.

N2XRY

German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts and in the open where better mechanical protection is required, or for higher tensile stress during installation and operation. Suitable for comparatively high ambient temperature due to high maximum permissible conductor temperature.Standard and ApprovalIEC 60502-1, VDE 0276-604, BS5467Cable Construction1- Solid or stranded, plain copper conductor- to DIN VDE 0295 cl. 1 or cl. 2, BS 6360 cl. 1 or cl. 2 and IEC 60228 cl. 1 or cl. 22- Cross-linked polyetdylene 2XI1 acc. to VDE 0276-604- Color coded to DIN VDE 0293(HD 308)- PVC filler4- Galvanized round steel / aluminum wire armour5- PVC outer jacket DMV5 to HD 603.1Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 3500 volts- Minimum bending radius: 15 x Ø- Flexing temperature: -5º C to +70º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +250º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²CONDUCTORTYPETHICKNESS OF INSULATION MMTHICKNESS OF SHEATH MMNOMINALOVERALL DIAMETER MMCABLE WEIGHT KG / KM41x25rm0.91.816.650321x35rm0.91.817.761211x50rm11.819.57832/01x70rm1.11.821.510143/01x95rm1.11.823.512804/01x120rm1.21.826.01575300mcm1x150rm1.41.827.51872350mcm1x185rm1.61.830.02294500mcm1x240rm1.71.933.02923750mcm1x300rm1.82.136.03509-1x400rm2240.54534-1x500rm2.22.345.05691-1x630rm2.42.549.57267-1x800rm0.71.856.59271162x1.5re/rm0.71.813.6325142x2.5re/rm0.71.814.5379122x4re/rm0.71.815.7448102x6re/rm0.71.816.853082x10rm0.71.819.478362x16rm0.71.822.098242x25rm0.91.825.5144722x35rm0.91.828.0176512x50rm11.930.521062/02x70rm1.1235.027653/02x95rm1.12..239.537464/02x120rm1.22.343.54465300mcm2x150rm1.42.547.55303350mcm2x185rm1.62.654.06890500mcm2x240rm1.72.859.58463750mcm2x300rm1.83.165.010151163x1.5re/rm0.71.814.1351143x2.5re/rm0.71.815.1415123x4re/rm0.71.816.3503103x6re/rm0.71.817.560383x10rm0.71.820.590363x16rm0.71.823.0116143x25rm0.91.827.0170923x35rm0.91.829.5212713x50sm11.931.524242/03x70sm1.11.936.534383/03x95sm1.1240.043434/03x120sm1.22.243.55172300mcm3x150sm1.42.349.56675350mcm3x185sm1.62.554.07977500mcm3x240sm1.72.660.09995750mcm3x300sm1.82.865.011990164x1.5re/rm0.71.814.9395144x2.5re/rm0.71.816.0470124x4re/rm0.71.817.4575104x6re/rm0.71.819.579884x10rm0.71.822.0105864x16rm0.71.825.5151844x25rm0.91.829.0205524x35rm0.91.932.0258514x50sm1235.530402/04x70sm1.12.141.043053/04x95sm1.12.245.054764/04x120sm1.22.451.57064300mcm4x150sm1.42.557.58536350mcm4x185sm1.62.761.510189500mcm4x240sm1.72.868.012772750mcm4x300sm1.8373.515380165x1.5re/rm0.71.815.8441145x2.5re/rm0.71.817.0535125x4re/rm0.71.819.3768105x6re/rm0.71.821.092185x10rm0.71.823.5123565x16rm0.71.827.0176545x25rm0.91.831.5242325x35rm0.91.934.5305715x50rm1.12.240.04099

Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Harmonized Code Industrial Cables H05V2-U H07V2-U
Harmonized Code Industrial Cables H05V2-U H07V2-U Harmonized Code Industrial Cables H05V2-U/H07V2-U Application and DescriptionThese cables are for fixed protected installation inside appliances an...
H05G-K/H07G-K
H05G-K/H07G-K German Standard Industrial Cables H05G-K/H07G-KApplication and DescriptionThese cables are recommended for tde internal wiring of switchboards and ...
300/500V Mica+XLPE Insulated Individual And Overall Screened Fire Resistant Instrumentation Cables
300/500V Mica+XLPE Insulated Individual And Overall Screened Fire Resistant Instrumentation Cables 300/500V Mica+XLPE Insulated Individual And Overall Screened fire resistant Instrumentation CablesRE-2X(St)H PiMF...CI. FE 180 PH30 ( CU/MGT+XLPE/I...
[FA-] TTY, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCY
[FA-] TTY, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCY 250V [FA-] TTY,Website:, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCYStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONCo...
LiYW
LiYW German Standard Industrial Cables LiYW Application and DescriptionThese thermal insulated wires are ideal for use in power current installation,Web...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes