33KV SF6 Gas Load Break Switch
33KV SF6 Gas Load Break Switch
These load break switch 33kvare intended for outdoor applications. They can be mounted either horizontally or vertically, and are suitable for electrical operation and power distribution by power distribution cabinet. These 33kv load break switch are tested by our quality controllers on various parameters before delivering them to our valued customer ends. We manufacture these switches with the help of cutting edge technology, which allows us to deliver a flawless product that is sure to be flawless as well. The 33 kV live parts are not directly touchable and hence guarantee protection from hazards.
33kv Load Break Switch Application
The 33kv pole mounted switch is made of a proven rugged, corrosion-resistant material (304L stainless steel plate for warships), ensuring a long service life (30 years) and a range of operations, with the characteristics ideal for on-column equipment.
33kv Load Break SwitchTechnical Parameters
|
Products Type |
FWX-36 |
|
Basic Ratings |
|
|
Maximum System Voltage |
36kV |
|
Rated Continuous Current |
630A |
|
Rated Frequency |
50/60Hz |
|
Short Time Withstand Current |
16kA/1sec |
|
Making and Breaking Capacity |
|
|
Mainly Active Load Current |
630A |
|
Number of Load-break Operations |
400times |
|
Short-circuit Making Current (peak) |
40kA |
|
Number of Making Operations |
5 times |
|
Cable Charging Current |
25A |
|
Line Charging Current |
|
|
Closed Loop Circuit Current |
630A |
|
Transformer Magnetizing Current |
22A |
|
Power Frequency Withstand Current Test |
|
|
Wet Condition-10sec Ph- Ph-Eth, Across Interrupters |
70kV |
|
DryCondition-1min, Ph- Ph, Phase to Earth |
95kV |
|
Dry Condition - 1 min Across Interrupter |
110kV |
|
Impulse Withstand Current Test( 1.2 x 50 µs ) |
|
|
Phase to Phase, Phase to Earth |
195kV |
|
Across Interrupter |
215kV |
|
Other Ratings & Specifications |
|
|
Internal Arc Test |
20kA /0.1 sec |
|
Arc Extinction Medium |
SF6 Gas |
|
Insulation Medium |
SF6 Gas |
|
Creepage Distance (Porcelain) |
1055mm |
|
Creepage Distance (Silicon) |
1550mm |
|
Dry arcing distance |
≥ |
|
IP Level |
65 |
|
Operation Performance |
|
|
Closing/Opening Time |
<1sec |
|
Mechanical Operations (Guaranteed) |
10000times |
|
Operating Temperature (*Manual Type) |
-25~+70℃ |
|
Gas Pressure |
|
|
Nominal Pressure (MPa, at 20°C) |
|
|
Bursting Pressure (MPa) |
|
|
Minimum Gas Pressure (MPa) |
|
|
Leakage Rate (cc/ sec) |
≤0.5% |
|
Voltage sensors |
|
|
CT ABC 10P10 5VA |
400:05:00 |
|
Incoming side and outgoing side of the voltage sensor |
6 Voltage sensor(built-in) |
|
Phase voltage:(24(36)kV/√3)/(3.25V/√3) |
|
|
Special attention should be paid to the voltage sensor, which must be directly fed by the 33KV load break interrupter switch. |
|
|
No additional adjustment circuit can be added to the controller. The voltage signal of the 33kv load break switch into the test line needs to be tested separately. |
|
GopowerElectrical Equipment & Supplies: Directly related to the production of electrical energy and transmission and distribution equipment called primary equipment. The auxiliary equipment that monitors, measures, controls and protects the primary equipment is the secondary equipment.
Now the price of automatic recloseris reasonable, if you have needs, please contact us.
Send product request
Other supplier products
| 11KV Vacuum Circuit Breaker | ZW32 series 11kv vacuum circuit breaker are used in distribution systems. 11kv auto reclosersare used to make and break normal and fault currents. ... | |
| Centralized Type DTU | The centralized DTU adopts high-performance MCU processor, high-speed industrial network communication technology, multi-CPU integration technology... | |
| 24KV Recloser Vacuum Circuit Breaker | The 24KV breaker switch unit is comprised of three poles, the operating mechanism, and the operating mechanism housing. The sequence of the poles i... | |
| LBS 24KV 630a SF6 Gas Load Break Switch | LBS 24KV 630a SF6 Gas Load Break Switch 24kV SF6 load break switch is a sf6 load break switch for medium voltage switchgear, using SF6 gas as ar... | |
| 11KV Auto Recloser Vacuum Circuit Breaker | ZW32 series 11 kv breakerare used in distribution systems. 11kv auto reclosers are used to make and break normal and fault currents. 11kv outdoor c... |
Same products
| HUAWEI TP48600B Data Center Indoor Modular Power Supply System | Seller: Hebei Chengyue Technology Co., Ltd | HUAWEI TP48600B Data center Indoor modular power supply systemis an AC/DC indoor combination powe... | |
| YCS 3060 Repair Power Supply for PCB Diagnostics | Seller: Phonefix | YCS 3060 30V 6A DC Power Supply delivers 180W high power for tablet/mobile phone motherboard repa... | |
| The Power Solution for Short Circuit Fixes and Soldering Repairs | Seller: Shenzhen Wikshu Technology Co. | Description TBK-219 Curved DC Regulated Power Supply with C210 Soldering Iron Short Circ... | |
| Short Circuit Detection Power Supply For Motherboard Repair | Seller: Shenzhen Wikshu Technology Co. | Description AIFEN 3006 30V 6V 180W DC Power Supply with 4-digits display for real time d... | |
| WPS Series Adjustable DC Power Supply – Precision Power for Your Electronics Projects | Seller: Shenzhen Wikshu Technology Co. | Description WPS series WPS305H WPS3010H WPS605H Adjustable DC Power Supply, an essential S... |