Full automatedFull automated

Application Notes

Application of Laser Particle Size Analyzer in Pigments

21 Jun 2021

Particle Size and Shape Analysis of Powder Coatings

01 Jun 2021

Particle Size Analyzing of Chocolate by Laser Diffraction

04 Jun 2021

Investigating the Relation Between Coffee Extraction and Ground Coffee Size

08 Jun 2021

FeaturesSOPPerformanceTechnologySpecificationInquiryAccessory

1)FOURIER AND REVERSE FOURIER OPTICAL SYSTEM

The Bettersizer 2600 is superior in the combination of Fourier and inverse Fourier design. This smart design allows, on the one hand, the detection of stray light in a very wide angular range from 0.016° to 165°. On the other hand, in contrast to the inverse Fourier design, the particles do not have to lie on one plane – the simultaneously accurate measurement of small and large particles is therefore achieved.

Features of combination of Fourier and inverse Fourier design

Spherical detector array: Forward, lateral and backward detectors in 92 pieces in total;

Super large Fourier lens;

Small footprint: Compact design to save space

2)INTUITIVE AND POWERFUL SOFTWARE

Intuitive operation and orderly user interface

Real-time mode for determining the optimal measurement conditions

Fully automatic measurement routine

Automatic cleaning routine

Automatic data backup and highly customizable reports

Direct conversion according to Fraunhofer and Mie evaluation models

Switch between wet and dry dispersion modules with one click

3)WET DISPERSION

BT-802 is designed for particle size measurement with water as the medium.

BT-802 is made up of ABS shell. The components of it include centrifugal pump, peristaltic pump, ultrasonic disperser, pinch valve, control circuit, etc. The stirring speed is adjustable from 500 - 2500 rpm. Built-in ultrasonic system (50 W) ensures stable dispersion of samples.

BT-80N is designed for particle size measurements with organic solvents as the media. BT-80N is suitable for common organic solvents, for example:

EthanolMethanolIsopropanolEther

TolueneXyleneDichloromethaneOctane

Ethyl acetateAcetoneMethyl oleateNMP solvents

BT-80N is made up of stainlesssteel shell. The components of it include centrifugal pump, ultrasonic disperser, PTFE pipeline, sintered-quartz sample cell, control circuit, etc.

Wet Small Volume Dispersion Module is designed for valuable or small-volume sample measurements, where the medium is solvent or water. The module consists of ABS shell, stirring motor, cuvette (8 ml), stirrer, etc.

Maximum volume in 8 mL with samples mass in 0.005 - 0.1 g.

Suitable for samples dispersed in water or organic phase.

4)DRY DISPERSION

BT-902 is suitable for dry powders particle size measurements. The gas used can be compressed air, nitrogen or other noble gases.

BT-902 is made up of electromagnetic vibration feeder, venturi pipe, gas circuit, electric circuit, pressure sensor, etc.

BT-903 is designed for particle size measurements of valuable and small amount dry powders with a minimum samples volume of 20 mg.

BT-903 is composed of venturi pipe, gas circuit, electric circuit, samples tube, etc.

5)Application

Related Powder Characteristics Tester

Bettersizer S3 Plus

2 to 3500μm(Image System)

Bettersizer ST

Particle size: 0.1 to 1000µm

Nanoptic 90 Plus

Particle size: 0.4nm to 9μm

BT-Online1

Particle size: 0.1 to 1000µm

If you want to know more about particle sizer price, please contact us.



Send product request

To: Dandong Bettersize Instruments Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

BT-Online1
BT-Online1 Online Particle Size Analyzer BT-Online1 online particle size analysisis an on-line particle size monitoring system for real-time particle size mo...
BeDensi B1
BeDensi B1 Bulk Density Tester BeDensi B1 bulk density testing equipment adopts natural deposition method. Its manufacturing standard meets the criterion of G...
Bettersizer ST
Bettersizer ST The Bettersizer ST is an automated laser scattering particle size distribution analyzerdesigned for industrial quality control. Its patented DLOS (...
HFlow 1
HFlow 1 We are Bettersize,a professional particle size analyzer instrumentsupplier, providing particle size measurement units, andpowder flowbility tester...
Laser Diffraction
Laser Diffraction Particle size measurement using static light scattering (Particle size determination by laser diffraction) The particle size distribution as a par...
All supplier products

Same products

LM-79 Moving Detector Goniophotometer (Mirror Type C)
LM-79 Moving Detector Goniophotometer (Mirror Type C) Seller: LISUN ELECTRONICS (SHANGHAI) CO.,LTD Measurement:Luminous Intensity Data, Photometric Data, Luminous Intensity Distribution, Zonal Lum...
HB Series
HB Series Seller: Shanghai Kinglos Musical Instruments Co., Ltd. Personalized Violin Violin with carving flower, your personalized violin. Top: spruce. Back/Side...
Beginner Violin
Beginner Violin Seller: Shanghai Kinglos Musical Instruments Co., Ltd. Good Beginner Violin Face material: Solid Spruce Back / Side: Maple Fingerboard material: ...
Advance Series
Advance Series Seller: Shanghai Kinglos Musical Instruments Co., Ltd. Professional Violin Professional performance violin with high cost performance. Maple texture...
Acoustic Violin
Acoustic Violin Seller: Shanghai Kinglos Musical Instruments Co., Ltd. The semi acoustic violinproduced by kinglos have good quality, many varieties and complete specif...