XLPE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Single Pair)

XLPE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Single Pair)RE-2X(St)H 90°C / 300VSTANDARDSBasic design to EN 50288-7APPLICATIONInstrument cable minimizes noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations.The unarmoured LSZH sheathed cables are generally use for indoor installation and suitable for wet and damp areas. Generally, the cables are used within industrial process manufacturing plants for communication, data and voice transmission signals and services. Also used for the interconnection of electrical equipment and instruments, the LSZH sheath can reduce toxic smoke and fume emission.FIRE PERFORMANCEFlame Retardance (Single Vertical
Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)***EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Sunlight ResistanceUL 1581 section 1200Oil Resistance**ICEA S-73-532VOLTAGE RATING300VCABLE CONSTRUCTIONConductor:Annealed copper solid or plain copper stranded to IEC 60228 Class 2.Insulation:Extruded cross-linked XLPE compound, EN 50290. 2-29.Pair:Two insulated conductors uniformly twisted together with a lay not exceeding 100mmBinder tape:PETP transparent tapeOverall Screen:Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm²Outer Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.COLOUR CODEInsulation:Black / White, continuously numbered on white core(1, 2..)for multipair.Outer Sheath:Black or blue for intrinsically safe systemsPhysical AND THERMAL PROPERTIESTemperature Range During Operation (Fixed State):-30°C – +90°CTemperature Range During Installation (Mobile State):-5°C – +50°CMinimum Bending Radius:7.5 X Overall DiameterCONSTRUCTION PARAMETERS
Cable CodeRE-2X(St)HNo. of Pairs x2xCross SectionNominal Insulation ThicknessNominal Outer Sheath ThicknessNominal Overall DiameterApprox. WeightNo.x2xmm2mmmmmmkg/kmRE-2X(St)H 1P0.51x2x0.500.350.85.238RE-2X(St)H 1P0.751x2x0.750.380.85.649RE-2X(St)H 1P1.01x2x1.00.400.96.356RE-2X(St)H 1P1.31x2x1.30.450.96.865RE-2X(St)H 1P1.51x2x1.50.450.97.171Note : Other conductor sizes & core configurations are available upon request. Electrical PROPERTIES
Conductor Area Sizemm 20.50.751.01.31.5Insulation thickness (nominal)mm0.40.40.40.450.45Conductor resistance (20°C)Ω/km36.72518.514.212.3Insulation resistance (20°C)MΩ.km(Min.)5000Mutual Capacitance (1 kHz)pF/m(Max.)115≤ 4 pairsall other pairs7575758585Capacitance unbalance(1 kHz)pF/500 m (Max.)500InductancemH/km (Max.)1L / R (ratio) (max.)μH/Ω2525254040Operating voltage UrmsV300Test VoltageCore to CoreV1500Core to ScreenV1500
Other supplier products
|
|
NTSCGERLWOEU 3.6/6kV Flexible Submersible Cable VDE 0250 Part 813 |
NTSCGERLWOEU 3.6/6kV Flexible Submersible Cable VDE 0250 Part 813ApplicationsThese cables are used for permanent operation inwater where the cable ... |
|
|
H05V-R/H07V-R |
VDE Industrial Cables H05V-R/H07V-RApplication and DescriptionThese cables are preferably for installation indoors,Website:, in cable ducts and in ... |
|
|
NSSHOEU .../3E + ST 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812 |
NSSHOEU .../3E + ST 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812ApplicationsThese cables are designed for the connection of mobile equipment... |
|
|
600 1000V XLPE Insulated, PVC Sheathed, Screened Power Cables (3C+3E) |
600/1000V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (3C+3E)CU/XLPE/CUTO/PVC 600/1000V Class 2Application:The cables are designed... |
|
|
0.6/1 KV XLPE Insulated, LSOH (SHF1) Sheathed Flame Retardant Power Control Cables (Single Core) |
0.6/1 kV XLPE Insulated,Website:, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Single Core)ApplicationThese unarmoured power & cont... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |