24KV SF6 Gas Load Break Switch
Application of 24KV SF6 Gas Load Breaker Switch
The SF6 LBS 24kv 630Agas-insulated switch is a three-phase interoperable switching device designed for use in distribution system cabling and overhead power line segment applications.
The 24KVpole mounted switchcan be operated manually in the field or remotely from the control center.
Technical Parameters of 24KV SF6 Gas Load Breaker Switch
Products Type |
FWX-24 |
Basic Ratings |
|
Maximum System Voltage |
24kV |
Rated Continuous Current |
630A |
Rated Frequency |
50/60Hz |
Short Time Withstand Current |
16kA/1sec |
Making and Breaking Capacity |
|
Mainly Active Load Current |
630A |
Number of Load-break Operations |
400times |
Short-circuit Making Current (peak) |
40kA |
Number of Making Operations |
5 times |
Cable Charging Current |
25A |
Line Charging Current |
|
Closed Loop Circuit Current |
630A |
Transformer Magnetizing Current |
22A |
Power Frequency Withstand Current Test |
|
Wet Condition-10sec Ph- Ph-Eth, Across Interrupters |
50kV |
DryCondition-1min,Ph- Ph, Phase to Earth |
64kV |
Dry Condition - 1 min Across Interrupter |
79kV |
Impulse Withstand Current Test( 1.2 x 50 µs ) |
|
Phase to Phase, Phase to Earth |
125kV |
Across Interrupter |
145kV |
Other Ratings & Specifications |
|
Internal Arc Test |
20kA /0.1 sec |
Arc Extinction Medium |
SF6 Gas |
Insulation Medium |
SF6 Gas |
Creepage Distance (Porcelain) |
700mm |
Creepage Distance (Silicon) |
1200mm |
Dry arcing distance |
≥ |
IP Level |
65 |
Operation Performance |
|
Closing/Opening Time |
<1sec |
Mechanical Operations (Guaranteed) |
10000times |
Operating Temperature (*Manual Type) |
-25~+70℃ |
Gas Pressure |
|
Nominal Pressure (MPa, at 20°C) |
|
Bursting Pressure (MPa) |
|
Minimum Gas Pressure (MPa) |
|
Leakage Rate (cc/ sec) |
≤0.5% |
Voltage sensors |
|
CT ABC 10P10 5VA |
400:05:00 |
Incoming side and outgoing side of the voltage sensor |
6 Voltage sensor(built-in) Phase voltage:(24(36)kV/√3)/(3.25V/√3) |
Special attention should be paid to the voltage sensor, which must be directly fed by theLBS load break switch. No additional adjustment circuit can be added to the controller. The voltage signal of the switch into the test line needs to be tested separately. |
Gopoweris one of the earliest high-tech electric power equipment ltdengaged in R&D and production of (12KV-40.5kV) medium-voltage transmission and distribution intelligent control equipment in China.
Send product request
Other supplier products
15KV SF6 Gas Load Break Switch | 15 kv pole mounted disconnect switch is suitable for rated voltage 15kV, rated current 630A, 50/60Hz distribution network breaking. The load curren... | |
SF6 Gas 11 KV Load Break Switch | The load break switch 11kvis suitable for the distribution network with the highest voltage 11kV, the rated current 630A, and the rated frequency 5... | |
11KV Vacuum Circuit Breaker | 11KV Vacuum Circuit Breaker ZW32 series 11kv breakerare used in distribution systems. 11kv auto reclosers are used to make and break normal and fa... | |
Control Box-Feeder Terminal Unit | The feeder remote terminal unit(FTU) is a new HV switch control device of control cabinet enclosures equipped with both the imported DSP high-speed... | |
Pole Mounted Switch | The pole mounted disconnect switchis a kind of safety switch used on the electric pole to ensure the safety of electricity. Its main function is to... |