AC vacuum contactor HVJ5 1.14KV 1000A
- General
HVJ5 1.14 kv 1000AAC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems,with AC 50Hz-60Hz,rated voltage of 1,140Vand rated current to 1000A. It also can be equippedwith thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starterand so on.
- Main technical parameter
Rated voltage: 1140 V
Control voltage: 36 V, 110 V, 220 V, 380 V
Rated current: 1000A
Opening distance: 2±0.2mm
Over travel: 1±0.2mm
Final pressure: 30±3N
Main circuit power frequency voltage withstand: 4200 V
Auxiliary circuit power frequency voltage withstand: 2500 V
Control circuit power frequency voltage withstand: 2000 V
Making capacity: 10Ie,100times
Breaking capacity: 8Ie,25times
Limit breaking current(A): 10000,3times
Electricity life times AC3: 60*104
Electricity life times AC4: 1.5*104
Mechanical life times: 300*104
Overload capacity: 8Ie 10S
Remark: “Ie”is Rated current of main circuit.
Send product request
Other supplier products
AC vacuum contactor HVJ5-1.14kv 250A | General HVJ5 1.14 kv 250A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of ... | |
HCJ5 1.14kv 125A vacuum interrupter for vacuum contactor | HCJ5 1.14kv 125A vacuum interrupter for vacuum contactor The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact... | |
TD 12kv 1250A 31.5KA (JUC618) vacuum interrupter for VCB | Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstan... | |
AC vacuum contactor HVJ5 1.14kv 125A | General HVJ5 1.14kv 125AAC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC... | |
TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB | Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated pow... |
Same products
Rated Power 2400W 24VDC Solar Inverter | Seller: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24VDC Solar Inverter The DC 2.4 kw inverterwith a rated power of 2400 watts is... | |
Rated Power 2400W 24VDC PV Inverter | Seller: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24VDC PV Inverter This is a single phase inverter rated at 2400 watts, 24 volt... | |
Rated Power 2400W 24VDC Pure Sine Wave Solar Inverter | Seller: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24 Volt Pure Sine Wave Inverter It is a new generation of power inverter with ... | |
Rated Power 2400W 24VDC Off Grid Solar Inverter | Seller: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24VDC Off Grid Solar Inverter This is a cost-effective solar inverter that acc... | |
Rated Power 2400W 24VDC Battery Inverter | Seller: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24VDC Battery Inverter The Rated Power 2400W 24VDC Battery Inverter is a mid-r... |