Copper Tape Screened Control Cable
Copper tape screened control cable is mainly used in anti-interference circuit system. These copper control cables feature a plain annealed cu conductor and PVC insulation and sheath mounting cu tape with a voltage of 450/750v. Copper wire control cable could be designed to have performance of LSZH, flame retardant and fire resistance according to requirement. It is normally referred to screen cable or CTS control cable, we supply these copper tape screen cable by standard of IEC 60227.
Copper Tape Screened Control Cable Parameter
Cross-Sectional Area Thickness of Insulation Thickness of Copper Tape Thickness of Sheath Overall Diameter (mm) Min resistance of insulation at 70℃ Max.D.C resistance of at 20℃ Approx Weight Approx Weight
mm² mm mm mm min max MΩ/km MΩ/km (kg/km) (kg/km)
4x0.75 0.6 0.05-0.1 1.2 8.1 9.7 0.012 24.5 144 144
4x1 0.6 0.05-0.1 1.2 8.4 10.2 0.011 18.1 153 153
4x1.5 0.7 0.05-0.1 1.2 9.5 11.4 0.011 12.1 190 190
4x2.5 0.8 0.05-0.1 1.5 10.9 13.1 0.01 7.41 276 276
4x4 0.8 0.05-0.1 1.5 12.5 15.1 0.0085 4.61 367 367
4x6 0.8 0.05-0.1 1.5 13.6 16.5 0.007 3.08 467 467
4x10 1 0.05-0.1 1.7 17.1 20.7 0.0065 1.83 728 728
7x0.75 0.6 0.05-0.1 1.2 9.3 11.2 0.012 24.5 178 178
7x1.0 0.6 0.05-0.1 1.2 9.7 11.7 0.011 18.1 209 209
7x1.5 0.7 0.05-0.1 1.5 11 13.3 0.011 12.1 239 239
7x2.5 0.8 0.05-0.1 1.5 13.3 16.1 0.01 7.41 398 398
7x4 0.8 0.05-0.1 1.5 14.6 17.6 0.0085 4.61 528 528
7x6 0.8 0.05-0.1 1.5 16 19.4 0.007 3.08 717 717
7x10 1 0.05-0.1 1.7 20.7 25.1 0.0065 1.83 1145 1145
10x0.75 0.6 0.05-0.1 1.5 11.3 13.7 0.012 24.5 214 214
10x1 0.6 0.05-0.1 1.5 12.5 15.1 0.011 18.1 300 300
10x1.5 0.7 0.05-0.1 1.5 14.2 17.2 0.011 12.1 367 367
10x2.5 0.8 0.05-0.1 1.7 16.5 20 0.01 7.41 572 572
10x4 0.8 0.05-0.1 1.7 18.6 22.5 0.0085 4.61 787 787
10x6 0.8 0.05-0.1 1.7 20.5 24.8 0.007 3.08 992 992
Description of Copper Tape Screened Control Cable
Conductor: Solid or Stranded Copper
Insulation: PVC/PVC(XLPE)
Screen: Copper tape Screen
Sheath: PVC
Rated voltages: 450/750V
Max. Continuous working temp of conductor:70
Upon short circuit (Max. Duration time 5s) the Max.
Temperature of conductor not higher than160°C;
Ambient temperature of installation not less than 0°C.
Standard: IEC 60227, IEC60228, AS/NZS 5000.2
China Standard: GB9330
Application Of Copper Tape Screened Control Cable
The control cable with copper tape for cable screen features moisture-proof, corrosion-resistant and damage-proof. These copper tape screen control cables widely used as the connecting wire of instrument insulation, control equipment and power distribution facilities.
As a professional flex cable factory, we can offer different kinds of low smoke zero halogen power cable for sale, if you are interested, please contact us.
Send product request
Other supplier products
Aerial Insulated Cable | Aerial cables are often referred to as overhead power cable, the conductor could be copper and aluminum. Jenuincable can supply different aerial ca... | |
ABC Cable (Aerial Bundled Cable) | Aerial Bundle Cables, normally referred to as Aerial Bundled Conductors or ABC, with 0.6/1kv, are called for combining multiple single-core cables ... | |
Bare Strand Copper Wire | The bare conductor cablealso are known as hard drawn bare copper conductor, ground copper and bare copper strand. They have two main types, the har... | |
CU/LSZH H05Z-K LSZH Flexible Building Wire | H05z k wire, h05z k cable,and h07z kcables are referred unsheath FLEXIBLE single-core cables insulated with halogen-free crosslinked compound and h... | |
3 Cores +1 Earth Power Cable (PVC Insulated) | Description of 3Cores+1 Earth Power Cable (PVC Insulated) Rated Temperature: 70℃ Rated Voltage: 600/1000V Reference Standard: GB/T12706, IEC... |