Dry type Power Transformers
Product Description
SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) dry-type transformers to ensure that the products fully meet the requirements such as fire prevention, waterproof ,environmental protection. It is the ideal product for distribution systems and widely used in the subway, shipbuilding, mining, chemical, power companies and personnel-intensive buildings as well as other special requirements of the occasion for safety.
Model and Meaning
SC(B)10 Series Resin-insulated Dry Type Transformer
SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers
Technical Parameter for6kV, 10kV& 30kVA-2500kVA With Off Circuit Dry Type Transformer
Rated capacity(KVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
30 |
±2X2.5%±5% |
Dyn11Yyn0 |
190 |
670 |
710 |
760 |
||||
50 |
270 |
940 |
1000 |
1070 |
||||||
80 |
370 |
1290 |
1380 |
1480 |
||||||
100 |
400 |
1480 |
1570 |
1690 |
||||||
125 |
470 |
1740 |
1850 |
1980 |
||||||
160 |
540 |
2000 |
2130 |
2280 |
||||||
200 |
±2X2.5%±5% |
620 |
2370 |
2530 |
2710 |
|||||
250 |
720 |
2590 |
2760 |
2960 |
||||||
315 |
880 |
3270 |
3470 |
3730 |
||||||
400 |
980 |
3750 |
3990 |
4280 |
||||||
500 |
1150 |
4590 |
4880 |
5230 |
||||||
630 |
1340 |
5530 |
5880 |
6290 |
||||||
630 |
1300 |
5610 |
5960 |
6400 |
||||||
800 |
1520 |
6550 |
6960 |
7460 |
||||||
1000 |
1770 |
7650 |
8130 |
8760 |
||||||
1250 |
2090 |
9100 |
9690 |
10300 |
||||||
1600 |
2450 |
11000 |
11700 |
12500 |
||||||
2000 |
3050 |
13600 |
14400 |
15500 |
||||||
2500 |
3600 |
16100 |
17100 |
18400 |
||||||
1600 |
2450 |
1220 |
12900 |
13900 |
||||||
2000 |
3050 |
15000 |
15900 |
17100 |
||||||
2500 |
3600 |
17700 |
18800 |
20200 |
Notes:The load losses listed in the table are the values of the reference temperature for different insulation systems inparentheses; The load losses under other insulation system temperatures that are not included in the table should be according to their respective reference temperatures, the corresponding calculation is based on the"- 155 ℃(F)" insulation system temperature data.
Notes:The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
Send product request
Other supplier products
How to Dry the Transformer? | Transformers such asOil Immersed Transformerare sometimes wet, especially in the summer when the transformer is relatively powerful, and the power... | |
three phase variable transformer | 3 phase step down transformer Oil Immersed Transformer Model and Meaning Model No. Rated CapacityKVA Rated Voltage KV Connection Group Sy... | |
SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers,Dry type Power Transformers,hermetically sealed transformers,dry type transformer | SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers,Dry type Power Transformers,hermetically sealed transformers,dry type transfo... | |
What\'s the transformer for? | Transformer is the core of power equipment, such as3 phase power transformer,which is closely related to people's production and life. It is made b... | |
high quality oil transformer | Do you know what the short circuit impedance of transformer is? Transformer such as the, it is an important electrical equipment, in the process... |
Same products
S11-M Power Transformer | Seller: Bokong Electric Co., Ltd | S11-M Product Description S11-M a new generation of low noise and low loss transformer devel... | |
Compact Transformer | Seller: Shaanxi Hanzhong Transformer Co., ltd | As a leading compact transformer substationmanufacturer and box type substation supplier, SEC com... | |
Combined Pad Mounted Substation | Seller: Shaanxi Hanzhong Transformer Co., ltd | Combined Pad Mounted Substation The ZBG series America Housing Type Transformer are researched a... | |
Amorphous Alloy Dry Type Transformer | Seller: Shaanxi Hanzhong Transformer Co., ltd | SCBH15eres amorphous alloy dry type transformerpertorms well not only for its excellent propertie... | |
35KV Power Transformer | Seller: Shaanxi Hanzhong Transformer Co., ltd | This 35 KV transformerhas the characteristics of high efficiency and low loss, can save a lot of ... |