Easy Assembly DC immunity 10-100A Current Transformer

Spec can be requested
DC immunity
Dielectric strength: not less than 4kV/1mA/1min
Insulation resistance: >500M Ohm (500V DC)
Operating temperature: -40 to +85 Degrees Celsius
Relative humidity: less than or equal to 95% (25 Degrees Celsius) Altitude: less than or equal to 10000m
Covering:Epoxy Resin
Suitable for kWh meter class 0.2, class 0.5, class 1.0.
Typical AC current measurement error is within 0.02% at Ib test point
Typical phase shift is at 1-10', additional compensation is not needed
Fully enclosed case, with high function of current isolation and nice outline
Customized product is welcomed and the free sample can be provided
Certificate : CE, ROHS
Small orders are accepted
High quality products with very competitive price


Send product request

To: Deqing GIG Electronic Co., Ltd
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Power Meter Use Delicate Appearance 1:2500 Current Transformer
Power Meter Use Delicate Appearance 1:2500 Current Transformer Regular spec: Primary current: 5A Imax: 100A Accuracy class (%): 0.1 Turns Ratio:1:2500 Load resistance: 10 Ohm Frequency: 50HZ-60HZ Dielectric Wit...
PCB Use 10(40)A High Dielectric Strength Mini Current Transformer
PCB Use 10(40)A High Dielectric Strength Mini Current Transformer Regular spec: Primary Current: 10A Imax: 40A Accuracy Class: 0.2% Turns Ratio: 1:1000 Frequency: 50HZ Load resistance: 10 Ohm Withstanding Volt: 4K...
Space Saving Design ROHS Compliance Quick connection to PCB Current Transformer
Space Saving Design ROHS Compliance Quick connection to PCB Current Transformer Primary current: 5A Imax: 120A Accuracy class: 0.1% Turns ratio: 1:2500 Frequency: 50HZ-60HZ Load resistance: 20 Ohm Turns Ratio: 0.1% Withstanding...
Adopted High Permeability Core Flexible wires Instrument Use Current Transformer
Adopted High Permeability Core Flexible wires Instrument Use Current Transformer Primary current: 1A Imax: 10A Accuracy class: 0.1% Load resistance: 10 Ohm Frequency: 50-60Hz Dielectric withstanding volt (Hi-pot): 4KVrms Ambient...
Electricity Meter Busbar Type Low Error Current Transformer
Electricity Meter Busbar Type Low Error Current Transformer 1.Regular spec: 10 (100)A/4mA Other spec can be request Dielectric strength: not less than 4kV/1mA/1min Insulation resistance: >500M Ohm (500V D...
All supplier products

Same products

China factory Transformer bushing BRDW-126/630-3 for power station
China factory Transformer bushing BRDW-126/630-3 for power station Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel...
TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER Seller: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter