H07RN-F

VDE Standard Industrial Cables H07RN-FApplication and DescriptionThese cables are designed to provide high flexibility and have the capacity to witdstand weatder,Website:, oils/ greases, mechanical and tdermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also suitable for fixed installations on plaster, temporary buildings and residential barracks and for use in drainage and water treatment, cold environments and severe industrial environments. Max operating voltage in single or three phase system is Uo/U 476/825 volts. In a direct current system max operating voltage is Uo/U 619/1238 volts. If in a fixed or protected installation Uo/U is 600/1000 volts. These cables are resistant to flame, acids, and oil penetration.Standard and ApprovalHD22.4 S3, VDE-0282 Part-4, CEI 20-19/4 / 20-35 (EN60332-1), IEC 60245-4, CE low voltage directive 73/23/EEC & 93/68/EEC., ROHS compliantCable Construction- Fine bare copper strands- Strands to VDE-0295 Class-5, IEC 60228 Class-5- Rubber core insulation EI4 to VDE-0282 Part-1- Color code VDE-0293-308 and HD 186- Green-yellow grounding, 3 conductors and above- Polychloroprene rubber (neoprene) jacket EM2Technical Characteristics- Working voltage: 450/750 volts- Test voltage: 2500 volts- Flexing bending radius: 6 x Ø- Fixed bending radius: 4.0 x Ø- Flexing Temperature: -25º C to +60º C- Fixed Temperature: -40º C to +60º C- Short circuit temperature: +200 º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA# X MM²NOMINAL THICKNESS OF INSULATIONMMNOMINAL THICKNESS OF SHEATHMMNOMINAL OVERALL DIAMETERMM MIN-MAXNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KM17(32/32)2 x 10.81.37./32)3 x 10.81.48.3-10./32)4 x 10.81.59.2-11./30)1 x 1.50.81.45.7-7.114.45916(30/30)2 x 1.50.81.58.5-11./30)3 x 1.50.81.69.2-11./30)4 x 1.50.81.710.2-13./30)5 x 1.50.81.811.2-14./30)7 x 1.50.82.614.5-17./30)12 x 1.50.82.917.6-22./30)19 x 1.50.83.220.7-26./30)24 x 1.50.83.524.3-30./30)1 x 2.50.91.46.3-7.9247214(50/30)2 x 2.50.91.710.2-13./30)3 x 2.50.91.810.9-14./30)4 x 2.50.91.912.1-15./30)5 x 2.50.92.013.3-17./30)7 x 2.50.92.816.5-20./30)12 x 2.50.93.120.6-26./30)19 x 2.50.93.525.5-31./30)24 x 2.50.93.928.8-36./28)1 x 41.01.57.2-9.0389912(56/28)2 x 41.01.811.8-15./28)3 x 41.01.912.7-16./28)4 x 41.0214.0-17./28)5 x 41.02.215.6-19./28)7 x 41.03.118.2-21./28)1 x 61.01.67.9-9./28)3 x 61.02.114.1-18./28)4 x 61.02.315.7-20./28)5 x 61.23.617.5-22./26)1 x 101.21.89.5-11.9962308(80/26)3 x 101.23.319.1-24./26)4 x 101.23.420.9-26./26)5 x 101.23.622.9-29./26)1 x 161.21.910.8-13./26)3 x 161.23.521.8-27./26)4 x 161.23.623.8-30./26)5 x 161.23.926.4-33./26)1 x251.42.012.7-15./26)4 x 251.44.128.9-36./26)5 x 251.44.432.0-40./26)1 x 351.42.214.3-17./26)3 x 351.44.129.3-37./26)4 x 351.44.432.5-41./26)5 x 351.44.737.0-45./26)1 x 501.62.416.5-20./26)4 x 501.64.837.7-47./26)5 x 501.65.140.0-50.8240040502/0(356/24)1 x 701.62.618.6-23.367210902/0(356/24)4 x 701.65.242.7-54.0268848303/0(485/24)1 x 951.82.820.8-26.091214053/0(485/24)4 x 951.85.948.4-61.0364863204/0(614/24)1x 1201.8322.8-28.6115217464/0(614/24)4 x 1201.8653.0-66.MCM(765/24)1 x 15023.225.2-31.MCM(765/24)4 x 15026.458.0-73.MCM(944/24)1 x 1852.23.427.6-34.MCM(944/24)4 x 1852.26.864.0-80.MCM(1221/24)1x 2402.43.530.6-38.323.42956500MCM(1221/24)4x 2402.47.072.0-90. x 3002.63.633.5-41. x 4002.83.8--4500-1x
Other supplier products
|
|
N2XCY |
German Standard Industrial Cables N2XCYApplication and DescriptionIn indoor installation,Website:, in cable ducts outdoor and underground for power... |
|
|
[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS |
250V [FA-] TTYS,Website:, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUC... |
|
|
Flame Retardant CAT5e CWB/SWB/SWA Armoured Data Cables PVC Sheath |
Flame Retardant CAT5e CWB/SWB/SWA Armoured Data CablesCAT5e U/UTP4P24 CWB/SWB/SWACAT5e F/UTP4P24 CWB/SWB/SWACAT5e SF/FTP4P24 CWB/SWB/SWAApplication... |
|
|
H05V-K |
Industrial Cables H05V-KApplication and DescriptionThese insulated wires are determined for installation to tde inside of apparatus as well as for ... |
|
|
450/750V LSZH Sheathed, Screened (2-4cores) |
450/750V LSZH Sheathed,Website:, Screened (2-4cores) Application:The cables are mainly used in power stations, mass transit underground passenger s... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |