ELECTRODEIONIZATION (EDI)

EDI is a pure water manufacturing technology that combines ion exchange technology, ion exchange membrane technology and ion electromigration technology. It skillfully combines electrodialysis and ion exchange technology, uses high voltage of electrodes at both ends to move charged ions in water, and cooperates with ion exchange resin and selective resin membrane to accelerate the removal of ions, so as to achieve the purpose of water purification. During EDI desalination, ions are removed by ion exchange membrane under the action of electric field. At the same time, water molecules generate hydrogen ions and hydroxide ions under the action of electric field, which continuously regenerate the ion exchange resin to keep the ion exchange resin in the best state.

Technical Data of Electrodeionization Unit, Electrodeionization System

Item

Reference value

Nominal Recovery:

90–95%

EDI Water Quality:

15–18 MΩ.CM(25℃)

FEED CONDUCTIVITY (INCLUDING CO2):

< 10 µs/cm(25℃)

Operating Temperature:

50–100° F

Maximum Inlet Pressure:

100 psig

Minimum Inlet Pressure:

60 psig

Expected Pressure Drop:

30–40 psig

Electrical Requirement:

380 VAC, 3-phase, 50 Hz.

OPERATING PRINCIPLES OF ELECTRODEIONIZATIO

EDI desalination process is to exchange ions in water with hydroxide ions or hydrogen ions in ion exchange resin, and then migrate these ions into concentrated water;

The above exchange reaction takes place in the freshwater chamber of the module. In the freshwater chamber, the hydroxide ion in the anion exchange resin exchanges with the anion in the water, and the hydrogen ion in the cation exchange resin exchanges with the cation in the water;

The exchanged ions migrate along the surface of the resin ball under the effect of the DC electric field and enter the concentrated water chamber through the ion exchange membrane;

The negatively charged anions are attracted by the anode, and these ions enter the adjacent concentrated water chamber through the anion membrane, while the adjacent cation membrane membrane does not allow them to pass through. These ions are blocked in the concentrated water, while the positively charged cations are attracted by the anion anion, and these ions enter the adjacent concentrated water chamber through the cation membrane, while the adjacent anion membrane does not allow them to pass through. These ions are blocked in the concentrated water.

In concentrated water, ions from both directions maintain electric neutrality. At the same time, the amount of current is proportional to the amount of ion migration. The amount of current consists of two parts, one part from the migration of removed ions, and the other part from the migration of water itself ionized into H+and OH - ions;

When the water flow passes through the fresh water chamber and the concentrated water chamber, the ions gradually enter the adjacent concentrated water chamber from the fresh water chamber and are carried out of the EDI module by the concentrated water;

Under the action of higher voltage gradient, water will generate a large amount of H+and OH- through electrolysis. These generated H+and OH- will continuously regenerate the ion exchange resin. Therefore, the ion exchange resin in EDI module does not need chemical regeneration;

The above is the desalination process of EDI.

Now the price of EDI water purification systemis reasonable, if you have needs to buy electrodeionization EDI system, please contact us.

Pharmaceutical purified water systems adopt the latest processes such as reverse osmosis and EDI. Purified water system pharmaceuticaldesigns a complete set of purified water process in a targeted manner. The quality of purified water for pharmaceutical manufacturing meets the requirements of the current USP, EP, JP and ChP for purified water.



Send product request

To: Nanjing Biocell Environmental Technology Co., Ltd
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

PW/WFI SKID
PW/WFI SKID PW/WFI SKID The purified water/water for injection(WFI) combined distribution system is a kind of equipment integration device, which can fully co...
WFI TANK/SKID
WFI TANK/SKID The distribution system is the core unit of the whole pharmaceutical water system, and its main function is to ensure that the pressure, flow and t...
CLEAN STEAM GENERATOR
CLEAN STEAM GENERATOR The prototype of the clean steam generatoris a pure steam generator in the pharmaceutical industry. In structural design, it simplifies and weakens...
PURE STEAM GENERATOR
PURE STEAM GENERATOR A pure steam generator is one of the important equipment used for tank equipment, pipeline system, and filter disinfection, and pure steam generato...
Purified Water System(PW)
Purified Water System(PW) System adopts the latest processes such as reverse osmosis and EDI. A complete set of purified water treatment process has been designed in a targe...
All supplier products

Same products

Methyl-3-Methoxy-2-(2-Chloromethylphenyl)-2-Propenoate
Methyl-3-Methoxy-2-(2-Chloromethylphenyl)-2-Propenoate Seller: Jostrong Tianjin Technology Co Ltd Cas No: Purity: 99% Molecular formula: C12H13CIO3 Molecular weight: 241 Application: Pharmac...
6-Ethyl-5-Fluoro-4-Hydroxy Pyrimidine
6-Ethyl-5-Fluoro-4-Hydroxy Pyrimidine Seller: Jostrong Tianjin Technology Co Ltd Cas No: Purity: 99% Appearance: White to off-white powder Molecular formula: C6H7FN2O Molecu...
4-Chloro-6-Ethyl-5-Fluoro Pyrimidine
4-Chloro-6-Ethyl-5-Fluoro Pyrimidine Seller: Jostrong Tianjin Technology Co Ltd Cas No: Purity: 99% Appearance: Colorless to light yellow liquid Molecular formula: C6H6CIFN2...
2-Methyl-4-(Trifluoromethyl) Thiazole-5-Carboxylic Acid
2-Methyl-4-(Trifluoromethyl) Thiazole-5-Carboxylic Acid Seller: Jostrong Tianjin Technology Co Ltd Cas No: Purity: 96% Appearance: White to off-white powder Molecular formula: C6H4F3NO2S Mole...
2-Hydroxy-6-(Trifluoromethyl) Pyridine
2-Hydroxy-6-(Trifluoromethyl) Pyridine Seller: Jostrong Tianjin Technology Co Ltd Cas: 34486-06-1 Purity: 99% Appearance: Greyish-white powder Molecular formula: C6H4F3NO Mole...