.

600/1000V LSZH Sheathed, AL. Wire Armoured (single Core)

600/1000V LSZH Sheathed,Website:, AL. wire Armoured (single core) Application:The cables are mainly used in power stations, mass transit underground passenger systems,airports, petrochemical plants, hotels, hospitals, and high-rise buildings.Standard:Basic design to BS 7211FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING600/1000VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound. Inner sheath(optional): LSZH Compound Armouring(optional): Aluminium WireOuter Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation colour as per bs7671with earth conductorwithout earth conductor2Cores-Brown,Blue3CoresYellow/Green,Brown,BlueBrown,Gray,Black4CoresYellow/Green,Brown,Gray,BlackBrown,Gray,Black,Blue5CoresYellow/Green,Brown,Gray,Black,BlueBrown,Gray,Black,Blue,Blackabove 5 CoresYellow/Green,Black NumberedBlack Numberedsheath colour: BlackPhysical AND THERMAL PROPERTIES Temperature range during operation: Max.90°C250°C in short-circuit for 5s max. Minimum bending radius: 8 x Overall Diameter (unarmoured cable) 10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter Of StrandsNominal Insulation ThicknessInsulated, Non-SheathedArmouredNominal Overall DiameterApprox. WeightDiameter Under ArmourArmour Wire DiameterNominal Overall DiameterApprox. WeightNoxmm2No./mmmmmmkg/kmmmmmmmkg/km1x1.57/0.530.7648----1x2.57/0.670.76.463----1x47/0.850.77.078----1x67/1.040.77.5105----1x107/1.350.78.5151----1x167/1.700.79.5211----1x257/2.140.911.2315----1x357/2.520.912.4416----1x5019/1.781.x7019/2.141.11679215.41.2521.59601x9519/2.521.118106817.31.2523.412401x12037/2.031.220132519.11.625.916501x15037/2.251.422162721.11.627.919701x18537/2.521.624.4202123.21.630.123901x24061/2.251.727.5261726.21.633.230401x30061/2.521.830.3325228.81.635.837901x40061/2.852.033.9413132.72.040.947901x50061/3.202.237.6517536.22.044.658801x630127/2.522.442.4663140.62.049.274001x800127/2.852.647.3841245.72.555.795001x1000127/3.202.852.41053050.62.561.011750Electrical PROPERTIESConductor Operating Temperature : 90°C Ambient Temperature : 30°CUnarmoured  Current-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1...87.96.86.86.86.8104.74.74.7444162.92.92.92.52.52.5rxzrxzrxzrxzrxz251.851.850.311.901.850.1901.851.600.271.651.6000.1651.6001.6000.1901.600351.351.350.291.351.350.1801.351.150.251.151.1500.1551.501.1500.1801.150500.991.000.291.050.990.1801.000.870.250.900.8600.1550.8700.8600.1800.870700.680.700.280.750.680.1750.710.600.240.650.5900.1500.6100.5900.1750.620950.490.510.270.580.490.1700.520.440.230.500.4300.1450.4500.4300.1700.4601200.390.410.260.480.390.1650.430.350.230.420.3400.1400.3700.3400.1650.3801500.320.330.260.430.320.1650.360.290.230.370.2800.1400.3100.2800.1650.3201850.250.270.260.370.260.1650.300.230.230.320.2200.1400.2600.2200.1650.2802400.190.210.260.330.200.1600.250.1850.220.290.1700.1400.2200.1700.1650.2403000.1550.1750.250.310.160.1600.220.1500.220.270.1400.1400.1950.1350.1600.2104000.120.1400.250.290.130.1550.200.1250.220.250.1100.1350.1750.1100.1600.1955000.0930.1200.250.280.1050.1550.1850.1000.220.240.0900.1350.1600.0880.1600.1806300.0720.1000.250.270.0860.1550.1750.0880.210.230.0740.1350.1500.0710.1600.1708000.056---0.0720.1500.170---0.0620.1300.1450.0590.1550.16510000.045---0.0630.1500.165---0.0550.1300.1400.0500.1550.165Armoured  Current-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable tray or Reference Method 13 [free air] )Reference Method 12 (free air)In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.3 cables 3-phase a.c. trefoil touchingone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.mm2AAAAAAAAAVoltage Drop (Per Amp Per Meter)Conductor crosssectional area2 cables d.c.2 cables singlephase a.c.3 or 4 cables three-phase a.c.2 cables singlephase a.c.3 or 4 cables, 3-phase a.c. touchingReference Method 1 & 11 (touching)Reference Method 1, 11 & 12 (in trefoil touching)Reference Method 1 & 11 (Flat touching)In ductsIn groundIn ductsIn ground123456789mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/mrxzrxzrxz700.670.680.200.710.590.170.620.60.250.650.800.700.700.61950.490.510.1950.550.440.170.470.460.240.520.650.530.560.461200.390.410.1900.450.350.1650.390.380.240.440.550.430.480.371500.310.330.1850.380.290.1600.330.310.230.390.500.370.430.321850.250.270.1850.330.230.1600.280.260.230.340.450.310.390.272400.1950.210.1800.280.180.1550.240.210.220.300.400.260.350.233000.1550.170.1750.250.1450.1500.210.170.220.280.370.240.320.214000.1150.1450.1700.220.1250.1500.1950.1600.210.270.350.210.300.195000.0930.1250.1700.210.1050.1450.1800.1450.200.250.330.200.280.186300.0730.1050.1650.1950.0920.1450.1700.1350.1950.240.300.190.260.178000.0560.0900.1600.1900.0860.1400.1650.1300.1800.230.280.180.240.1610000.0450.0920.1550.1800.0800.1350.1550.1250.1700.210.260.170.220.15

Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Harmonized Code Industrial Cables H05BQ-F H07BQ-F(NGMH11YÖ)
Harmonized Code Industrial Cables H05BQ-F H07BQ-F(NGMH11YÖ) Harmonized Code Industrial Cables H05BQ-F/H07BQ-F(NGMH11YÖ)Application and DescriptionThese cables are used for medium mechanical stress in dry,Web...
PE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Single Pair)
PE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Single Pair) PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Single Pair)RE-2Y(St)H 90°C / 300VSTANDARDSBasic design to EN 50288...
Type 209 1.1 To 11KV To AS/NZS 1802
Type 209 1.1 To 11KV To AS/NZS 1802 Type 209 1.1 to 11KV to AS/NZS 1802ApplicationsType 209 series cable is mainly used as a flexible feeder to machinery,Website:, more suitable as a ...
LiFY
LiFY German Standard Industrial Cables LiFY Application and DescriptionLiFY is highly flexible lead wire,Website:, it can be used as super flexible insu...
Type SHD-GC Three-Conductor Round Portable Power Cable, CPE Jacket 8kV ICEA S-75-381
Type SHD-GC Three-Conductor Round Portable Power Cable, CPE Jacket 8kV ICEA S-75-381 Type SHD-GC Three-Conductor Round Portable Power Cable,Website:, CPE Jacket 8kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for a...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes