XLPE cable
500 KV XLPE Insulated Power Cable
Standard
We produced according to National Standard of GB/T 22078.2-2008 of the People’s Republic of China.
Range of application
It is suitable for single-core cable’s installation and operation under normal conditions of rated voltage 290/500 KV, but it is not suitable for cable in special use, such as submarine cable.
Characteristics of cable
●Rated voltage of cable is U0=290 KV、U=500 KV、Um=550 KV.
●The allowable maximum temperature of cable conductor is 90℃ when it runs in normal, and 250℃ when it short circuited (Longest time is 5 s).
●The allowable minimum bending radius is 20 times of cable outside diameter when installed. After installation , the minimum bending radius is recommended for 15 times of cable outside diameter.
Service environment( Place )
- Lead sheath cable, is suitable for environment with more serious corrosion but no much nitric acid, acetic acid and organic matter ( Such as mud, coal and strong alkaline corrosion matter with technical force, stress and vibration etc.)
- Aluminium sheath cable, is suitable for environment with minor corrosion and required to bear a certain mechanical force ( For example, connected with transformer directly and laying at bridge opening or in shaft etc.)
●Metal plastic compound sheath cable is suitable for general damp and warm place , no corrosion or light corrosion and no direct contact with water and bear not so much technical force , pulling force , stress and vibration.
- PVC outer sheath cableis mainly used in cable line with general fire-proof requirement and insulation requirement for outer sheath.
- PE outer sheath cableis mainly suitable for directly buried laying cable line with higher requirement on outer sheath insulation, low temperature environment under 20℃, or soaked place by chemical liquid and low toxicity requirement when cable burns, when PE outer sheath is used in tunnel or shaft , fire-control and flame-retardant measures should be adopted if necessary.
Send product request
Other supplier products
HV power cable | Rated Voltage 0.6/1.0 KV and Below PVC Insulated Power Cable Product Standard GB/T 12706-2008 standard equivalent to IEC502(2004). Usage This produ... | |
Rated Voltage 450/750 V and Below Rubber Sheathed&Insulated Soft Cable | Rated Voltage 450/750 V and Below Rubber Sheathed&Insulated Soft Cable Product Standard GB/T 5013-2008 ADOPTS IEC 60245. Usage This product is ... | |
500 KV XLPE Insulated Power Cable | 500 KV XLPE Insulated Power Cable Standard We produced according to National Standard of GB/T 22078.2-2008 of the People’s Republic of China.... | |
Rubber Cable | Mine Rubber Sheathed Soft Cable Product Standard GB 12972.1.2.5-91 Usage This product is suitable for use in rated voltage U0/U 0.38/0.66 KV coal-w... | |
AL Twiste Wire and ACSR Cable | AL Twiste Wireand ACSR Cable Product Standard GB/T 1179-2008, equivalent adoption of IEC61089-1997. Usage The product is suitable for overhead ... |