ZBW Type Prefabricated Substation,mobile transformer substation,distribution transformer substation,power substation transformer
ZBW Type Prefabricated Substation,mobile transformer substation,distribution transformer substation,power substation transformer
ZBW Type Prefabricated Substation
ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 “high and low voltage prefabricated substation” and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation.
Product Description
ZBW packaged substation, also known as prefabricated substation. It meet GB17467-1998 “high and low voltage prefabricated substation” and IEC1330 standards etc. As a new type of power supply and distribution device, has more advantages than traditional civil substation. Such as smaller size, smaller floor area, compact structure, flexible movement, which greatly reduce period and area for construction in site, also the construction cost. Meanwhile, prefabricated substation is easy to be installed at site , can realize rapid power supply, almost maintenance free. Most particularly, it is placed at load center so that reduce power loss effectively to improve power quality, enhance the reliability of power supply and also is significant for distribution network transformation.
This substation fulfills the functions such as transformation of energy, distribution, transmission, metering, compensation, system control, protection and communication.
The ZBW prefabricated substation is composed by the high-voltage switchgear, low-voltage distribution panel, distribution transformer and enclosure. The high-voltage switchgear adoptsair load switch and the transformer is dry-type or oil immersed type. The substation adopts good ventilation structure with elegant appearance and good heat-insulating performance. The temperature rise of the compartments caused by the outdoor solar radiation can be reduced to within the lowest limits on account of the upper and lower ventilation windows. The forced ventilation device and the temperature auto-controlled device should be installed in the substation. The systems of control, protection, live display and the lighting are equipped in each separate unit.
Product Features
Application
The type of small unattended substation is applicable for voltage up to 35KV, with main transformer capacity up to 5000KVA, is widely used in urban industrial substation, 10KV ring network system, rural power grid 35KV substation and other occasions.
Main Function
This substation fulfills the functions such as transformation of energy, distribution, transmission, metering, compensation, system control, protection and communication.
Main Characters
The primary and secondary equipments are pre-installed in the cabinet which is removable, full-sealed, automatic temperature controlled, antiseptic, damp proof and rustproof. It only needs to be installed on the cement foundation after arriving at the site. This kind of substation have the advantages of low investment, short construction period, small occupation area and easy environmental coordination.
Model and Meaning
Technical Parameter of ZBW Prefabricated Substation
Description |
Unit |
Data |
|
HVcompartment |
Rated Frequency |
Hz |
50 |
Rated voltage |
kV |
6 10 35 |
|
Max operating voltage |
kV |
||
Power frequency withstand voltage(phase to ground and between phases)/ disconnector fracture |
kV |
32/36 42/48 95/118 |
|
lightning impulse withstand voltage(phase to ground and between phases)/ disconnector fracture |
kV |
60/70 75/85 185/215 |
|
Rated current |
A |
400 630 |
|
Ratedshort-time withstand current |
kA |
||
Rated peak withstand current |
kA |
||
LVcompartment |
Rated voltage |
V |
380 200 |
Rated current of main circuit |
A |
100~3200 |
|
Rated short-time withstand current |
kA |
15 30 50 |
|
Rated peak withstand current |
kA |
30 63 110 |
|
Branch current |
A |
10 ~800 |
|
Number of branch circuits |
/ |
1 ~12 |
|
Compensation capacity |
kVA R |
0 ~360 |
|
Transformer |
Rated capacity |
kVA |
50~2000 |
Short-circuit impedance |
% |
4 6 |
|
Tapping range |
/ |
±2×2.5% ±5% |
|
Connection group symbol |
/ |
Yyn0 Dyn11 |
Technical Parameters
Notes to the ordering of the Prefabricated Substation
Way of incoming: terminal type, ring type or double power in.
Whether there ishigh voltage metering or not. If yes, the position of the meter(front of the switch or behind the switch), the requirement of the meter gauge and its supplier is designated or not.
Type of the HV switch, one way is using the combination with high voltage vacuum load switch and the fuse, which is mainly used and economical; the other is adopting the disconnector switch and the vacuum breaker, which is used for the high capacity transformer and with higher price.
Switch Supplier.
The number of the outgoing ways and the rated current value of each outgoing switch.
Whether there isthe compensation or not, if yes, the capacity of the compensation.
Whether with the metering or not. If yes, the position is necessary.
We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
Send product request
Other supplier products
GGD Low Voltage Fixed-mounted Switchgear,Fixed mounted Switchgear,Low Voltage Switchgear,High and Low Voltage Switchgears | GGD Low Voltage Fixed-mounted Switchgear,Fixed mounted Switchgear,Low Voltage Switchgear,High and Low Voltage Switchgears GGD series low voltage sw... | |
Dry type Power Transformers | Product Description SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) d... | |
Characteristics and properties of amorphous alloy transformer | is a new type of energy saving transformer made of a new magnetic conducting material (amorphous alloy). It is more than 70% lower than the no-loa... | |
How much damage does the electromagnetic radiation of the power transformer have on the body? | How much does the electromagnetism radiation of power transformer harm to the body? Distribution transformer substation suppliershares that with t... | |
three-phase transformer | The principle ofandis the same as that of ordinary transformer. All by electromagnetic induction. Isolation transformer generally refers to 380V/3... |
Same products
ACREL AID150 ALARM AND DISPLAY DEVICE | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
ACREL ANSVG STATIC VAR GENERATOR | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
The Working Principle of Active Power Filter | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... | |
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane... | |
ACREL DTSD1352-C SOLAR INVERTER SMART METER | Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Acrel sungrow smart meterDTSD1352 din rail type multi-function energy meter is an intelligent ins... |