CU/LSZH H07Z-K LSZH Flexible Building Wire
H05Z-K and h07z k cables are referred nonsheath FLEXIBLE single-core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire with rated voltage up to and including 450/750V.
The maximum conductor operating temperature for the cables are 90℃and for fixed wiring application. it is often referred to as LSZH building wire.
H07Z-K are cables for fixed wiring. The conductor is in class 5. The size of cable is 1.5--240 mm2 with voltage 450/470. H05Z-k is for internal wiring. The conductor shall be class5 with a voltage of 300/300v. The size of the cables is 0.5-1mm².
We supply the cables according to BS EN 50525-3-41 and IEC 60227.
CU/LSZH H07Z-K LSZH Flexible Building Wire Parameter
AWG |
Nominal Thickness of Insulation |
Nominal Overall Diameter |
Nominal Copper Weight |
Nominal Weight |
|
# xmm² |
mm |
mm |
kg/km |
kg/km |
|
H07Z-K |
|||||
16(30/30) |
1 x 1.5 |
0,7 |
24 |
||
14(50/30) |
1 x 2.5 |
0,8 |
4 |
24 |
35 |
12(56/28) |
1 x 4 |
0,8 |
38 |
51 |
|
10(84/28) |
1 x 6 |
0,8 |
6 |
58 |
71 |
8(80/26) |
1 x 10 |
1,0 |
96 |
118 |
|
6(128/26) |
1 x 16 |
1,0 |
154 |
180 |
|
4(200/26) |
1 x 25 |
1,2 |
240 |
278 |
|
2(280/26) |
1 x 35 |
1,2 |
336 |
375 |
|
1(400/26) |
1 x 50 |
1,4 |
480 |
560 |
|
2/0(356/24) |
1 x 70 |
1,4 |
16 |
672 |
780 |
3/0(485/24) |
1 x 95 |
1,6 |
912 |
952 |
|
4/0(614/24) |
1 x 120 |
1,6 |
1152 |
1200 |
|
300 MCM (765/24) |
1 x 150 |
1,8 |
1440 |
1505 |
|
350 MCM (944/24) |
1 x 185 |
2,0 |
1776 |
1845 |
|
500MCM(1225/24) |
1 x 240 |
2,2 |
2304 |
2400 |
Description Of CU/LSZH H07Z-K LSZH Flexible Building Wire
- Conductor: plain annealed copper Class 5
- Insulation: LSZH
- Rated voltage: 450V/750V
- Operating temperature: -15℃~+90℃
- Min bending radius: more than 6 times of overall diameter。
Application Of CU/LSZH H07Z-K LSZH Flexible Building Wire
H07Z-K cables are used for the internal wiring of switchboards and distributor boards with voltage 1000v. They normally installed in conduit and trunking or can be surface mounted if used as earth cable. They are good options for using in public buildings to reduce the threat to life and equipment cased by smoke and toxic fumes. They can't be installed in concrete without mechanic protection.
If you want to know more information about cable 6181b, please contact us.
As a reliable cable provider,we will provide more high quality products for you.
Send product request
Other supplier products
2 Cores Power Cable (XLPE Insulated) | XLPE insulated 2 core power cableare normally used in power transmission and distribution systems. The 2 core XLPE cableis referred to as IEC60502 ... | |
Copper Tape Screened Control Cable | Copper tape screened control cable is mainly used in anti-interference circuit system. These copper control cables feature a plain annealed cu cond... | |
4 Cores +Earth Power Cable (XLPE Insulated) | The structure of 4 cores+1 earth is designed for application where the earth wires are required according to customer requirements. These 4 core an... | |
CU/PVC/PVC 6243Y Flat Three And Earth Cable | BS6004 6243Ycables refer to the flat three cores and circuit protective core (earth core) with a voltage of 300/500v. 6243y flat 3 core zhls cab... | |
CU/PVC/PVC 6242Y Flat Twin Cores And Earth Cable | BS6004 624-Y flat twin and earth cablerefer to the flat cores with the earth with a voltage of 300/500v. They could be single-core +earth 6241Y, tw... |