.

Indoor Escalator

With incorporation of the well-developed escalator and moving walk technology,Website:, advanced micro-computer control system, high strength truss structure, classical driving system ,and completed safety devices,GRE series of escalators and moving walks fully ensure our products safe, reliable, endurable and bring steady and comfortable riding. Refine craftwork, fluent lines and elegant style form the combination of practical riding function and visual enjoyment. Frequency conversion technology selected makes products more energy-saving. Besides, outdoor escalator and moving walks can be fit for different kinds of environment and weather condition. Complying with national standard GB16899 and European standard EN115, the escalator and moving walk are applicable for heavy-passenger-flow location such as market, supermarket, hotel, subway, airport, train station, crossroad and public buildings.Safety devicesStatic electricity protection of stepEliminate static electricity raised from running of the steps.StandardStatic electricity protection of handrailEliminate static electricity raised from running of the handrail.StandardEmergency stop button on entrancePush the emergency stop button to stop the escalator (moving walk) against emergency raise.StandardHandrail entry safety protectionProtection against risk of other objects being jammed into handrail entry.StandardOver speed protectionProtection against risk of speed being over 20% of rated speed.StandardUnder speed protectionProtection against risk of speed being less than 20% of rated speed.StandardUnintentional reversal protectionProtection against risk of unintentional reversal of the direction of travel.StandardPhase failure protectionProtection against risk of phase failure.StandardShort circuit protectionProtection against risk of short circuit.StandardOver-load protectionProtection against risk of motor continually over load.StandardStep sagging protectionProtection against risk of steps being breakage and sagging.StandardStep sagging protectionProtection against risk of step chain being breakage of undue elongationStandardStep chains safety protectionProtection against risk of step chains being breakage of undue elongation.StandardComb safety guardProtection against risk of foreign objects being trapped at the point where the step enters the comb.StandardInspection socketTo provide voltage to inspect or maintain.StandardMachine room guardOne safety plate separates machine room from movable parts such as step to protect service personnel.StandardEmergency stop button on control cabinetPush the emergency stop button to stop the escalator (moving walk) against emergency raise when inspection and maintaining.StandardHandrail speed-detection protectionWhen handrail speed is 15% lower than the step speed, it stops in 15 seconds.StandardBrake over-distance protectionWhen step brake distance is 1.2 times larger than the stipulated distance, it prevents it from start again.StandardSkirting guardProtection against risk of foreign objects being jammed into clearance between steps and skirting.StandardFloor anti-start protectionIt stops when the floor plate is removed or opened.StandardMain drive chains safety protectionProtection against risk of drive chains being breakage or undue elongation.StandardSkirting brushBrushes on skirting to enhance the passenger's safety.StandardHost brake detectionWhen it detects the release condition of the host brake, it prevents it from start before its releaseStandardAnti-crawl deviceIt prevents the passengers from crawling to external handrailOptionalAnti-skid deviceIt installs outer cover plate which is closed to handrail height. It prevents the passengers from accidental crawl, skid,fall.OptionalArresterIt prevents the passengers from entering into the area between wall and handrail, between two escalators(moving walks)OptionalProtection baffleProtection baffle is set in the crossing of outer handrail edge and any obstacle.OptionalAuxiliary brakeAuxiliary brake will act and stop the escalator (moving walk) in case of main drive chains breakage or the steps or handrail changing from present direction of motion.OptionalGRE20 Standard configurationApplicationIndoor. 16-hr operation dailyH(m)≤6 m≤10mInclination (°)3530Step width (mm)600/800/1000Horizontal steps2/22/2 or 3/3Speed(m/s)0.5Main power380V/50Hz/3PBalustradeTempered glass(10mm)Handrail bracketStainless steelHandrailBlackBalustrade height (mm)900Inner & outer deckingHairline St.St.SkirtingHairline St.St.StepStainless steelLanding plateStainless steel (anti-sliding)illuminationlighting under upper & lower landing stepsIndicatorFailure code indicator on control cabinetOperationEmergency stop button / Key switch / Inspection operationGRE30 Standard configurationApplicationIndoor. 16-hr operation dailyH(m)≤16Inclination (°)30Step width (mm)1000Horizontal steps3/3Speed(m/s)0.5Main power380V/50Hz/3PBalustradeTempered glass(10mm)Handrail bracketStainless steelHandrailBlackBalustrade height (mm)900Inner & outer deckingHairline St.St.SkirtingWear resistant coating steel sheetStepStainless steelLanding plateStainless steel (anti-sliding)illuminationlighting under upper & lower landing stepsIndicatorFailure code indicator on control cabinetOperationEmergency stop button / Key switch / Inspection operationOptional configurationHandrailGreen, red, blue, yellowBalustrade height1000mmilluminationSkirting lightingComb lightingHandrail lightingIndicatorIndicator on outer deckingDirection indicatorRunning direction indicator on outer deckingStep or palletsOne-piece aluminumLanding plateAluminum alloy (anti-sliding)Energy controlVVVFExternal claddingHairline st.st./painted steel/glass/mirror st.st.Heating deviceTo heat the escalator ladder roadSpeed0.65m/s Only for GRE30/GRE50


Send product request

To: Sicher Elevator Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Machine Roomless Observation Elevator
Machine Roomless Observation Elevator Model:GRON20We adopt the multiple leading high and new environmental protection technology for GRON series machine roomless observation elevator. T...
Machine Room Passenger Elevator
Machine Room Passenger Elevator Model: GRPN20We know very well about the loss reduction and energy-saving,Website:, environmental protection ideas for GRPN20 machine roomless pass...
Traction Home Elevator
Traction Home Elevator Model:GRV20-IISRH Home elevator can operate under regular voltage. It doesn’t need special voltage support. It fulfills popularization of home elev...
Traction Freight Elevator
Traction Freight Elevator Model:GRFGRF Series freight elevators employing the fully PC controlling technology,Website:, AC variable frequency and variable voltage VVVF, has ...
Machine Room Observation Elevator
Machine Room Observation Elevator Model: GROS20We introduce a full set of the latest German control technology and apply new modern materials and the latest processing craft& techni...
All supplier products

Same products

Aluminum Perforated Ceiling Panel
Aluminum Perforated Ceiling Panel Seller: FOSHAN KEENHAI METAL PRODUCTS CO., LIMITED Aluminum Perforated Ceiling Panel
slewing bearing
slewing bearing Seller: Henan Zengkun Machinery Equipment Co.,ltd. Precision Four Point Contact Ball Slewing Bearing With External Gear SDQ-816 Precision Four Poin...
Busbar For EV/HEV Automobile Capacitor
Busbar For EV/HEV Automobile Capacitor Seller: Xiamen Galaxy Precision Technology Co., Ltd The electrical bus bar is available in rectangular, cross-sectional, round and many other shapes....
Flexible Bearing For Harmonic Reducer
Flexible Bearing For Harmonic Reducer Seller: Henan Zengkun Machinery Equipment Co.,ltd. Flexible Bearing For Harmonic Reducer Harmonic Reducer Bearing Transfer Motion And Power By Me...
Robot Reducer Bearing For RV E And RV C Type Reducer
Robot Reducer Bearing For RV E And RV C Type Reducer Seller: Henan Zengkun Machinery Equipment Co.,ltd. At Present, There Are Two Kinds Of Reducers Used In The Field Of Robots, One Is RV Reducer, The O...