High Accuracy Three-phase Power Measurement Application Current Transformer

Spec can be requested:
Primary current: 5A
Imax: 60A
Accuracy class: 0.1%
Load resistance: 20 Ohm
Frequency: 50Hz-60Hz
Dielectric withstanding volt (Hi-pot): 4KVrms
Ambient temp: -40-+70 Degrees Celsius
Storage temp: -40-+80 Degrees Celsius
DC immunity
Dielectric strength: not less than 4kV/1mA/1min
Insulation resistance: >500M Ohm (500V DC)
Operating temperature: -40 to +85 Degrees Celsius
Relative humidity: less than or equal to 95% (25 Degrees Celsius) Altitude: less than or equal to 10000m
Covering: Epoxy Resin
Suitable for kWh meter class 0.2, class 0.5, class 1.0.
Typical AC current measurement error is within 0.02% at Ib test point
Typical phase shift is at 1-10', additional compensation is not needed
Fully enclosed case, with high function of current isolation and nice outline003B


Send product request

To: Deqing GIG Electronic Co., Ltd
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Adopted High Permeability Core Flexible wires Instrument Use Current Transformer
Adopted High Permeability Core Flexible wires Instrument Use Current Transformer Primary current: 1A Imax: 10A Accuracy class: 0.1% Load resistance: 10 Ohm Frequency: 50-60Hz Dielectric withstanding volt (Hi-pot): 4KVrms Ambient...
Power Meter Use Delicate Appearance 1:2500 Current Transformer
Power Meter Use Delicate Appearance 1:2500 Current Transformer Regular spec: Primary current: 5A Imax: 100A Accuracy class (%): 0.1 Turns Ratio:1:2500 Load resistance: 10 Ohm Frequency: 50HZ-60HZ Dielectric Wit...
Electric Meter High Sensitivity 1:2500 Current Transformer
Electric Meter High Sensitivity 1:2500 Current Transformer 1.Regular spec: 10 (100)A/4mA Other spec can be request Dielectric strength: not less than 4kV/1mA/1min Insulation resistance: >500M Ohm (500V D...
Three Phase Imax 50A Prepayment meter Use Current Transformer
Three Phase Imax 50A Prepayment meter Use Current Transformer Regular spec: Housing material: anti-burning ABS Ambient temperature: -40 to +85 Degrees Celsius Insulation resistance: more than or equal to 500M ...
Three Phase Power Meter Use 1:2000 Current Transformer
Three Phase Power Meter Use 1:2000 Current Transformer 1.Regular spec: 10 (100)A/4mA Other spec can be request Dielectric strength: not less than 4kV/1mA/1min Insulation resistance: >500M Ohm (500V D...
All supplier products

Same products

China factory Transformer bushing BRDW-126/630-3 for power station
China factory Transformer bushing BRDW-126/630-3 for power station Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel...
TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER Seller: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...