XLPE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Multitriple)

XLPE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multitriple)RE-2X(St)H 90°C / 300 VSTANDARDSBasic design to EN 50288-7APPLICATIONInstrument cable minimizes noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations.Flame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)***EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Sunlight ResistanceUL 1581 section 1200Oil Resistance**ICEA S-73-532Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.VOLTAGE RATING300VCABLE CONSTRUCTIONConductor:Annealed copper solid or plain copper stranded to IEC 60228 Class 2.Insulation:Extruded cross-linked XLPE compound, EN 50290. 2-29.Triple:Three conductors twisted to form a tripleLay-up:Triples laid up in layers of optimum pitchSeparator:Polyester tapeOverall Screen:Aluminium/polyester tape with tinned copper drain wire, 0.5mm2Outer Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.COLOUR CODEInsulation:Black / White / Red, continuously numbered on white core(1, 2..)for multitriples.Outer Sheath:Black or blue for intrinsically safe systemsPhysical AND THERMAL PROPERTIESTemperature Range During Operation (Fixed State):-30°C – +90°CTemperature Range During Installation (Mobile State):-5°C – +50°CMinimum Bending Radius:7.5 X Overall DiameterCONSTRUCTION PARAMETERSCable CodeRE-2X(St)HNo. of Triples x3xCross SectionNominal Insulation ThicknessNominal Outer Sheath ThicknessNominal Overall DiameterApprox. WeightNo.x3xmm2mmmmmmkg/km0.5mm2 , Multi-stripleRE-2X(St)H 2T0.52x3x0,500.350.98.491RE-2X(St)H 4T0.54x3x0,500.351.09.8123RE-2X(St)H 5T0.55x3x0,500.351.010.8155RE-2X(St)H 6T0.56x3x0,500.351.012.1185RE-2X(St)H 8T0.58x3x0,500.351.113.1221RE-2X(St)H 10T0.510x3x0,500.351.114.7275RE-2X(St)H 12T0.512x3x0,500.351.115.2316RE-2X(St)H 16T0.516x3x0,500.351.217.4414RE-2X(St)H 20T0.520x3x0,500.351.219.1508RE-2X(St)H 24T0.524x3x0,500.351.320.95940.75mm2 , Multi-stripleRE-2X(St)H 2T0.752x3x0,750.380.99.3114RE-2X(St)H 4T0.754x3x0,750.381.010.9163RE-2X(St)H 5T0.755x3x0,750.381.012.0199RE-2X(St)H 6T0.756x3x0,750.381.113.7245RE-2X(St)H 8T0.758x3x0,750.381.114.7296RE-2X(St)H 10T0.7510x3x0,750.381.216.7366RE-2X(St)H 12T0.7512x3x0,750.381.217.3423RE-2X(St)H 16T0.7516x3x0,750.381.319.7555RE-2X(St)H 20T0.7520x3x0,750.381.321.7681RE-2X(St)H 24T0.7524x3x0,750.381.423.78021.0mm2 , Multi-stripleRE-2X(St)H 2T1.02x3x10.41.010.4135RE-2X(St)H 4T1.04x3x10.41.011.9202RE-2X(St)H 5T1.05x3x10.41.013.2251RE-2X(St)H 6T1.06x3x10.41.115.0303RE-2X(St)H 8T1.08x3x10.41.116.1379RE-2X(St)H 10T1.010x3x10.41.218.4461RE-2X(St)H 12T1.012x3x10.41.219.0544RE-2X(St)H 16T1.016x3x10.41.321.7717RE-2X(St)H 20T1.020x3x10.41.424.1880RE-2X(St)H 24T1.024x3x10.41.426.110481.3mm2 , Multi-stripleRE-2X(St)H 2T1.32x3x1,30.451.011.5175RE-2X(St)H 4T1.34x3x1,30.451.113.4258RE-2X(St)H 5T1.35x3x1,30.451.114.8318RE-2X(St)H 6T1.36x3x1,30.451.216.9387RE-2X(St)H 8T1.38x3x1,30.451.218.1474RE-2X(St)H 10T1.310x3x1,30.451.320.7589RE-2X(St)H 12T1.312x3x1,30.451.321.4695RE-2X(St)H 16T1.316x3x1,30.451.424.4918RE-2X(St)H 20T1.320x3x1,30.451.527.11124RE-2X(St)H 24T1.324x3x1,30.451.629.613361.5mm2 , Multi-stripleRE-2X(St)H 2T1.52x3x1,50.451.011.9191RE-2X(St)H 4T1.54x3x1,50.451.114.0287RE-2X(St)H 5T1.55x3x1,50.451.115.4355RE-2X(St)H 6T1.56x3x1,50.451.217.6432RE-2X(St)H 8T1.58x3x1,50.451.319.1540RE-2X(St)H 10T1.510x3x1,50.451.321.6672RE-2X(St)H 12T1.512x3x1,50.451.422.5779RE-2X(St)H 16T1.516x3x1,50.451.525.71031RE-2X(St)H 20T1.520x3x1,50.451.628.61265RE-2X(St)H 24T1.524x3x1,50.451.731.11508Note : Other conductor sizes & core configurations are available upon request.Electrical PROPERTIESConductor Area Sizemm 20.50.751.01.31.5Insulation thickness (nominal)mm0.350.380.40.450.45Conductor resistance (20°C)Ω/km36.725.018.514.212.3Insulation resistance (20°C)MΩ.km(Min.)5000Mutual Capacitance (1 kHz)up to 4 trples pF/m(Max.above 4 trples pF/m(Max.InductancemH/km(Max.)1L / R (ratio) (max.)μH/Ω2525254040Operating voltageV300Test Voltage UrmsCore to CoreV1500Core to ScreenV1500

Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Belden8178
Belden8178 Multipair Individually and Overall Screened Cables-Belden Equivalent 8178ApplicationsThese cables have individually screened pairs laid up in a foi...
3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant (Radial Field)
3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant (Radial Field) 3.8/6.6kV,Website:, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Radial Field)Applicatio...
150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation Control Cables (Multicore)
150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation Control Cables (Multicore) 50/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore)ApplicationThese armour...
Type SHD-GC Three-Conductor Round Portable Power Cable, CPE Jacket 8kV ICEA S-75-381
Type SHD-GC Three-Conductor Round Portable Power Cable, CPE Jacket 8kV ICEA S-75-381 Type SHD-GC Three-Conductor Round Portable Power Cable,Website:, CPE Jacket 8kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for a...
450/750V LSZH Sheathed, Screened (2-4cores)
450/750V LSZH Sheathed, Screened (2-4cores) 450/750V LSZH Sheathed,Website:, Screened (2-4cores) Application:The cables are mainly used in power stations, mass transit underground passenger s...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes