.

N2XRY

German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts and in the open where better mechanical protection is required, or for higher tensile stress during installation and operation. Suitable for comparatively high ambient temperature due to high maximum permissible conductor temperature.Standard and ApprovalIEC 60502-1, VDE 0276-604, BS5467Cable Construction1- Solid or stranded, plain copper conductor- to DIN VDE 0295 cl. 1 or cl. 2, BS 6360 cl. 1 or cl. 2 and IEC 60228 cl. 1 or cl. 22- Cross-linked polyetdylene 2XI1 acc. to VDE 0276-604- Color coded to DIN VDE 0293(HD 308)- PVC filler4- Galvanized round steel / aluminum wire armour5- PVC outer jacket DMV5 to HD 603.1Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 3500 volts- Minimum bending radius: 15 x Ø- Flexing temperature: -5º C to +70º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +250º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²CONDUCTORTYPETHICKNESS OF INSULATION MMTHICKNESS OF SHEATH MMNOMINALOVERALL DIAMETER MMCABLE WEIGHT KG / KM41x25rm0.91.816.650321x35rm0.91.817.761211x50rm11.819.57832/01x70rm1.11.821.510143/01x95rm1.11.823.512804/01x120rm1.21.826.01575300mcm1x150rm1.41.827.51872350mcm1x185rm1.61.830.02294500mcm1x240rm1.71.933.02923750mcm1x300rm1.82.136.03509-1x400rm2240.54534-1x500rm2.22.345.05691-1x630rm2.42.549.57267-1x800rm0.71.856.59271162x1.5re/rm0.71.813.6325142x2.5re/rm0.71.814.5379122x4re/rm0.71.815.7448102x6re/rm0.71.816.853082x10rm0.71.819.478362x16rm0.71.822.098242x25rm0.91.825.5144722x35rm0.91.828.0176512x50rm11.930.521062/02x70rm1.1235.027653/02x95rm1.12..239.537464/02x120rm1.22.343.54465300mcm2x150rm1.42.547.55303350mcm2x185rm1.62.654.06890500mcm2x240rm1.72.859.58463750mcm2x300rm1.83.165.010151163x1.5re/rm0.71.814.1351143x2.5re/rm0.71.815.1415123x4re/rm0.71.816.3503103x6re/rm0.71.817.560383x10rm0.71.820.590363x16rm0.71.823.0116143x25rm0.91.827.0170923x35rm0.91.829.5212713x50sm11.931.524242/03x70sm1.11.936.534383/03x95sm1.1240.043434/03x120sm1.22.243.55172300mcm3x150sm1.42.349.56675350mcm3x185sm1.62.554.07977500mcm3x240sm1.72.660.09995750mcm3x300sm1.82.865.011990164x1.5re/rm0.71.814.9395144x2.5re/rm0.71.816.0470124x4re/rm0.71.817.4575104x6re/rm0.71.819.579884x10rm0.71.822.0105864x16rm0.71.825.5151844x25rm0.91.829.0205524x35rm0.91.932.0258514x50sm1235.530402/04x70sm1.12.141.043053/04x95sm1.12.245.054764/04x120sm1.22.451.57064300mcm4x150sm1.42.557.58536350mcm4x185sm1.62.761.510189500mcm4x240sm1.72.868.012772750mcm4x300sm1.8373.515380165x1.5re/rm0.71.815.8441145x2.5re/rm0.71.817.0535125x4re/rm0.71.819.3768105x6re/rm0.71.821.092185x10rm0.71.823.5123565x16rm0.71.827.0176545x25rm0.91.831.5242325x35rm0.91.934.5305715x50rm1.12.240.04099

Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

450/750V LSZH Sheathed (multicore)
450/750V LSZH Sheathed (multicore) 450/750V LSZH Sheathed (multicore) Application:The cables are mainly used in power stations,Website:, mass transit underground passenger systems, a...
150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened Flame Retardant Instrumentation Control Cables (Multipair/Multitriple)
150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened Flame Retardant Instrumentation Control Cables (Multipair/Multitriple) 150/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Overall Screened Flame Retardant Instrumentation & Control Cables (Multipair/Multitriple)Ap...
Type SHD-GC Three-Conductor Portable Power Cable, CPE Jacket 5kV ICEA S-75-381
Type SHD-GC Three-Conductor Portable Power Cable, CPE Jacket 5kV ICEA S-75-381 Type SHD-GC Three-Conductor Portable Power Cable,Website:, CPE Jacket 5kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for applica...
N2XFGY/ NA2XFGY
N2XFGY/ NA2XFGY German Standard Industrial Cables N2XFGY/ NA2XFGYApplication and DescriptionN2XFGY/ NA2XFGY cables are for lying in eartd,Website:, indoors, in duc...
600/1000V LSZH Sheathed, AL. Wire Armoured (single Core)
600/1000V LSZH Sheathed, AL. Wire Armoured (single Core) 600/1000V LSZH Sheathed,Website:, AL. wire Armoured (single core) Application:The cables are mainly used in power stations, mass transit undergroun...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes