N+1 Redundant Power Supply TC-950RVN3

(AC to DC)

Safety Approval

Meet CE Rohs 2.0 2011/65/EU

Meet REACH

Operation Temp.: 0°C~45°C

Description:

VOLTAGE: 100 - 240Vac Full Range

FREQUENCY: 50 - 60Hz.

INPUT CURRENT: 17A for 115V AC, 7A for 230VAC.

INRUSH CURRENT: 60A for 115VAC, 120A for 230VAC

L x W x H: 300 x 101 x 125 (mm) / 11.81 x 3.98 x 4.92 (inches)

FEATURES:

  1. Redundant Power Supply
  2. Hot-swappable/Hot-pluggable, High-Density Redundant power supply
  3. Full Range AC Input.
  4. Efficiency:76% Typical at full load
  5. Hold-Up Time: 16ms at maximum load & normal input voltage.
  6. OVER VOLTAGE PROTECTION.
  7. SHORT CIRCUIT PROTECTION.
  8. OVER POWER PROTECTION.
  9. ENVIRONMENT TEMPERATURE

Operation Temperature: 0℃to +45℃

Cooling: BY BALL BEARING DC FAN.

Storage Temperature:-20℃ to 70℃

Humidity: 5% to 95%, non-condensing

  1. RELIABILITY

Mean Time Between Failure(MTBF)

Using MIL - HDBK -217F the calculated MTBF>100,000 hours at 25℃.



Send product request

To: Sure Star Computer Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

4U Redundant Power Supply  SS-300R8P
4U Redundant Power Supply SS-300R8P (AC to DC) Safety Approval Meet CE Rohs 2.0 2011/65/EU Meet REACH Operation Temp.: 0°C~40°C Description: VOLTAGE: 100 - 240Vac Full Range ...
Single Power Supply PS II - TCPS1D41Y040
Single Power Supply PS II - TCPS1D41Y040 (AC to DC) Safety Approval Meet CE Rohs 2.0 2011/65/EU Meet REACH Operation Temp.: 0°C~50°C High Efficiency Description: Voltage: 100 - 24...
N+1 Redundant Power Supply  TC-950RVN3
N+1 Redundant Power Supply TC-950RVN3 (AC to DC) Safety Approval Meet CE Rohs 2.0 2011/65/EU Meet REACH Operation Temp.: 0°C~45°C Description: VOLTAGE: 100 - 240Vac Full Range ...
1U Redundant Power Supply  R1J-250I1H2A0
1U Redundant Power Supply R1J-250I1H2A0 (AC to DC) Safety Approval Meet CE Rohs 2.0 2011/65/EU Meet REACH Operation Temp.: 0°C~45°C High Efficiency Low Noise Description: VOLTAGE...
Power On Delay Board  SS-DB5
Power On Delay Board SS-DB5 The Delay Board is designed to delay relay switching for applications server system or Motherboard on delays. If uesd properly. it will eliminate t...
All supplier products

Same products

Recloser Control Box-Feeder Terminal Unit
Recloser Control Box-Feeder Terminal Unit Seller: Zhuhai Gopower Smart Grid Co; LTD Recloser Control Box-Feeder Terminal Unit The feeder terminal unit(FTU) is a new HV switch contr...
Centralized Type DTU
Centralized Type DTU Seller: Zhuhai Gopower Smart Grid Co; LTD Centralized Type DTU The centralized DTU adopts high-performance MCU processor, high-speed indus...
33KV SF6 Gas Load Break Switch
33KV SF6 Gas Load Break Switch Seller: Zhuhai Gopower Smart Grid Co; LTD 33KV SF6 Gas Load Break Switch These load break switch 33kvare intended for outdoor applications...
24KV Recloser Vacuum Circuit Breaker24KV Recloser Vacuum Circuit Breaker
24KV Recloser Vacuum Circuit Breaker24KV Recloser Vacuum Circuit Breaker Seller: Zhuhai Gopower Smart Grid Co; LTD 24KV Recloser Vacuum Circuit Breaker The 24KV breaker switch unit is comprised of three poles, t...
LBS 24KV 630a SF6 Gas Load Break Switch
LBS 24KV 630a SF6 Gas Load Break Switch Seller: Zhuhai Gopower Smart Grid Co; LTD LBS 24KV 630a SF6 Gas Load Break Switch 24kV SF6 load break switch is a sf6 load break switch ...